S25 circuit.pdf - 第60页
3 Circ uit d iagrams 60 0033681 2-020 102TD3 Power su pply stru cture ( Sh. 2 of 4) 2 4 SMD-Placement System Siplace S23 Product stat us Doc. statu s Fun cti on st atus transformer as as V2 8 Connecti ons must not pr otr…

3 Circuit diagrams 59
00336812-020102TD3 Power supply structure (Sh. 1 of 4)
=
Datum
Gepr.
Norm
Bearb.
Sheet
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Sh.
+
PL EA1 E
270.0
370.0
65
6A
F11
57
1
4333
F10
10A
20A
54
K1
34
13 23X5
1
10A
0
F9
2
10A
170.0
66
MP1
0
2
16A
0
F2
4
4
1
0
5
0
2
1
0
2
0
2
1
0
2
l=130mm
535.0
470.0
14 24X6
F4
PE
l=146mm
l=160mm
66
0
1
F1
24
85.0
NNN
5
N
Q1
31
X1 X3
1
L1
2
F8
l=146mm
l=164mm
0.0
167.0
73.0
10A 10A
1
5834 44
K2
F6
65
K3
0
3
10A
2
1
X200
2
6
0.0 21.2
6.0
Channel 1
PE PEPE
N
14X6X2 X4 X2 X4L244
42
65.0
0
F3
10A
2
1
0
0
5
6
6
X1 X3 X5
F7
0
2
1
53
F5
Channel 2
Power
L2
16A
3
0
On
Ready
L1 13 23 33 43
This lateral freedom of movement is needed to achieve optimum passage through the front panel.
It must be possible to move the main switch up to 2mm to the left/right on the top-hat rail.
The X200 terminals on the upper top-hat rail must be seated flush on the right, against the stop.
Note!
1234567
FF
E
C
B
A
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
TS35 - Top-hat rail
678
A
8
12345
B
C
D
E
Leh
Leh
Deu
02
01
02
02.09.98
23.01.98
04.12.98
04.12.98
Werner
#
Power supply structure
00336812-020102TD3
D
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
1
4

3 Circuit diagrams 60
00336812-020102TD3 Power supply structure (Sh. 2 of 4)
2
4
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
transformer
as as
V2
8
Connections must not protrude
123 678
12 7
V5
F
E
Single-phase
transformer
Fix both cable ducts
with additional rivets
the cable harness to the machine
31
12 22 32
14 24 34
2 T1
4 T2
01
13 23 33
11 21
Cables must not protrude over the top edge of the frame!
SIEMENS
Leh
Leh
Deu
02
01
02
03.09.98
23.01.98
04.12.98
04.12.98
Werner
#
Power supply structure
00336812-020102TD3
V1
8
A
F
Place K4 contactor flush on the right!
Join cables together with cable ties.
K4
N
-5% 120
PE
B
C
D
E
A1
21 NC
5 L3
Point for fixing
over the terminals!
6 T3
22 NC
1 L1
3 L2
0.0
Three-phase
=
Datum
Gepr.
Norm
Bearb.
Sheet
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Sh.
+
PL EA1 E
0.0
T2
- 535.0
T1
24
45
170.0
+5%
5
150 0
8
V4
V3
D
6
24
34
spacer
230 230
C
B
A
Attach end clamp

3 Circuit diagrams 61
00336812-020102TD3 Power supply structure (Sh. 3 of 4)
3
4
SMD-Placement System Siplace S23
Product status
Doc. status
Function status
transformer
L=110mm
304.0
678
123
1
678
E
B
ES 1 2 3 4 5 6 7 8 9 10
Typ 4AV1301-6CT
SIEMENS PLEA1
PLEA1 Serial No.: ...
D
C
B
Serial NO.
484848
105SC
A
400
N
-
F F
E
D
C
A
0V42105
24 230
T2
400 208208
140
PE
400
V1
45
-~
~~
+
400 208400
~
V5
A
10
~
248-5%150230
400
29.5
42
Three-phase transformer
42
+
-
120 +5%N
02
01
02
Deu
Leh
Leh
V4
~
+
~
08
=
Datum
Gepr.
Norm
Bearb.
Sheet
Urspr. Ers. f. Ers. d.NameDatumAenderungZustand
SIEMENS AG
Sh.
+
PL EA1 E
13.02.98
02.09.98
00336812-020102TD3
Power supply structure
#
Werner
04.12.98
04.12.98
V2
~
V3
~
-
A1
Single-phase
A: Identification label Assembly inscription acc. to VA-F-510-001 PL EA
B: Inspection label Test identification for products acc. to guideline VA-F-510-001
Apply the following labels:
Oval cable duct dia.=30mm L=100mm
Edge protection
current limiter
Cable duct dia.=20mm
2345
Inrush
T1
105
119.0
B
Mat.Nr.:00336812-01