A-2 Appendix 1.2 Power connection terminals T he power connection terminals are located inside the lower right panel on the front of the machine. Connect the power cable leads as shown belo w to the L1, L2, L3 and ground…

100%1 / 98
A-1
Appendix
1. Specifications
1.1 Air regulator unit
The air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the
front lower left panel. A digital pressure gauge is provided on the front left of the machine. The air pressure
must be set to the optimum level.
Source air connector
Air regulator unit
Air supply/shutoff
switch (valve)
Air pressure regulator
Air pressure setting
for machine
Pressure-drop
detection level
53A01-N8-00
n
Supply air pressure
This is the pressure of the source air supplied to the machine. Before setting the air pressure with the air regulator, make
sure that this supply air pressure is in the following optimal range.
YC8 : 0.45MPa
n
Air pressure setting and pressure-drop detection level
Air pressure setting for machine (upper reading) : 0.40MPa to 0.41MPa
Pressure-drop detection level (lower reading) : 0.33MPa
n
Digital pressure gauge
Shows the supply air pressure (upper reading) and pressure-drop detection level (lower reading). A normal pressure value
is shown in green, and a pressure value lower than the pressure-drop detection level is shown in red.
n
Air supply/shutoff switch (valve)
Turning this switch to the right shuts off air supply and exhausts air that remains inside the machine.
n
Source air connector
Prepare an air hose with an inner diameter of at least 8mm having a 40SH socket (Nitto Koki, or equivalent), and connect
it to this connector. Use dry, clean air passed through an air filter.
A-2
Appendix
1.2 Power connection terminals
The power connection terminals are located inside the lower right panel on the front of the machine. Connect
the power cable leads as shown below to the L1, L2, L3 and ground terminal (PE) on the power terminal block.
n
Power supply specifications
Model name Power Frequency Power capacity
YC8 3-phase AC 200/208/220/240/380/400/416V (±10%) 50/60Hz 2.2KVA
Power input terminals
Power cable
Power input terminals
L1
L2
L3
PE
Main breaker
53A02-N8-00
Fork-tongue crimp terminal
Fork-tongue crimp terminal
Power cable example
L1
L2
L3
PE
L=100mm
53A03-N8-00
c

Use a power cable whose conductor cross-section area is greater than 2.5mm
2
.
w
WARNING


A-3
Appendix
1.3 Connection between machines
To exchange signals such as board request and operation status with the downstream or upstream machine, the
"NEXT INTERFACE" and "PREVIOUS INTERFACE" connectors located on the rear of the machine are used. The
"NEXT INTERFACE" connector connects to the downstream machine, and the "PREVIOUS INTERFACE"
connector connects to the upstream machine such as a loader. In the case of standard right-to-left flow, the
PREVIOUS INTERFACE connector is located inside the lower right cover on the rear of the machine while the
NEXT INTERFACE connector is located inside the lower left cover on the rear of the machine.
1.3.1 PREVIOUS INTERFACE connector
When the following three conditions are satisfied, the PREVIOUS INTERFACE circuit in the machine allows the
next board to be carried in. (ADVANCED GATE is selected.)
1. Machine is ready for carrying in a board. (BUSY OUT: ON)
2. Board carry-in signal is input from the upstream machine. (BA IN [N01007A1] : ON)
3. Auto operation signal is input from the upstream machine. (UR IN [N01007A3] : ON)
n
NOTE
When the auto operation running signal (UR IN) from the loader turns off during board carrying-in, the machine
temporarily stops carrying in the board.
When the board being carried in is detected by the entrance sensor, the BUSY OUT signal turns off.
Carrying in the board is nished when both the BUSY OUT and BA IN turn off.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
7
12
4
8
1
14
11
3
BUSY OUT
(T01000E4)
+24V
+24V
LR OUT
(T01000E7)
UR IN
(N01007A3)
BA IN
(N01000421)
Carrying-in input
Carry-out request
output
Auto operation running
output
Auto operation running
input
LE OUT
(T0100031)
Waiting for board between
machines input
I/O BOARD
PREVIOUS INTERFACE circuit
PREVIOUS INTERFACE of machineUpstream machine
PREVIOUS INTERFACE
connector
AMP 206043-1
(14-pin receptacle)
53A04-N8-00
n
Board transfer signal specifications (PREVIOUS INTERFACE)
Pin No. Signal name Address I/O specifications Signal specifications
BUSY OUT T01000E4 Relay contact output
Board carrying-in signal output
2 BUSY OUT T01000E4 Relay contact output
3 +24V Input common (+24V)
Board carry-out signal input
4 BA IN N01007A1 Voltage input
5 NC (with dummy pin) (Prevents incorrect insertion.)
6 to 8 NC
9 +24V Input common (+24V)
Auto operation running signal input
10 UR IN N01007A3 Voltage input
11 LR OUT T01000E7 Relay contact output
Auto operation running signal output
12 LR OUT T01000E7 Relay contact output
13 LE OUT T0100031 No-voltage output
Waiting for board between machines
signal input
14 LE OUT T0100031 No-voltage output