ERROR MESSAGES LIST
Ea
Ea00352
Ea00399
Ea00405
Ea00430
Ea00431
Ea00432
Ea00500
Ea00501
Ea00502
Ea00503
Ea00504
Ea00505
Ea00508
ORIGIN IMCOMPLETE
The tray unit pallet is out of the magazine. When you push
[READY], make sure followings.
1. Can you keep on safety for another persons?
2. Have you kept on machine moving area?
3. Have you returned a pallet to magazine?
Manual Tray changer error
No response from Manual Tray changer for more than
10sec.
NO DEFINED DOT WAS FOUND.
The dispense fluid may be in short or the nozzle may be
clogged up.
Head number
Remove cause of this error. Use FILL UP CYLINDER
command in 1/1/D4 RUNNING UTILITY to confirm the
glue is ready in the cylinder.
[Sp.Function] ERROR
This function is NOT available for this machine.
Because in [Position] page of [3/2/A1 SELECT TARGET],
R data of [Locate pin] and [Edge Clamp] is not between -
5 and +5.
Change [Sp.Function] to [NOT USE].
[Sp.Function] ERROR
To use this function, the R data of [Blk Repeat Info.] should
be between -5 and +5.Or change [Sp.Function] to [NOT
USE].
Component data
Name
[Sp.Function] ERROR
A component with its [Pick Angle] to be [0/SIM], should
be located on the front feeder plate.
Or change [Sp.Function] to [NOT USE].
Mount data SpDat[MNTnum_inf0]
Component data
Name
Now reading data. Please wait a moment....
Now reading data. Please wait a moment....
DATA READING ERROR
Failed to read data.
PCB DATA ERROR
Failed to write data.
PCB DATA ERROR
No PCB has been selected. Select PCB by [D1 SWITCH
PCB DATA]
Creating new PCB data now. Please wait a moment.....
<PCB Information> cannot open SUB-WINDOW except
dispense machine.
(meaning)The pallet has been forcibly ejected from the magazine.
(cause)None
(remedy)Press the Emergency Stop button and return the pallet to
the magazine.
(Meaning)During using special function to handle manual tray feeder
automatic exchanging system, the system do not turn on the ready
signal for 10 second.
(Cause)qSpend out of tray.wStuck of tray.eThe power of the sys-
tem is off.rThe air pressure is not supplied for the system.tSome
trouble in the system.
(Remedy)qSupply tray.wAlign the tray.ePower on.rSupply
air.tAdjust the system.
(meaning) Specified position is outside of soft limit.
(cause) Axis cannot move outside of soft limit.
(remedy) Enter correct position.
(Meaning)Although the special function for SIMM/DIMM 8head si-
multaneous picking, is used, 5 degrees or more value is in the R
data of [locate pin position] or [PCB corner], which prevent the spe-
cial function to be used.
(Cause)If the PCB has actually 5 or more degrees on the working
position, this function is not available.
(Remedy)Turn off the special function, or correct the wrong angle
data, or adjust conveyor units so that the PCB angle to be less than
5 degrees.
(Meaning)Although the special function for SIMM/DIMM 8head si-
multaneous picking, is used, 5 degrees or more value is in the R
data of [block repeat data], which prevent the special function to be
used.
(Cause)If the Block has actually 5 or more degrees on the working
position, this function is not available.
(Remedy)Turn off the special function, or correct the wrong angle
data.
(meaning)This indicates that the PCB data is being read.
(cause)None
(remedy)Please wait.
(meaning)This indicates that the PCB data is being read.
(cause)None
(remedy)Please wait.
(meaning)An error occurred in reading the data
(cause)The file may have been destroyed.
(remedy)The relevant data could not be read. If there is a backup
copy, copy the data from the backup and use it.
(meaning)An error occurred in writing the PCB data.
(cause)The hard disk is full, or there is a problem with the disk.
(remedy)First check the condition of the disk If there is a problem
with the number of files, delete any unnecessary files and then try
writing the data again.
(meaning)Please specify the PCB data first.
(cause)Another command was issued before specifying which PCB
is to be edited.
(remedy)First use the edit target switching command to specify the
file to be edited.
(meaning)This is an indication that new PCB data is being created.
(cause)None
(remedy)Please wait.
(meaning) Specified position is outside of soft limit.
(cause) Even though sub-window does not open, command has
been used in PCB information to open sub-window, or [F4] key has
been used.
(remedy) None
Ea00509
Ea00510
Ea00511
Ea00512
Ea00515
Ea00516
Ea00517
Ea00518
Ea00530
Ea00531
Ea00532
Ea00533
Ea00534
Ea00535
No more PCB files can be edited (Max 10 files).
In this menu, repeated patterns can be defined. Press
[ENTER] key to enter this menu. Press any other key to
abort.
In this menu, dispense actions can be defined. Press [EN-
TER] key to enter this menu. Press any other key to abort.
In this menu, point-fiducial, local-fiducial and 4-point-fi-
ducial can be defined. Press [ENTER] key to enter this
menu. Press any other key to abort.
CAUTION: Ready to load database information into Se-
lected records. Any adjusted parameters in the selected
records will be overwritten.
Push the [SPACE] key to execute.
Push the [ESC] key to cancel this operation.
CAUTION: Ready to save selected records of compo-
nent or mark data into the Database.
(Reverse of usual way)
Push the [SPACE] key to execute.
Push the [ESC] key to cancel this operation.
CAUTION: Ready to save all records of component or
mark data into the Database. (Reverse of usual way)
Push the [SPACE] key to execute.
Push the [ESC] key to cancel this operation.
Production History data will be deleted.
Press the [SPACE] key to execute, or any other key to
abort.
No Data base number is specified. If you would like to
perform a 'Set from Database', then please input a Data
base number in the SUB WINDOW.
0 : means that the DataBase number is not specified.
CAUTION : Ready to load Component information from
machine Data base to ALL components in the PCB com-
ponent data base. Any adjusted parameter in the current
PCB component data base will be lost. Push the [SPACE]
key to execute. Push the [ESC] key to cancel this opera-
tion.
CAUTION: Amount of data exceeded the limit for auto-
running. Reduce the number of data. Amount of 'Mount
Data', 'Component Info.', 'Mark Information', 'Block Re-
peat', 'Fiducial Mark', 'PreDispense' and 'DotDispense'
cannot exceed 2560. And 'Component Inf' cannot exceed
255.
ERROR:PRD HISTORY does not exist on the disk. Copy
to Machine first.
ERROR: If copy selected lines or insert 1 line, the end of
data will be over the maximum number of lines.
ERROR: Replace command cannot be executed in this
condition. Now Replace function is for MOUNT informa-
tion. If you want to execute Replace function, set current
window as MOUNT information.
(meaning)An attempt was made to edit 10 or more PCB files at
once.
(cause)A large number of PCB files were opened without saving
previous files first.
(remedy)Save PCB data files which have already been opened,
before opening another file.
(meaning)This notifies the user that editing of block repeat data is
beginning.
(cause)None
(remedy)Press the Enter key.
(meaning)This notifies the user that the editing screen for adhesive
dispensing is being accessed.
(cause)None
(remedy)Press the Enter key.
(meaning)This notifies the user that the editing screen for point fi-
ducial data is being accessed.
(cause)None
(remedy)Press the Enter key.
(Meaning)This is warning before the [SET FROM DATABASE] com-
mand for 2 or more component data at once.
(Cause)Operation to execute [SET FROM DATABASE] command
for 2 or more component data had been done.
(Remedy)Press [SPACE] to execute command, or press[ESC] to
cancel the command.
(Meaning)This is warning before reverse set of 2or more compo-
nent data into the database at once.
(Cause)The operation to execute reverse set of 2or more compo-
nent data into the database had been done.
(Remedy)Press [SPACE] to execute command, or press[ESC] to
cancel the command.
(Meaning)This is warning before reverse set of all component data
into the database at once.
(Cause)The operation to execute reverse set of all component data
into the database had been done.
(Remedy)Press [SPACE] to execute command, or press[ESC] to
cancel the command.
(Meaning)This is warning to initialize the production history data.
(Cause)Going to initialize the production history.
(Remedy)Press [SPACE] to execute command, or press[ESC] to
cancel the command.
(meaning) The database information setting command was issued,
or the F7 key pressed, without specifying the database number.
(cause)Same as above.
(remedy)Enter any value other than 0 for the database number on
the sub-screen (the right-hand screen).
(meaning)This notifies the user that all of the component data will
be overwritten by the database information.
(cause)None
(remedy)To execute the process, press the Space key. To cancel it,
press the ESC key.
(meaning)Too much PCB data exists.
(cause)Data has been copied or additions made, so that the result-
ing data exceeds the specifications.
(remedy)Delete any data which is not being used, or if the amount
of data exceeds the specifications, distribute the data between sev-
eral machines, so that data for any one machine is within the speci-
fications.
(meaning)There is no production history information.
(cause)An attempt was made to view the production history infor-
mation for a PCB for which there is no such information yet.
(remedy)With the YVOS2, read the production history information
from the machine. With the machine, there is no production history
information until PCBs have actually been produced, so do not try
to open the information.
(meaning) Too many data to exceed maximum data numbers.
(cause)If copying had executed, result is over of limited data num-
bers.
(remedy)Quit of this operation, or decrease data numbers that you
have selected.
(meaning)Replace command is not effective for this window.
(cause)Replace command can be executed in MOUNT information

Ea -12
ERROR MESSAGES LIST
Ea
Ea00540
Ea00541
Ea00542
Ea00543
Ea00544
Ea00545
Ea00546
Ea00549
Ea00550
Ea00551
Ea00552
Ea00555
Ea00556
Ea00557
Ea00558
Ea00559
Ea00560
Processing Data. Please wait a moment.....
CAUTION: Now going insert data.
But, it is dangerous for not fitting data, because data num-
ber will be changed. Push the [ENTER] key to execute.
Push the other key to cancel this operation.
CAUTION: Now going delete empty data area. But, it is
dangerous for not fitting data, because data number will
be changed. Push the [ENTER] key to execute. Push the
other key to cancel this operation.
ERROR: Following copying is impossible.
1. Between PCB data and all data
2. Between Component data and the other data
3. Between Mark data and the other data
4. Except among Mount data, PreDispense data, and
DotDispense data
5. Except among Block Repeat data, Point Fiducial data,
and Local Bad data
CAUTION: Note data is exist. If execute, block conver-
sion is not available. Push the [ENTER] key to execute.
Push the other key to cancel this operation.
ERROR: This command is available to Mount-Data, Parts-
Data, and DotDispens-Data only. Push the [ENTER] key
to cancel this operation.
CAUTION: Data not found. After reference, The data was
not found.
ERROR:
This machine doesn't have production log data.
Please confirm whether using this function.
Teach 2nd position for AVERAGE TEACHING.
[SHIFT+F10]: to continue next (max 4)
[F10] : to decide value
Teach 3rd position for AVERAGE TEACHING.
[SHIFT+F10]: to continue next (max 4)
[F10] : to decide value
Teach last position for AVERAGE TEACHING. You can-
not teach more than four positions.
[F10] : to decide value
Please teach another side position on the diagonal line
for DISTANCE TEACHING.
[F10] : to decide value
EMG.STOP ON or ORIGIN INCOMPLETE. You cannot
do teaching or tracing.
TEACH & TRACE condition is not ready.
Select TEACH UNIT, SPEED, and FID. CORRECTION
at [B0 TEACH,TRACE CONDITION].
X-Comp. Amount or Y-Comp. Amount is less than 1.
You cannot do DISTANCE TEACHING.
X-TrayAmount or Y-TrayAmount is less than 1. You can
not do DISTANCE TEACHING.
Pallet-StartNo has an illegal value.
You can not do teaching or tracing.
(meaning)This notifies the user that data is being processed.
(cause)None
(remedy)Please wait.
(meaning)This is a warning that an attempt has been made to in-
sert or copy component data items.
(cause)None
(remedy)This is a warning message. To proceed with the changes,
press the Enter key.
(meaning)This is a warning that an attempt has been made to de-
lete filler component data items.
(cause)None
(remedy)This is simply a warning message. To proceed with the
changes, press the Enter key.
(meaning)The copying is impossible.
(cause)You did impossible copying.
(remedy)Do possible copying.
Be careful to execute the delete or copy command. If "NOTE" data
is lost, it is not available to back the original data from block con-
verted data.
This command is available to Mount-Data, Parts-Data, and
DotDispens-Data only.
After reference, The data was not found.
“Yes” has been set for error log in machine configuration, so error
log is created when production is executed.
(meaning)This notifies the user that teaching is in progress.
(cause)None
(remedy)None
(meaning)This notifies the user that teaching is in progress.
(cause)None
(remedy)None
(meaning)This notifies the user that teaching is in progress.
(cause)None
(remedy)None
(meaning)This notifies the user that the system is in the middle of
distance teaching.
(cause)None
(remedy)None
(meaning)Conditions have not been met when teaching or tracing
is attempted.
(cause)An attempt was made to initiate teaching or tracing during
an emergency stop, or before the origin point is reached.
(remedy)First cancel the emergency stop, and if a return to the
origin position has not been carried out, execute that command.
(meaning)Conditions for teaching or tracing have not been speci-
fied.
(cause)Same as above.
(remedy)Specify the teaching unit and other information with the
D0 teaching/tracing conditions before carrying out the teaching or
tracing.
(meaning)A value of 1 or less has been entered for the component
quantity in the component quantity information.
(cause)Same as above.
(remedy)None
(meaning)An attempt was made to initiate tray teaching with a value
of 1 or less entered for the tray quantity in the tray quantity informa-
tion.
(cause)Same as above.
(remedy)None
(meaning)The starting pallet number is not correct.
(cause)The starting pallet number which has been input is not cor-
rect.
(remedy)First input the correct pallet number and then try the op-
eration again.(remedy)Change current window to MOUNT informa-
tion.
Ea00561
Ea00562
Ea00563
Ea00564
Ea00565
Ea00570
Ea00571
Ea00572
Ea00573
Ea00574
Ea00590
Ea00601
The fiducial recognition has not been completed although
the TEACH,TRACE CONDITION is set to use FIDUCIAL
CORRECTION.
Select FIDUCIAL CORRECTION to be ON and do the
recognition of mark again, or FIDUCIAL
CORRECTION to be OFF, at [B0 TEACH,TRACE CON-
DITION].
Type of fiducial recognition is not selected. Please set
the item of PCB Fiducial or BLOCK Fiducial to "Use" in
the PCB information.
Mark data is not ready. Please prepare correct mark data.
All coordinates of the fiducial mark are (0.0).
Fiducial correction does not work with this condition.
Please set correct coordinates.
Undefined TrayChanger had been selected as 'Feeder
Type'. Correct 'Feeder Type' data.
ALIGNMENT ERROR
Setting of the alignment module is not correct. One of the
following could cause this error:
• Alignment module is not specified.
• Alignment module is not equipped.
• Alignment module cannot handle this component.
• This component is too large to alignment module.
ALIGNMENT TYPE ERROR
1. Component Database
Alignment type is 'undefined'.
2. Mark Database
Marktype is 'Not Specify'.
PARAMETER-SEARCH ERROR
Failure of parameter-search of the component!
Please check body-parameter of the component, for ex-
ample 'body size x'.
PCB DATA ERROR
Illegal component shape data or component data is not
defined.
COMPONENT DATA ERROR
It is impossible to execute "DRAW THE SHAPE(CMP)".
Please check next.
(1) "Alignment Module" is "Non".
(2) "Alignment Type" is "Undefined".
(3) Alignment module cannot handle this component.
MACHINE DATA ERROR
Failed to read machine data.
DATA ERROR
The number of used feeder exceeds your possession.
Feeder group PNEUMATIC Type
Feeder type 8mm tape
(meaning) Although fiducial correction has been set to “Yes” in Teach,
Trace condition, no fiducial marks have been recognized.
(cause) Same as ìMeaningî.
(remedy) Set value once more in Teach, Trace condition, and select
“Yes” for fiducial correction. Then run fiducial mark recognition func-
tion.
(meaning)The type of fiducial correction has not set yet.
(cause)The fiducial item must be set "Use" to PCB, BLOCK, or both.
(remedy)Set the fiducial item in the PCB information to PCB, BLOCK,
both.
(meaning)There is no mark data for the fiducial recognition func-
tion.
(cause)Same as above.
(remedy)The data for the mark number specified by the fiducial mark
parameter in the PCB information needs to be defined as the rel-
evant number in the mark information. Check to see that this data
has been defined.
(meaning)All of the fiducial mark coordinates are set to 0.
(cause)No coordinate data has been entered for the fiducial marks.
(remedy)Input the correct coordinates.
(meaning)The tray changer specified in the component data does
not exist on this machine.
(cause)The setting indicates use of a tray changer which does not
exist on this machine.
(remedy)Correct the setting for the feeder type.
(meaning)The setting for the recognition unit is wrong.
(cause)The recognition unit has not been specified; a recognition
unit which does not exist has been specified; recognition of that
component is not possible with the recognition unit that has been
specified; or the component is too large to use laser recognition.
(remedy)Edit the setting so that it is correct.
(meaning)Either the correction type or the mark function has not
been specified.
(cause)If the component database is being used, the type of cor-
rection has not been specified. If the mark database is being used,
the mark function has not been specified.
(remedy)With a component database, specify the correction type.
With a mark data base, specify the mark function correctly.
(meaning)An error occurred in optimizing the component param-
eters.
(cause)Component optimization was not possible.
(remedy)First check to see if basic data such as the component
shape is correct, and then try the function again.
(meaning)The settings for the component shape information are
inappropriate, and the component data cannot be transferred to vi-
sion data.
(cause)There is inappropriate data among the component shape
information.
(remedy)Go back to the editing screen and correct the data.
(meaning)It is impossible to execute [ DRAW THE SHAPE (CMP) ]
command.
(cause) 1."Alignment Module" is "Non".
2."Alignment Type" is "Undefined"
(remedy)Please set these parameters.
(meaning)Failed to read machine data.
(cause)Incorrect size of machine data of some machine data files
are lost.
(remedy)Copy machined data from back-up disk.
(meaning)The number of feeders specified for use in the data cre-
ation function exceeds the number available, so the setup is impos-
sible.
(cause)
(remedy)If the number of feeders being used is wrong, use the con-
figuration mode to correct the feeder quantity information. If there
are actually too few feeders, buy more.

Ea -13
ERROR MESSAGES LIST
Ea
Ea00602
Ea00603
Ea00604
Ea00605
Ea00610
Ea00611
Ea00620
Ea00621
Ea00622
Ea00623
Ea00624
Ea00625
Ea00642
Ea00643
DATA ERROR
The number of used nozzle exceeds your possession.
Machine 1
Nozzle_type 2
DATA ERROR
The number of component data exceeds system limit.
Machine 2
DATA ERROR
The number of mount data exceeds system limit.
Machine 2
DATA ERROR
The nozzle is not distributed to head.
Machine SM120
•Some nozzles cannot pick the interfering component.
Check the nozzle type of each components.
•Luck of nozzle number. Check the nozzle number and
head spec. inf..
Failed to access feeder quantity data file.
Failed to access nozzle quantity data file.
DATA ERROR
No component data exists.
Machine 2
PCB CUK93001
Component 150
DATA ERROR
No fiducial data exists for the mount data.
Machine 2
PCB CUK93001
Mount 765
Fiducial 1
DATA ERROR
No mark data exists.
Machine 2
PCB CUK93001
Mark 1
DATA ERROR
No badmark data exists for the mount data.
Machine 2
PCB CUK93001
dispense 765
Badmark 1
DATA ERROR
No fiducial data exists for the dispense data.
Machine 2
PCB CUK93001
dispense 765
Fiducial 1
DATA ERROR
No badmark data exists for the dispense data.
Machine 2
PCB CUK93001
dispense 765
Badmark 1
Dispense machine is not exist.
Failed to open dispense information.
(meaning)The number of nozzles planned for use exceeds the num-
ber available for processing.
(cause)The number of nozzles used to manufacture the data cur-
rently being planned is not enough for the actual processing.
(remedy)If the setting for the number used in processing is wrong,
correct it in the machine configuration. If there are actually too few
nozzles, purchase more, or use the YV112 to create data for the
places where nozzles are to be secured and used.
(meaning)The number of component data exceeds the specifica-
tions.
(cause)Components assigned to the specified machine exceed the
specifications.
(remedy)Shift some of the component data assigned to that ma-
chine to another machine.
(meaning)The number of mounting data exceeds the specifications
for that machine.
(cause)Same as above.
(remedy)Set up the specified components on another machine.
(meaning)In no-nozzle change machine, nozzle is not distributed
to each head.
(cause)Some component is too big size to interfere to nearest
nozzle(head).
(remedy)Check the component size and nozzle type. Check the
number of nozzle and the setting of head spec. inf..
(meaning)An error occurred in accessing the data file containing
the number of feeders to be used.
(cause)There is a problem with the hard disk
(remedy)Try creating the data again from the beginning. If it cannot
be recovered, contact the manufacturer.
(meaning)An error occurred in accessing the data file containing
the number of feeders to be used.
(cause) There is a problem with the hard disk
(remedy)Try creating the data again from the beginning. If it cannot
be recovered, contact the manufacturer.
(meaning)There is no component data.
(cause)Same as above.
(remedy)Create the specified component data.
(meaning)There is no fiducial data.
(cause)Same as above.
(remedy)Create the specified fiducial data.
(meaning)There is no mark data.
(cause)Same as above.
(remedy)Create the mark data.
(meaning)There is no badmark data.
(cause) Same as above.
(remedy)Create the specified badmark data.
(meaning)There is no fiducial data.
(cause)Same as above.
(remedy)Create the specified fiducial data.
(meaning)There is no badmark data.
(cause)Same as above.
(remedy)Create the specified badmark data.
Please select the "Exist" of Dispense Head in MCH_CONFIG.
Fail to make the temporary file.
Ea00645
Ea00647
Ea00648
Ea00649
Ea00650
Ea00651
Ea00653
Ea00658
Ea00660
Ea00661
Ea00662
Ea00663
Ea00664
CAUTION: Now going to convert the data from "Exec" to
"Note" in Mount, Block repeat, Local fiducial and Local
badmark. So, "Exec"data will be deleted. Push the [EN-
TER] key to execute. Push the [ESC] key to cancel this
operation.
"Note" data need to execute the convert from block con-
verted data to original data is not exist.
Machine YV112
CAUTION: Amount of Mount data that executed block
conversion exceeded 2500. Amount of data exceeded
the limit for auto-running. Reduce the number of data.
Amount of 'Mount Data", 'Component Info,' , 'Mark Infor-
mation', 'Block Repeat', 'Fiducial Mark', 'PreDispense' and
'DotDispense' cannot exceed 2560. Push the [ENTER]
key to continue. Push the [ESC] key to cancel this opera-
tion.
There is only one "Exec" data in Block repeat.
PCB DATA ERRORNFORMATION ERROR
No alignment module for the component.
Machine 2
PCB CUK93001
Component 1
PCB DATA ERROR Feeder Information
No dump station for the component. Or the table of the
dumpstation is different from the one of the component.
Machine 2
PCB CUK93001
Component 1
DOT DISPENSE SORT TIMEOUT ERROR
Dispense sort was interrupted by time out error. Dispense
sort was finished, but it is contained the data that stopper
may interfere with other dispense data.
Please check the following:
•Illegal Diameter, Stopper and Pitch data of the nozzle
spec.
COMMAND ERROR
1. [ADJUST ASSISTANT] command is not available for a
component with positive "FixCmpRef."
2. [DRAW THE SHAPE(CMP)] command is not available
for a component with positive "FixCmpRef."
DATA ERROR
Failed to quote component details from its Data Base.
Component 150
specifies an illegal database number.
CheckPoint: DataBase Number
DATA ERROR
Failed to quote mark details from its Data Base.
Mark 150
specifies an illegal database number.
CheckPoint: DataBase Number
DATA ERROR
Failed to set up component or mark information from
Database. MAIN WINDOW should be component info. or
mark info.
Or indicated database may not exist.
Or failed to set up component or mark information into
Database. The indicated record may be protected by pass
word level.
FILE ERROR
Failed to read PCB Data.
DATA ERROR
Failed to set up Fixed feeders at its position.
Component 150
specifies an impossible set position.
The component that feeder position is "Teaching" is ex-
ist.
Change the "FeederPosition" into "Automatic".
Change the "MOUNT DATA CONDITION" into "FEEDER
MOVE".
This is a warning message.
Check the existence of "Note" data in Mount, Block repeat, Local
fiducial, Local badmark.
Calculated mount data over 2500. So check and decrease the
amount of Mount, Block repeat, Local fiducial and Local badmark
within 2560.
This PCB data is not for block. Block data need more than two "Exec"
data in Block repeat.
(meaning)Suitable alignment module for the component is not
equipped on the machine.
(cause)There is an error in the setting in the alignment module for
the component or the component must be mounted by the other
machine.
(remedy)Correct the erroneous setting.
(meaning)Though the component must be dumped to the dump
station, the machine is not equipped with a dump station properly.
(cause)There is an error in the setting in the dump way for the com-
ponent or the machine data. Or the table of the dump station is
different from the table where the component is fixed.
(remedy)Correct the erroneous setting.
(meaning)Dispense sort was interrupted by timeout error.
(cause)Illegal Diameter, Stopper and Pitch data of the nozzle spec.
(remedy)Please check the nozzle spec data.
(meaning)These commands are not available for component with
positive "FixCmpRef.".
(remedy)Use these commands to components data in PCB
[STATIC_COMPONENTS].
(meaning)An error occurred when setting data from the database.
(cause)There is no information in the database corresponding to
the specified database number.
(remedy)Use the database list command to check the existing da-
tabase numbers, and specify an existing number.
(meaning)An error occurred when setting data from the database.
(cause)There is no database corresponding to the specified data-
base.
(remedy)Use the database list command to check the existing da-
tabase numbers, and specify an existing number.
(meaning) Data cannot be set from database.
(cause) An attempt was made to use database setting function on
screen other than component information or mark information
screen.
(remedy) Use [F3] key to switch to component information or mark
information screen.
(meaning)An error occurred in reading the PCB data.
(cause)ÅgPCB data with an asterisk (*) was selected; a machine
which has not been registered was selected; or the PCB data has
been destroyed.
(remedy)In the first two cases, correct the operation. In the last case,
copy the data from the backup disk.
(meaning)An error occurred in attaching the fixed feeder because
of the data created.
(cause)Another fixed feeder already exists in that position, so there
is no space to attach the specified feeder.
(remedy)Find the feeder which is interfering with the fixed feeder,
and remove it, or delete the specification of the fixed feeder which is
causing the problem. If the component that feeder position is
"TEACHING", change to "AUTOMATIC" and execute the optimiza-
tion.