YC8_Mainte_E.pdf - 第93页

A-1 Appendix 1. Specifications 1.1 Air regulator unit T he air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the front lower left panel. A digital pressure gauge is pr…

100%1 / 98
Appendix
Appendix
Contents
1. Specifications A-1
1.1 Air regulator unit A-1
1.2 Power connection terminals A-2
1.3 Connection between machines A-3
1.3.1 PREVIOUS INTERFACE connector A-3
1.3.2 NEXT INTERFACE connector A-4
2. Warranty A-5
A-1
Appendix
1. Specifications
1.1 Air regulator unit
The air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the
front lower left panel. A digital pressure gauge is provided on the front left of the machine. The air pressure
must be set to the optimum level.
Source air connector
Air regulator unit
Air supply/shutoff
switch (valve)
Air pressure regulator
Air pressure setting
for machine
Pressure-drop
detection level
53A01-N8-00
n
Supply air pressure
This is the pressure of the source air supplied to the machine. Before setting the air pressure with the air regulator, make
sure that this supply air pressure is in the following optimal range.
YC8 : 0.45MPa
n
Air pressure setting and pressure-drop detection level
Air pressure setting for machine (upper reading) : 0.40MPa to 0.41MPa
Pressure-drop detection level (lower reading) : 0.33MPa
n
Digital pressure gauge
Shows the supply air pressure (upper reading) and pressure-drop detection level (lower reading). A normal pressure value
is shown in green, and a pressure value lower than the pressure-drop detection level is shown in red.
n
Air supply/shutoff switch (valve)
Turning this switch to the right shuts off air supply and exhausts air that remains inside the machine.
n
Source air connector
Prepare an air hose with an inner diameter of at least 8mm having a 40SH socket (Nitto Koki, or equivalent), and connect
it to this connector. Use dry, clean air passed through an air filter.
A-2
Appendix
1.2 Power connection terminals
The power connection terminals are located inside the lower right panel on the front of the machine. Connect
the power cable leads as shown below to the L1, L2, L3 and ground terminal (PE) on the power terminal block.
n
Power supply specifications
Model name Power Frequency Power capacity
YC8 3-phase AC 200/208/220/240/380/400/416V (±10%) 50/60Hz 2.2KVA
Power input terminals
Power cable
Power input terminals
L1
L2
L3
PE
Main breaker
53A02-N8-00
Fork-tongue crimp terminal
Fork-tongue crimp terminal
Power cable example
L1
L2
L3
PE
L=100mm
53A03-N8-00
c

Use a power cable whose conductor cross-section area is greater than 2.5mm
2
.
w
WARNING

