YAMAHA errer code-a.pdf - 第9页
Ea - 9 ERROR MESSAGES LIST Ea Ea00246 Ea00247 Ea00248 Ea00249 Ea00250 Ea00251 Ea00260 Ea00261 Ea00262 Ea00270 Ea00271 Ea00272 Ea00273 PCB DA TA ERROR This component body size is too big.gh. So this compo- nent is cannot …

Ea -8
ERROR MESSAGES LIST
Ea
Ea00204
|
Ea00205
Ea00206
Ea00207
Ea00220
Ea00221
Ea00222
Ea00223
Ea00230
Ea00231
Ea00232
NOZZLE STATION ERROR
There is no nozzle present for next sequence. Please
check nozzle station data.
Head No. 2
Station No. 11
NOZZLE STATION ERROR
There is more than one nozzle for next sequence. Please
check sensors of the nozzle station and insert the appro-
priate nozzle(s).
Head No. 2
Station No. 11
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
BACKLIGHT POSITION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. and pull up no.2 head to up-end, push
down no.1 head to lower pos.
4. In case the step 1-3 had not solved problem, Please
move backlight to right position by CHANGE BACKLIGHT
command.
NOZZLE CHANGE ERROR
Now, head is picking the component. Head can't change
the nozzle.
OPERATION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. Check the safety of head, nozzles,
nozzle station.
4. In case the step 1-3 had not solved problem, Please
ensure safety by manual.
NOZZLE STATION CLAMPING ERROR
Unable to clamp nozzles in the nozzle station.
Correct the condition of the nozzle station.
4-Point Fiducial Data Error
Fiducial No.5
6
Setting of [Type] is not correct. Please set like this,
No. 5 --> [4Local-M]
No. 6 --> [4Local-S]
4-Point Fiducial Data Error
Fiducial No.5
6
Fiducial No.5
6
Setting of [Mark] is not correct. Please set same number.
4-Point Fiducial Data Error
Fiducial No.5
6
Distance between point and another point is too short.
Please set this distance more than 5(mm). Please set
coordinates of 4-point again.
(meaning)The nozzle intended for use is not in the nozzle station.
(cause)The nozzle which is planned for use has not been specified
in the nozzle station information.
(remedy)Check the settings in the nozzle station information.
(meaning)The nozzle station contains more than one of the same
nozzle.
(cause)Two of the same nozzle have been specified in the nozzle
station information.
(remedy)Check the nozzle station information.
(meaning)A head number of 3 or higher has been specified in the
mounting data for a mounter which has only two heads.
(cause)A head number of 3 or more has been specified.
(remedy)Change the head number in the placing data to 1 or 2.
(meaning)Vision recognition is specified with head 2.
(cause)With this machine, vision recognition cannot be carried out
using head 2.
(remedy)Change the head number to 1, or change to laser recog-
nition.
(meaning)The backlighting illumination is dangerously positioned.
(cause)When an attempt was made to change nozzles, the nozzles
could not be changed because the position of the backlighting illu-
mination was dangerous.
(remedy)Check to see that all of the nozzles are in the nozzle sta-
tion, and that the sensor reacts to all of the nozzles in the nozzle
station. Next, press the Emergency Stop button and move head 2
to its upper end and head 1 below the backlighting illumination
Then use the backlighting illumination movement command to move
the backlighting illumination to the right.
(meaning)The nozzle cannot be replaced because a component
has been picked up.
(cause)Two causes are possible: the head vacuum is on, or the
head vacuum is on and a component has been detected by the
vacuum level sensor.
(remedy)Remove the component from the nozzle or turn off the
head vacuum.
Accident happened for YV-120 machine Nozzle changing is failed.
According to the message and recover this accident
(meaning)Although the upper plate of the nozzle station slides and
two sensor for both edge (only single side for YVL80) detect the
actual action of the plate, at least 1 sensor do not response to the
command to slide the plate.
(cause)qPlate is mechanically stuck. The position or the sensitivity
of the sensor is not adjusted.
(remedy)Repair the sliding plate, or adjust the sensor.
Please set fiducial data according to "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Ea00233
Ea00234
Ea00235
Ea00236
Ea00237
Ea00238
Ea00239
Ea00240
Ea00241
Ea00242
Ea00243
Ea00244
Ea00245
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
distance between one point and one side of quadrilater-
als is less than 5(mm). Please set coordinates of 4-point
again.
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
there is interior angle which is over 180 degree. sage.
Please set coordinates of 4-point again.
4-Point Fiducial Data Error
Fiducial No.5
6
It is impossible to use this fiducial number which is se-
lected in this Mount Data, because this data is [4Local-
S]. Please use [4Local-M] Fiducial number of 4-point fi-
ducial.
4-Point Fiducial Data Error
Fiducial No.4
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
PCB DATA ERROR
Mount data No.4
Fiducial data No.6
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
4-Point Fiducial Data Errorpe Error
Mount data No. 6
Fiducial data No. 2
3
Coordinate of mount point is out of range of 4-point-fidu-
cial. to use this function in Please don't use this 4-point
fiducial for this mount point.
Data Warning
The piece of block that you defined in PCB Information is
different from piece of local badmark.
In this case, machine cannot count Block Numbers in
Production History. If you want to count Block Numbers,
change number of block in PCB Information.
PCB DATA ERROR
No mark data available for the local fiducial. Or the mark
data is not for fiducial.
Mount Data 1
Mark Data 2
PCB DATA WARNING
Height of component is out of range for "Multi Cam".
Component Data 2
It may be impossible to recognize this component by us-
ing "Multi.Cam". It is necessary to check whether this
component is able to be recognized by using "Multi.Cam"
in [ADJUST ASSISTANT]. To continue "Data-Check",
press any key.
MARK DATA WARNING
Templet image can't be downloaded to the vision.
•Did you create templet image of target mark?
•Don't you make too many mark data in one PCB?
•Don't you want to use too many kind of mark?
PCB DATA ERROR
Effective data was not found. There is no data to execute.
Use 'PASS'.
PCB DATA ERROR
There is no mark pattern data. Some pattern matching
function is used for fiducial mark, but it has no pattern
matching data. This data was made by executing of [Ad-
just Assistant] in Mark Information.
PCB DATA ERROR
This component body height is too high. So this compo-
nent is cannot recognize by equipped camera.
Mount Data 10
Component Data 5
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Set same number of block in PCB Information as total local badmark
number.
(meaning)The mark data for the specified not an fiducial does not
exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)It may be impossible to recognized this component by
using "Multi.Cam" because height of this component is out of range
for "Multi.Cam"
(remedy)Please check recognition of this component in [ADJUST
ASSISTANT].
(meaning) No effective data in the PCB data.
(remedy) Use "PASS".
(meaning) There is no data for pattern matching.
(remedy) Make data for pattern matching of fiducial mark in mark
information.
(meaning) This component is too high for its height.
(remedy) Check camera coordinate data.

Ea -9
ERROR MESSAGES LIST
Ea
Ea00246
Ea00247
Ea00248
Ea00249
Ea00250
Ea00251
Ea00260
Ea00261
Ea00262
Ea00270
Ea00271
Ea00272
Ea00273
PCB DATA ERROR
This component body size is too big.gh. So this compo-
nent is cannot recognize by equipped camera.
Mount Data 10
Component Data 5
PCB DATA ERROR
"Mount Action" reserved component number is "Fine
Type", but fine mode reserved head is "Impossible".
Mount data 10
Head number 5
Please reserve component number not "Fine Type", etc.
COMPONENT DATA ERROR
Feeder Type for this component was not defined. Specify
the feeder type data in Component Info.
Mount Data 12
Component Data 3
COMPONENT DATA ERROR
Feeder Position must be "Teaching" or "Relative" for stick
feeder component. Input Feeder Pos_X,Y:
In case "Teaching", from the datum of machine origin.
In case "Relative", from the datum of 8mm tape feeder
pickup position.
Component data 3
COMMUNICATION ERROR
Failure of communicating with LOADER. One of the fol-
lowing could cause this error:
q LOADER or UNROADER is turned off power.
w LOADER or UNROADER is in emergency stop.
e LOADER or UNROADER is in auto-running.
r LOADER or UNROADER has already received PCB
width data after power-on.
If you don't want to repeat communicating with LOADER
Please push [TAB] keys.
If you want to repeat communicating with LOADER Please
push other keys.
DUMP STATION DATA ERROR
The feeder number used for dump station is not defined.
It must not be 0. Please confirm it.
DUMP STATION DATA ERROR
The feeder number used for dump station is not suitable.
In case of SM112, if this number for A-table is defined
more than 101, then this error will happen. Please con-
firm it.
DUMP STATION DATA ERROR
The X,Y position of dump station is not suitable. All heads
must be reach on this position, but the current coordi-
nate is out of it. In case of SM112, dump station may be
set about from 16 to 40 feeder location number. Please
correct X,Y coordinate of dump station.
PCB DATA ERROR
There is no dispense head for dot dispensing. Check the
head type and nozzle type in 3-2-A1-[Head Offset].
Dot Dispense data 11
PCB DATA ERROR
Dot dispensing position is outside moving area.
Dot Dispense data 3
Axes X
Checking dot dispensing data. Please wait a moment.......
Dot Dispense data 4
Block number 3
PCB DATA ERROR
Local badmark position of dispense data is outside mov-
ing area.
Dispense data 4
Local Badmark data 3
Axes X
(meaning) This component is too big for its height.
(remedy) Check camera coordinate data.
(meaning) The head "FineMode" is "Impossible " cannot act by
"FineType".
(cause) Reserved head is FineMode Impossible, but reserved com-
ponent is "FineType".(remedy) Please do one of following ways.
• Change headnum Finemode Possible.
• Change component not Finetype.
• Change component data other type
• Change "FineMode" "Possible".
(meaning) Feeder Type was not defined yet.
(cause) It seems that component package parameter was changed
after feeder type was defined. So, feeder type was changed to "Not
Defined"
(remedy) Select right feeder type.
(meaning) Feeder position is set to "Automatic" but this is a stick
feeder component.
(cause) Stick feeder must set its feeder set position to "Teaching"
or "Relative".
(remedy) Set right setting for Feeder Position (Teaching or Rela-
tive). And input Feeder Pos_X,Y parameter.
In case "Teaching", input from the datum of machine origin
In case "Relative", input from the datum of 8mm tape feeder pick
up position
(meaning) Failure of communicating with LOADER.
(cause) Cause is shown in "Error Message".
(remedy)Please remove cause.
This message is not "Error Message".
(meaning)
(cause)None
(remedy)None
(meaning)Feeder number for dump station is 0.
(cause)Feeder number for dump station must be more than 1.
(remedy)Please set number again.
(meaning)Feeder number for dump station is 0.
(cause)There is no dump station on the table which feeder for a
component is attached.
(remedy)If no dump station, please abort to use. Please change
feeder location on same table to dump station. Please set more
than 1 in feeder number for dump station.
(meaning)Feeder number for dump station is 0.
(cause)Because all heads must be reached on this coordinate, but
current pos. is out of it.
(remedy)Please change the position of dump station, and change
the coordinate again.
(meaning)Illegal dispense head was defined in dot dispense data.
(cause)The head does not exist, or the head number is not dis-
pense head.
(remedy)Please input right head number.
(meaning)X,Y position of Dot Dispense data is out of moving area.
(cause)The position is out of software limit.
(remedy)Please set right X, Y position or set right head number.
(meaning)Data check about dot dispensing data is being now car-
ried on.
(cause)This is not error message.
(remedy)Please wait until data check finish.
(meaning)Local badmark position defined in Dot dispense data is
out of moving Area.
(cause)Local badmark position is out of software limit.
(remedy)Please input right local badmark position.
Ea00274
Ea00275
Ea00276
Ea00277
Ea00278
Ea00279
Ea00280
Ea00281
Ea00282
Ea00283
Ea00284
Ea00285
Ea00286
Ea00287
PCB DATA ERROR
There is no local badmark data for the dot dispense.
Dispense Data 4
Local Badmark Data 3
PCB DATA ERROR
There is no mark data of local badmark available for the
dot dispense data.
Dot Dispense Data 4
Local Badmark data 3
Mark data 5
PCB DATA ERROR
No local badmark data is set to "Note" for executable dot
dispense data. During production, "Note" data is ignored.
So if you want to use local badmark function, set this "
Exec". If not, set "0" for BadMk in dot dispensing data.
Dot Dispense Data 4
Local Badmark Data 3
4-Point Fiducial Data Error
Dot Dispense Data No 4
Fiducial Data No. 3
It is impossible to use this Fiducial number which is se-
lected in this Dot Dispense Data, because this data is
[4Local-S]. Please use [4Local-M] Fiducial number of 4-
point fiducial.
PCB DATA ERROR
Dot Dispense Data No. 4
Fiducial data No. 3
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
PCB DATA ERROR
No fiducial data available for the dot dispense local fidu-
cial.
Dot Dispense data 4
Fiducial data 3
PCB DATA ERROR
No mark data available for the dot dispense local fidu-
cial.
Dot Dispense data 10
Fiducial data 5
Mark data 2
Checking pre dispensing data.
Please wait a moment.......
Pre Dispense data 4
Block number 3
PCB DATA ERROR
Pre dispensing position is outside moving area.
Pre Dispense data 3
Axes X
PCB DATA ERROR
There is no dispense head for pre dispensing.
Pre Dispense data 11
Head number 4
PCB DATA ERR
It is impossible to use "Point Fiducial" for Dispense. Please
check the mount data or fiducial data.
Dot Dispense data 5
Fiducial data 3
PCB DATA ERR
Illegal unit for pre dispensing. Defined unit for that head
is out of range for adequate unit.
Pre Dispense data 5
Head number 3
Unit 30
PCB DATA ERR
Illegal unit for dot dispensing. Defined unit for that head
is out of range for adequate unit.
Dot Dispense data 4
Head number 2
Unit 70
DOT STATION PITCH ERR
Dot station pitch either X direction or Y direction must be
set "0". Please check the dot station pitch X,Y.
(meaning)Local badmark data for dot dispense data does not ex-
ist.
(cause)Local badmark data have not defined in local badmark in-
formation yet.
(remedy)Please define local badmark data, if you use this function.
(meaning)There is not mark data for local badmark.
(cause)The mark data of Local badmark data for dot dispense have
not defined.
(remedy)Please define mark data in mark information for local
badmark of dot dispense data.
(meaning)The local badmark data of the dot dispense data is "Note"
data.
(cause)Local badmark that is "Note" is ignored during in running
condition.
(remedy)Please input "Exec" data of local badmark for dot dispense
data.
(meaning)The fiducial number of dot dispense data is "4Local-S"
data.
(cause)"4Local-S" data is not for setted in fiducial number of dot
dispense data.
(remedy)Please set "4Local-M" number.
(meaning)The fiducial number of dot dispense
(cause)"Note" data is ignored in running.
(remedy)Set "Exec" from "Note".
(meaning)There is no fiducial data for dot dispense data.
(cause)The fiducial number of dot dispense has not defined yet.
(remedy)Please make fiducial data
(meaning)There is no mark data for fiducial data of dot dispense
data.
(cause)The mark data was not made yet.
(remedy)Please make mark data of fiducial of dot dispense, or if
you have already prepared mark data, set that mark number.
(meaning)Data check about pre dispensing data is being now
carryed on.
(cause)This is not error message.
(remedy)Please wait until data check finish.
(meaning)X,Y position of Pre Dispense data is out of moving area.
(cause)The position is out of software limit.
(remedy)Please set right X, Y position or set right head number.
(meaning)Illegal dispense head was defined in pre dispense data.
(cause)The head does not exist, or the head number is not dis-
pense head.
(remedy)Please input right head number.
Please don't use "Point Fiducial" for Dispense.
Non adequate dispensing unit was defined. Please set head num-
ber "0", to select head automatically, or input adequate value for
dispensing unit that is defined in NOZZLE-SPEC Information.
Non adequate dispensing unit was defined. Please set head num-
ber "0", to select head automatically, or input adequate value for
dispensing unit that is defined in NOZZLE-SPEC Information.
(meaning)DOT STATION PITCH ERR
(cause)Dot station pitch either X direction or Y direction must be
set "0".
(remedy)Please check the dot station pitch X,Y.

Ea -10
ERROR MESSAGES LIST
Ea
Ea00288
Ea00289
Ea00290
Ea00300
Ea00301
Ea00302
Ea00303
Ea00304
Ea00305
Ea00306
DOT STATION MAX MATRIX NUMBER ERR
Please set max matrix number to more than 1. Please
check the max matrix number.
DOT STATION DATA ERR
All heads can not be able to reach to dot station. Please
check the dot station position X,Y.
Head number X
Axis X
NOZZLE SPEC DATA ERROR
Failed to read the nozzle spec information. Please pre-
pare correct nozzle spec information. Select this com-
mand by
YVOS2....3-3-[A4 NOZZLE SPEC.INF]-[SM86D Type]
MACHINE.3-1-[A4 NOZZLE SPEC.INF]-[Shift]+[Enter]
Machine SM86D
file NO?\NZL_TIM.STS
Tray unit error : The component is not placed correctly on
the traverser station. If the component is on the station,
please remove it.
Mount data 765
Component data 153
Station 2
Next tray position is for the next pick sequence.
(X= 6 , Y= 3)
Tray unit error : Returned component is not placed cor-
rectly on the traverser station. If the component is on the
station, please remove it.
Mount data 765
Component data 153
Station 2
Tray unit error : Returned component is not placed cor-
rectly on the traverser station. If the component is on the
station, please remove it.
Mount data 765
Component data 153
Pallet 9
Next tray position is for the next pick sequence.
(X= 6 , Y= 3)
Tray unit error : Returned component is not placed cor-
rectly on the traverser station. If the component is on the
station, please remove it.
Mount data 765
Component data 153
Station 2
Next tray position is for the next pick sequence.
(X= 6 , Y= 3)
Tray unit error : Returned component is not placed cor-
rectly on the traverser station. If the component is on the
station, please remove it.
Mount data 765
Component data 153
Station 2
Tray unit error : Returned component is not placed cor-
rectly on the traverser station. If the component is on the
station, please remove it.
Mount data 765
Component data 153
Station 2
Tray unit error : Failed to store the pallet. To start produc-
tion again, please return the pallet to its assigned maga-
zine.
Mount data 765
Component data 153
Pallet 9
(meaning)DOT STATION MAX MATRIX NUMBER ERR
(cause)Please set max matrix number to more than 1.
(remedy)Please check the max matrix number.
(meaning)DOT STATION DATA ERR
(cause)All heads can not be able to reach to dot station.
(remedy)Please check the dot station position X,Y.
(meaning)NOZZLE SPEC DATA ERROR
(cause)Failed to read the nozzle spec information.
(remedy)Please prepare correct nozzle spec information.
(meaning) The tray changer was not able to place the supply com-
ponents on the traverser. If extra parts have been placed on the
specified traverser, remove them.
(cause)The pickup sensor on the station was not able to decide
correctly whether or not there was a component on the traverser.
(remedy) If there are extra components on the traverser, remove
them. If there is no problem with the components, and the sensor
has malfunctioned, re-adjust the sensor.
(meaning)Components which were returned from the main unit
could not be placed correctly on the traverser.
(cause)Components from the main unit were not placed correctly
on the traverser or fell off during transport.
(remedy)If components have fallen off, remove those components.
If the sensor judges that there are components on the traverser
when in actuality there are none, re-adjust the sensor.
(meaning)Components could not be picked up from the tray.
(cause)There were no components on the tray when the attempt
was made to pick them up, or components fell off when being moved
from the tray to the traverser.
(remedy)If components have fallen off, remove those components.
If components have run out, supply more.
(meaning)The external tray changer was not able to place compo-
nents properly on the traverser.
(cause)Components fell off of the external tray changer when be-
ing transported, or the sensor on the traverser judged that there
were no components on the traverser, even though there were.
(remedy)If components have fallen off, remove those components.
Adjust the pickup sensor for the traverser so that it judges correctly
whether or not there are components on the traverser.
(meaning)An error occurred when picking up components from the
traverser.
(cause)Components which should have been on the traverser were
not there, or an attempt was made to pick up components from the
traverser but the pickup head sensor or the traverser sensor was
not able to judge correctly whether there were components on the
traverser.
(remedy)Re-adjust the sensors, or, if there are components which
have fallen off, remove them.
(meaning)An error occurred when unknown component is on the
traverser station
(cause)Reset operation was done when some component is on
the traverser station Or traverser sensor was not able to judge the
existence of component.
(remedy)Please remove the component on the traverser station.
Or re-adjust the sensors of traverser.
(meaning)The pallet could not be housed in the magazine.
(cause)A mechanical problem occurred when the attempt was made
to house the pallet in the magazine.
(remedy)Press the Emergency Stop button and return the pallet to
the magazine manually.
Ea00307
Ea00308
Ea00310
Ea00311
Ea00312
Ea00313
Ea00314
Ea00315
Ea00316
Ea00317
Ea00320
Ea00330
Ea00350
Ea00351
Tray unit error : Failed to pull out the pallet. To start pro-
duction again, please return the pallet to its assigned
magazine.
Mount data 765
Component data 153
Pallet 9
Tray unit error : The hook action was performed incor-
rectly. Please check the following items:
1. Pallet (No. 9) access position.
2. The hook nail.
If the pallet is out of the magazine, then:
1. Make sure to push EMERGENCY STOP ON.
2. Remove the pallet from the stage section.
3. Return the pallet to its magazine.
Tray unit : The tray unit head or traverser station has a
component attached to its nozzle (pad). After removing
the component, please press any key.
Tray unit error : Abort the RESET process. If a pallet is
out of the magazine, please return it to its assigned maga-
zine.
Tray unit : Tray unit is working now! Please wait.....
Tray unit error : The pallet is out of the magazine. Return
the pallet to its assigned magazine.
Tray unit error : The door is open. Please close the door.
Tray unit error : Failed to store the pallet. To start produc-
tion again, please return the pallet to its assigned maga-
zine.
Tray unit error : Failed to pull out the pallet. To start pro-
duction again, please return the pallet to its assigned
magazine.
Tray unit error : The door is open. Please close the door.
Something wrong with door and check one.
Tray unit error : Unknown error
Now, head of machine or tray-changer is picking the com-
ponent. If "SET PALLET" will be executed, component
will drop from head. If you execute "SET PALLET", re-
move component from head and hit [Space] key. If you
cancel "SET PALLET", hit other key.
EMERGENCY STOP ON
The tray unit pallet is out of the magazine. When you push
[READY], make sure followings.
1. Can you keep on safety for another persons?
2. Have you kept on machine moving area?
3. Have you returned a pallet to magazine?
INTERLOCK ERROR
The tray unit pallet is out of the magazine. When you push
[READY], make sure followings.
1. Can you keep on safety for another persons?
2. Have you kept on machine moving area?
3. Have you returned a pallet to magazine?
(meaning)An error occurred when taking the pallet out of the maga-
zine.
(cause)For mechanical reasons, an error occurred when the pallet
was being taken out of the magazine.
(remedy)If the pallet has been ejected from the magazine too
abruptly, press the Emergency Stop button and return it to the maga-
zine manually.
(meaning)The hook did not respond correctly to an Open or Close
instruction.
(cause)The hook has not grasped the pallet at the correct position.
(remedy)Re-insert the hook at the correct position in the pallet, and
start the operation again from the beginning. If the pallet has been
ejected from the magazine too abruptly, however, press the Emer-
gency Stop button and return it to the magazine manually.
(meaning) Component exists in external tray changer which should
not be there.
(cause) Component pickup error by external tray traverser. Traverser
has skipped a component because of incorrect teaching of pickup
position or traverser position, or pickup error has been made by
main head traverser. Possibly, vacuum sensor of external tray
changer head or traverser station is incorrectly adjusted.
(remedy) Check component pickup position, traverser coordinates
on main unit side, and coordinates for traverser station on external
tray changer side. Adjust vacuum sensor of external tray changer
head and vacuum sensor of traverser station.
(meaning)This is a notification that the reset process has been in-
terrupted.
(cause)An interlock emergency stop instruction or similar instruc-
tion has been issued.
(remedy)If a pallet has been forcibly ejected return it to the maga-
zine.
(meaning)This is a notification that the tray changer is in operation.
(cause)None
(remedy)Please wait.
(meaning)The pallet has been forcibly ejected from the magazine.
(cause)Same as above.
(remedy)Return the pallet to the magazine.
(meaning)Operation cannot begin because the door of the external
tray changer is open.
(cause)The door of the external tray changer is open.
(remedy)Close the door which is open.
(meaning)An error has occurred in housing the pallet in the maga-
zine.
(cause)None
(remedy)Press the Emergency Stop button and return the pallet to
the magazine manually.
(meaning) An error occurred in taking the pallet out of the maga-
zine.
(cause)None
(remedy)Press the Emergency Stop button and return the pallet to
the magazine manually.
The door that normally closed is open. May be the door is broken.
(meaning)An internal problem has occurred in the tray changer.
(cause)The software version does not match.
(remedy)First, contact the manufacturer and then re-install the soft-
ware.
Remove the component from head of machine or Tray-Changer.
(meaning)The pallet has been forcibly ejected from the magazine.
(cause)None
(remedy)Press the Emergency Stop button, return the pallet to the
magazine, and press the Ready button.
(meaning)The pallet has been forcibly ejected from the magazine.
(cause)None
(remedy)Return the pallet correctly to the magazine and start the