Ea - 8 ERROR MESSAGES LIST Ea Ea00204 | Ea00205 Ea00206 Ea00207 Ea00220 Ea00221 Ea00222 Ea00223 Ea00230 Ea00231 Ea00232 NOZZLE ST ATION ERROR There is no nozzle present for next sequence. Please check nozzle station data…

Ea -7
ERROR MESSAGES LIST
Ea
Ea00177
Ea00178
Ea00179
Ea00180
Ea00181
Ea00182
Ea00183
Ea00184
Ea00185
Ea00186
Ea00187
Ea00189
Ea00190
PCB DATA ERROR
When using component check function, you must pre-
pare some Mark data. But it doesn't exist or is not suit-
able.
Mount data 765
PreDispense data 1
Mark data 1
PCB DATA ERROR
CountOutStop must be same among alternative compo-
nents group.
Mount data 765
Component data 150
PCB DATA ERROR
Specified alternative component doesn't exist.
Mount data 765
Component data 150
PCB DATA ERROR
Feeder type of the component is different from the one of
the fixed component data.
Mount data 765
Component data 150
PCB DATA ERROR
Failed to read the fixed component data.
Mount data 765
Component data 150
PCB DATA ERROR
Specified fixed component doesn't exist.
Mount data 765
Component data 150
PCB DATA ERROR
The number of block repeat data exceeds limitation.
Maximum quantity is 765 .
PCB DATA ERROR
Component Name must be same among alternative com-
ponents group.
Mount data 765
Component data 150
PCB DATA ERROR
Usage of UpdateGroupNo must be same among alterna-
tive components group.
Mount data 765
Component data 150
PCB DATA ERROR
Local badmark position is outside moving area.
Mount data 3
Local Badmark data 5
Axes X
PCB DATA ERROR
No mark data available for the local badmark. Or the mark
data is not for badmark.
Mount data 7
Mark data 2
PCB DATA ERROR
Pickup position is outside moving area for soft landing
motion.
Mount data 765
Component data 150
Axes Z1
PCB DATA ERROR
Mount position is outside moving area for soft landing
motion.
Mount data 765
Component data 150
Axes Z1
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)No mark information for bad marks has been specified in
the pre-dispensing data which contains the check coordinates.
(remedy)Create the mark information for the bad marks.
(meaning)Components which are organized in a series by the al-
ternative component settings do not have the same count stop set-
tings.
(cause)Alternative components in a series have different count stop
settings, so they will either stop or not stop.
(remedy)Standardize the settings.
(meaning)The specified alternative components do not exist.
(cause)There are no alternative components that match the set-
ting.
(remedy)When using alternative components, create data for the
alternative components corresponding to the specified number, or
do not specify alternative components.
(meaning)The feeder type specified in the PCB data is different
from that in the fixed components data.
(cause)A different type of feeder has been specified in the PCB
data from that specified in the fixed components data.
(remedy)Change one setting or the other so that they match.
(meaning)An error occurred when reading the fixed component data.
(cause)No fixed component data file exists in the machine, or the
fixed components data file has been destroyed.
(remedy)Copy the fixed component data from the backup disk.
(meaning)The specified component data does not exist.
(cause)The fixed component data corresponding to the fixed com-
ponent data number specified in the mounting data does not exist.
(remedy)Do not use the fixed component data, or create new fixed
component data.
(meaning)The number of block repeats exceeds the rated limit.
(cause)The specified number of block repeats exceeds the maxi-
mum limit of 512.
(remedy)Specify a number of block repeats that is 512 or less.
(meaning)The names of several components in a series of alterna-
tive components are different.
(cause)The names of all alternative components must be the same.
(remedy)Specify the names of alternative components linked in a
series so that all of the names are the same.
(meaning)In the component data for a series of alternative compo-
nents, there are some data which refer to fixed component data
and some which do not.
(cause)With alternative components, the fixed component data ref-
erences for series component data must be the same.
(remedy)Standardize the settings so that the fixed component data
is either referenced or not referenced for all of the alternative com-
ponent data in the series.
Please input correct position of Local Badmark.
(meaning)The mark data for the specified not an badmark does not
exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)QFP components cannot be picked up using this mount-
ing method because of an incorrect setting in the pickup heights.
(cause)
(remedy)Check the settings for pickup heights.
(meaning)When the QFP mounting method is being used, the
mounting position height is not within the soft limit.
(cause)When the QFP mounting method is being used, the setting
for the mounting position height is outside of the soft limit.
(remedy)Check the setting for the mounting position height.
Ea00191
Ea00192
Ea00193
Ea00194
Ea00195
Ea00197
Ea00198
Ea00199
Ea00200
Ea00201
Ea00202
Ea00203
PCB DATA ERROR
No nozzle to attach to the head.
AxisTable A
Head 2
The number of possessed nozzle may not be enough.
Current nozzles on heads are different from the nozzles
necessary for this PCB.XY TABLE[Upper = Head No.,
Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
Please check each heads equipped with nozzles as
shown below.
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
PCB DATA ERROR
Component will interfere with other nozzles.
Mount data 765
Component data 150
Head 2
PCB DATA ERROR
PCB width is outside moving area.
Axes LW
PCB SIZE ERROR
Width of PCB is out of range.
SpDat[PLTnum_inf0](mm)
<
=
[PCB Width]
<
=
SpDat[PLTnum_inf1](mm)
Please set width of PCB again.
PCB DATA ERROR
No local badmark data is set to "Note" for executable
mounting data. During production, "Note" data is ignored.
So if you want to use local badmark function, set this "
Exec". If not, set "0" for BadMk in mounting data.
Mount Data 6
Local Badmark Data 3
PCB DATA ERROR
The PCB has too many mount data.
NOZZLE CHANGE ERROR
Failed to pick up a nozzle. Please check the sensor of
the nozzle station and adjust height, angle and position
data of the nozzle station.
Head No. 2
Station No. 11
NOZZLE CHANGE ERROR
Failed to store a nozzle. Please check the sensor of nozzle
station and adjust height, angle and position data of the
nozzle station.
Head No. 2
Station No. 11
DOWNLOAD WINDOW DATA ERROR
Failed to download the window data of the laser unit.
Please Power OFF the machine and check the connec-
tion of the laser unit.
NOZZLE STATION ERROR
One or more nozzle(s) are not present on the nozzle sta-
tion. Please check the sensors of the nozzle station and
insert the appropriate nozzle(s).
Head No. 2
(meaning)The specified nozzle cannot be attached to the head.
(cause)Because the setting for the number of nozzles is wrong, there
are not enough nozzles to be attached to the head, or it is not pos-
sible to use more than the current number of nozzles.
(remedy)If the nozzles are available, change the setting for the num-
ber of nozzles In any other case, create PCB data which does not
specify a head using the same nozzles.
(meaning)The nozzles which are currently attached are not the right
combination for the PCB about to be manufactured.
(cause)The wrong combination of nozzles was used when the setup
was changed.
(remedy)Attach the correct nozzles, following the instructions on
the display.
(meaning)This is the display showing the nozzle settings required
for the PCB about to be manufactured. It is not an error message.
(cause)None
(remedy)Check to make sure the nozzles which have been speci-
fied match those displayed before starting production.
(meaning)The component is interfering with the adjacent nozzle.
(cause)Because the component is large, it is interfering with the
nozzle next to it.
(remedy)Create the appropriate data and try again.
(meaning)The PCB width is not within the soft limit.
(cause)An attempt was made to use a PCB which is not within the
specifications, or there is something wrong with the PCB width set-
ting.
(remedy)Check the PCB width setting.
(meaning) PCB width is out of range being used.
(cause) PCB width has not been set within a range of $$$ mm (mini-
mum) to ### mm (maximum).
(remedy) Set PCB width to value within a range of $$$ mm to ###
mm.
If you want to use local badmark function. Set "skip?" parameter
"Exec". If you don't want to use set "0" in mount data
(meaning)The nr. of mount data exceeds limit.
(cause)The nr. of mount data exceeds limit.
(remedy)Delete some mount data. Or delete some skip data in block
repeat and etc.
(meaning)The nozzle could not be picked up.
(cause)The nozzle station sensor may be defective, or the height,
angle, or XY coordinates may not have been correctly adjusted in
the nozzle station information.
(remedy)Adjust the sensor. Also, re-adjust the nozzle position, angle,
and height in the nozzle station information.
(meaning)An error occurred when housing the nozzle.
(cause)The nozzle station sensor may be defective, or the height,
angle, or XY coordinates may not have been correctly adjusted in
the nozzle station information.
(remedy)Check the operation of the nozzle station sensor. Also, re-
adjust the nozzle position, angle, and height in the nozzle station
information.
(meaning)An error occurred when transferring window data to the
laser recognition unit.
(cause)An error occurred in sending the data because of noise or
another factor, or the laser recognition unit has become disconnected
from the I/O board.
(remedy)Check the laser recognition unit connections, and then turn
the power supply off and try running the machine again. Check to
see how often the problem occurs, and contact the manufacturer if
necessary.
(meaning)Several nozzles are produced from the nozzle station of
the specified head.
(cause)The nozzle station sensor may be defective, or several
nozzles have been removed from the nozzle station.
(remedy)Make sure the correct nozzles are stored in the nozzle
station, or check the operation of the nozzle station sensor.

Ea -8
ERROR MESSAGES LIST
Ea
Ea00204
|
Ea00205
Ea00206
Ea00207
Ea00220
Ea00221
Ea00222
Ea00223
Ea00230
Ea00231
Ea00232
NOZZLE STATION ERROR
There is no nozzle present for next sequence. Please
check nozzle station data.
Head No. 2
Station No. 11
NOZZLE STATION ERROR
There is more than one nozzle for next sequence. Please
check sensors of the nozzle station and insert the appro-
priate nozzle(s).
Head No. 2
Station No. 11
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
BACKLIGHT POSITION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. and pull up no.2 head to up-end, push
down no.1 head to lower pos.
4. In case the step 1-3 had not solved problem, Please
move backlight to right position by CHANGE BACKLIGHT
command.
NOZZLE CHANGE ERROR
Now, head is picking the component. Head can't change
the nozzle.
OPERATION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. Check the safety of head, nozzles,
nozzle station.
4. In case the step 1-3 had not solved problem, Please
ensure safety by manual.
NOZZLE STATION CLAMPING ERROR
Unable to clamp nozzles in the nozzle station.
Correct the condition of the nozzle station.
4-Point Fiducial Data Error
Fiducial No.5
6
Setting of [Type] is not correct. Please set like this,
No. 5 --> [4Local-M]
No. 6 --> [4Local-S]
4-Point Fiducial Data Error
Fiducial No.5
6
Fiducial No.5
6
Setting of [Mark] is not correct. Please set same number.
4-Point Fiducial Data Error
Fiducial No.5
6
Distance between point and another point is too short.
Please set this distance more than 5(mm). Please set
coordinates of 4-point again.
(meaning)The nozzle intended for use is not in the nozzle station.
(cause)The nozzle which is planned for use has not been specified
in the nozzle station information.
(remedy)Check the settings in the nozzle station information.
(meaning)The nozzle station contains more than one of the same
nozzle.
(cause)Two of the same nozzle have been specified in the nozzle
station information.
(remedy)Check the nozzle station information.
(meaning)A head number of 3 or higher has been specified in the
mounting data for a mounter which has only two heads.
(cause)A head number of 3 or more has been specified.
(remedy)Change the head number in the placing data to 1 or 2.
(meaning)Vision recognition is specified with head 2.
(cause)With this machine, vision recognition cannot be carried out
using head 2.
(remedy)Change the head number to 1, or change to laser recog-
nition.
(meaning)The backlighting illumination is dangerously positioned.
(cause)When an attempt was made to change nozzles, the nozzles
could not be changed because the position of the backlighting illu-
mination was dangerous.
(remedy)Check to see that all of the nozzles are in the nozzle sta-
tion, and that the sensor reacts to all of the nozzles in the nozzle
station. Next, press the Emergency Stop button and move head 2
to its upper end and head 1 below the backlighting illumination
Then use the backlighting illumination movement command to move
the backlighting illumination to the right.
(meaning)The nozzle cannot be replaced because a component
has been picked up.
(cause)Two causes are possible: the head vacuum is on, or the
head vacuum is on and a component has been detected by the
vacuum level sensor.
(remedy)Remove the component from the nozzle or turn off the
head vacuum.
Accident happened for YV-120 machine Nozzle changing is failed.
According to the message and recover this accident
(meaning)Although the upper plate of the nozzle station slides and
two sensor for both edge (only single side for YVL80) detect the
actual action of the plate, at least 1 sensor do not response to the
command to slide the plate.
(cause)qPlate is mechanically stuck. The position or the sensitivity
of the sensor is not adjusted.
(remedy)Repair the sliding plate, or adjust the sensor.
Please set fiducial data according to "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Ea00233
Ea00234
Ea00235
Ea00236
Ea00237
Ea00238
Ea00239
Ea00240
Ea00241
Ea00242
Ea00243
Ea00244
Ea00245
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
distance between one point and one side of quadrilater-
als is less than 5(mm). Please set coordinates of 4-point
again.
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
there is interior angle which is over 180 degree. sage.
Please set coordinates of 4-point again.
4-Point Fiducial Data Error
Fiducial No.5
6
It is impossible to use this fiducial number which is se-
lected in this Mount Data, because this data is [4Local-
S]. Please use [4Local-M] Fiducial number of 4-point fi-
ducial.
4-Point Fiducial Data Error
Fiducial No.4
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
PCB DATA ERROR
Mount data No.4
Fiducial data No.6
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
4-Point Fiducial Data Errorpe Error
Mount data No. 6
Fiducial data No. 2
3
Coordinate of mount point is out of range of 4-point-fidu-
cial. to use this function in Please don't use this 4-point
fiducial for this mount point.
Data Warning
The piece of block that you defined in PCB Information is
different from piece of local badmark.
In this case, machine cannot count Block Numbers in
Production History. If you want to count Block Numbers,
change number of block in PCB Information.
PCB DATA ERROR
No mark data available for the local fiducial. Or the mark
data is not for fiducial.
Mount Data 1
Mark Data 2
PCB DATA WARNING
Height of component is out of range for "Multi Cam".
Component Data 2
It may be impossible to recognize this component by us-
ing "Multi.Cam". It is necessary to check whether this
component is able to be recognized by using "Multi.Cam"
in [ADJUST ASSISTANT]. To continue "Data-Check",
press any key.
MARK DATA WARNING
Templet image can't be downloaded to the vision.
•Did you create templet image of target mark?
•Don't you make too many mark data in one PCB?
•Don't you want to use too many kind of mark?
PCB DATA ERROR
Effective data was not found. There is no data to execute.
Use 'PASS'.
PCB DATA ERROR
There is no mark pattern data. Some pattern matching
function is used for fiducial mark, but it has no pattern
matching data. This data was made by executing of [Ad-
just Assistant] in Mark Information.
PCB DATA ERROR
This component body height is too high. So this compo-
nent is cannot recognize by equipped camera.
Mount Data 10
Component Data 5
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Set same number of block in PCB Information as total local badmark
number.
(meaning)The mark data for the specified not an fiducial does not
exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)It may be impossible to recognized this component by
using "Multi.Cam" because height of this component is out of range
for "Multi.Cam"
(remedy)Please check recognition of this component in [ADJUST
ASSISTANT].
(meaning) No effective data in the PCB data.
(remedy) Use "PASS".
(meaning) There is no data for pattern matching.
(remedy) Make data for pattern matching of fiducial mark in mark
information.
(meaning) This component is too high for its height.
(remedy) Check camera coordinate data.

Ea -9
ERROR MESSAGES LIST
Ea
Ea00246
Ea00247
Ea00248
Ea00249
Ea00250
Ea00251
Ea00260
Ea00261
Ea00262
Ea00270
Ea00271
Ea00272
Ea00273
PCB DATA ERROR
This component body size is too big.gh. So this compo-
nent is cannot recognize by equipped camera.
Mount Data 10
Component Data 5
PCB DATA ERROR
"Mount Action" reserved component number is "Fine
Type", but fine mode reserved head is "Impossible".
Mount data 10
Head number 5
Please reserve component number not "Fine Type", etc.
COMPONENT DATA ERROR
Feeder Type for this component was not defined. Specify
the feeder type data in Component Info.
Mount Data 12
Component Data 3
COMPONENT DATA ERROR
Feeder Position must be "Teaching" or "Relative" for stick
feeder component. Input Feeder Pos_X,Y:
In case "Teaching", from the datum of machine origin.
In case "Relative", from the datum of 8mm tape feeder
pickup position.
Component data 3
COMMUNICATION ERROR
Failure of communicating with LOADER. One of the fol-
lowing could cause this error:
q LOADER or UNROADER is turned off power.
w LOADER or UNROADER is in emergency stop.
e LOADER or UNROADER is in auto-running.
r LOADER or UNROADER has already received PCB
width data after power-on.
If you don't want to repeat communicating with LOADER
Please push [TAB] keys.
If you want to repeat communicating with LOADER Please
push other keys.
DUMP STATION DATA ERROR
The feeder number used for dump station is not defined.
It must not be 0. Please confirm it.
DUMP STATION DATA ERROR
The feeder number used for dump station is not suitable.
In case of SM112, if this number for A-table is defined
more than 101, then this error will happen. Please con-
firm it.
DUMP STATION DATA ERROR
The X,Y position of dump station is not suitable. All heads
must be reach on this position, but the current coordi-
nate is out of it. In case of SM112, dump station may be
set about from 16 to 40 feeder location number. Please
correct X,Y coordinate of dump station.
PCB DATA ERROR
There is no dispense head for dot dispensing. Check the
head type and nozzle type in 3-2-A1-[Head Offset].
Dot Dispense data 11
PCB DATA ERROR
Dot dispensing position is outside moving area.
Dot Dispense data 3
Axes X
Checking dot dispensing data. Please wait a moment.......
Dot Dispense data 4
Block number 3
PCB DATA ERROR
Local badmark position of dispense data is outside mov-
ing area.
Dispense data 4
Local Badmark data 3
Axes X
(meaning) This component is too big for its height.
(remedy) Check camera coordinate data.
(meaning) The head "FineMode" is "Impossible " cannot act by
"FineType".
(cause) Reserved head is FineMode Impossible, but reserved com-
ponent is "FineType".(remedy) Please do one of following ways.
• Change headnum Finemode Possible.
• Change component not Finetype.
• Change component data other type
• Change "FineMode" "Possible".
(meaning) Feeder Type was not defined yet.
(cause) It seems that component package parameter was changed
after feeder type was defined. So, feeder type was changed to "Not
Defined"
(remedy) Select right feeder type.
(meaning) Feeder position is set to "Automatic" but this is a stick
feeder component.
(cause) Stick feeder must set its feeder set position to "Teaching"
or "Relative".
(remedy) Set right setting for Feeder Position (Teaching or Rela-
tive). And input Feeder Pos_X,Y parameter.
In case "Teaching", input from the datum of machine origin
In case "Relative", input from the datum of 8mm tape feeder pick
up position
(meaning) Failure of communicating with LOADER.
(cause) Cause is shown in "Error Message".
(remedy)Please remove cause.
This message is not "Error Message".
(meaning)
(cause)None
(remedy)None
(meaning)Feeder number for dump station is 0.
(cause)Feeder number for dump station must be more than 1.
(remedy)Please set number again.
(meaning)Feeder number for dump station is 0.
(cause)There is no dump station on the table which feeder for a
component is attached.
(remedy)If no dump station, please abort to use. Please change
feeder location on same table to dump station. Please set more
than 1 in feeder number for dump station.
(meaning)Feeder number for dump station is 0.
(cause)Because all heads must be reached on this coordinate, but
current pos. is out of it.
(remedy)Please change the position of dump station, and change
the coordinate again.
(meaning)Illegal dispense head was defined in dot dispense data.
(cause)The head does not exist, or the head number is not dis-
pense head.
(remedy)Please input right head number.
(meaning)X,Y position of Dot Dispense data is out of moving area.
(cause)The position is out of software limit.
(remedy)Please set right X, Y position or set right head number.
(meaning)Data check about dot dispensing data is being now car-
ried on.
(cause)This is not error message.
(remedy)Please wait until data check finish.
(meaning)Local badmark position defined in Dot dispense data is
out of moving Area.
(cause)Local badmark position is out of software limit.
(remedy)Please input right local badmark position.
Ea00274
Ea00275
Ea00276
Ea00277
Ea00278
Ea00279
Ea00280
Ea00281
Ea00282
Ea00283
Ea00284
Ea00285
Ea00286
Ea00287
PCB DATA ERROR
There is no local badmark data for the dot dispense.
Dispense Data 4
Local Badmark Data 3
PCB DATA ERROR
There is no mark data of local badmark available for the
dot dispense data.
Dot Dispense Data 4
Local Badmark data 3
Mark data 5
PCB DATA ERROR
No local badmark data is set to "Note" for executable dot
dispense data. During production, "Note" data is ignored.
So if you want to use local badmark function, set this "
Exec". If not, set "0" for BadMk in dot dispensing data.
Dot Dispense Data 4
Local Badmark Data 3
4-Point Fiducial Data Error
Dot Dispense Data No 4
Fiducial Data No. 3
It is impossible to use this Fiducial number which is se-
lected in this Dot Dispense Data, because this data is
[4Local-S]. Please use [4Local-M] Fiducial number of 4-
point fiducial.
PCB DATA ERROR
Dot Dispense Data No. 4
Fiducial data No. 3
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
PCB DATA ERROR
No fiducial data available for the dot dispense local fidu-
cial.
Dot Dispense data 4
Fiducial data 3
PCB DATA ERROR
No mark data available for the dot dispense local fidu-
cial.
Dot Dispense data 10
Fiducial data 5
Mark data 2
Checking pre dispensing data.
Please wait a moment.......
Pre Dispense data 4
Block number 3
PCB DATA ERROR
Pre dispensing position is outside moving area.
Pre Dispense data 3
Axes X
PCB DATA ERROR
There is no dispense head for pre dispensing.
Pre Dispense data 11
Head number 4
PCB DATA ERR
It is impossible to use "Point Fiducial" for Dispense. Please
check the mount data or fiducial data.
Dot Dispense data 5
Fiducial data 3
PCB DATA ERR
Illegal unit for pre dispensing. Defined unit for that head
is out of range for adequate unit.
Pre Dispense data 5
Head number 3
Unit 30
PCB DATA ERR
Illegal unit for dot dispensing. Defined unit for that head
is out of range for adequate unit.
Dot Dispense data 4
Head number 2
Unit 70
DOT STATION PITCH ERR
Dot station pitch either X direction or Y direction must be
set "0". Please check the dot station pitch X,Y.
(meaning)Local badmark data for dot dispense data does not ex-
ist.
(cause)Local badmark data have not defined in local badmark in-
formation yet.
(remedy)Please define local badmark data, if you use this function.
(meaning)There is not mark data for local badmark.
(cause)The mark data of Local badmark data for dot dispense have
not defined.
(remedy)Please define mark data in mark information for local
badmark of dot dispense data.
(meaning)The local badmark data of the dot dispense data is "Note"
data.
(cause)Local badmark that is "Note" is ignored during in running
condition.
(remedy)Please input "Exec" data of local badmark for dot dispense
data.
(meaning)The fiducial number of dot dispense data is "4Local-S"
data.
(cause)"4Local-S" data is not for setted in fiducial number of dot
dispense data.
(remedy)Please set "4Local-M" number.
(meaning)The fiducial number of dot dispense
(cause)"Note" data is ignored in running.
(remedy)Set "Exec" from "Note".
(meaning)There is no fiducial data for dot dispense data.
(cause)The fiducial number of dot dispense has not defined yet.
(remedy)Please make fiducial data
(meaning)There is no mark data for fiducial data of dot dispense
data.
(cause)The mark data was not made yet.
(remedy)Please make mark data of fiducial of dot dispense, or if
you have already prepared mark data, set that mark number.
(meaning)Data check about pre dispensing data is being now
carryed on.
(cause)This is not error message.
(remedy)Please wait until data check finish.
(meaning)X,Y position of Pre Dispense data is out of moving area.
(cause)The position is out of software limit.
(remedy)Please set right X, Y position or set right head number.
(meaning)Illegal dispense head was defined in pre dispense data.
(cause)The head does not exist, or the head number is not dis-
pense head.
(remedy)Please input right head number.
Please don't use "Point Fiducial" for Dispense.
Non adequate dispensing unit was defined. Please set head num-
ber "0", to select head automatically, or input adequate value for
dispensing unit that is defined in NOZZLE-SPEC Information.
Non adequate dispensing unit was defined. Please set head num-
ber "0", to select head automatically, or input adequate value for
dispensing unit that is defined in NOZZLE-SPEC Information.
(meaning)DOT STATION PITCH ERR
(cause)Dot station pitch either X direction or Y direction must be
set "0".
(remedy)Please check the dot station pitch X,Y.