YAMAHA errer code-a.pdf - 第17页
Ea - 17 ERROR MESSAGES LIST Ea Ea00765 Ea00766 Ea00767 Ea00770 Ea00771 Ea00772 Ea00780 Ea00781 Ea00782 Ea00790 Ea00792 Ea00794 Illegal mark number is specified in fiducial data. Have you saved component information? [ESC…

Ea -16
ERROR MESSAGES LIST
Ea
YV88Xabcabcabc
Ea00727
Ea00730
Ea00731
Ea00732
Ea00733
Ea00734
Ea00735
Ea00736
Ea00737
Ea00738
Ea00739
Failed to fix the component in fixed component.
Alternative component error
Failed to read alternative component.
Alternative component error
Loop is not perfect.
Alternative component error
Alternative component specified in the data doesn't ex-
ist.
Machine YV112
Component 3
Alternative component error
"Feeder Type" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"Required Nozzle" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"CountOutStop" is not same as original one.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"UpdateGroupNo" must be all positive or all 0 in loop.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
Mount table is not same as original one.
Alternative component error
You can't use alternative function for tray.
Alternative component error
"Component Name" are different from original one.
(meaning)Components registered in the fixed components cannot
be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Edit the fixed component information and delete the com-
ponent which is causing the interference.
(meaning)An error occurred when reading the alternative compo-
nent data.
(cause)The data for the alternative component specified by the
component data does not exist, or there is a problem with the hard
disk.
(remedy)Go back to the editing screen, and if the alternative com-
ponent does not exist, register it, or change the number of the al-
ternative component.If there is a problem with the hard disk, check
to see how often it occurs, and contact the manufacturer.
(meaning)The settings for alternative components must form a loop
that goes from 1 to 2 to 3 and back to 1 again, but they do not form
this loop.
(cause)The alternative component settings go from 1 to 2 to 3 and
then stop, or form a figure 6 by going from 1 to 2 to 3 and back to 2
again.
(remedy)Go back to the editing screen and check the alternative
component numbers.
(meaning)There is no alternative component data.
(cause)The user has forgotten to register the alternative compo-
nents, or there is a registration error in the alternative component
number.
(remedy)Go back to the editing screen and register the alternative
components, or change the number of the alternative components.
(meaning)The feeder being used for alternative components is not
the same feeder that was used for the original components.
(cause)Same as above.
(remedy)The feeder being used for alternative components must
match the feeder that was used for the original components.
(meaning)The nozzle being used for alternative components is not
the same nozzle that was used for the original components.
(cause)Same as above.
(remedy)Go back to the editing screen and make the nozzle being
used for alternative components match the nozzle that was used
for the original components.
(meaning)The setting for the "count out stop" function used with
alternative components does not match that used with the original
components.
(cause)Same as above.
(remedy)The setting for the "count out stop" function used with al-
ternative components must match that used with the original com-
ponents.
(meaning)In the alternative components loop, all of the settings for
"Use" or "Don't Use" must be set to the same setting.
(cause)In the alternative components loop, some of the compo-
nents reference fixed components, while some do not.
(remedy)Go back to the editing screen and change the settings so
that they all reference fixed components, or none of them do.
(meaning)In the alternative components loop, there are components
with different mounting tables.
(cause)When the settings for the alternative components are 1 -->
2 --> 3, No. 3 is attached to Table B although Nos. 1 and 2 are
attached to Table A, or a different combination of the above.
(remedy)Go back to the editing screen and change the feeder set-
ting numbers so that all of the alternative components are assigned
to the same mounting table.
(meaning)The alternative components cannot be used as tray com-
ponents.
(cause)An attempt was made to use alternative components as
tray components.
(remedy)Go back to the editing screen and change the alternative
component number for the tray components to 0.
(meaning)The name of the alternative component does not match
the name of the original component.
(cause)Same as above.
(remedy)Go back to the editing screen and change the name of
the alternative component so it matches that of the original compo-
nent.
Ea00740
Ea00741
Ea00742
Ea00750
Ea00751
Ea00752
Ea00760
Ea00761
Ea00762
Ea00763
Ea00764
Failed to open fixed component matching work file.
Failed to read fixed component matching work file.
Failed to write fixed component matching work file.
Failed to open fixed component work file.
Failed to read fixed component work file.
Failed to write fixed component work file.
You can't multiply component so many times.
Mount data specifies too big component number.
Selected PCB is not registered in selected line.
Too much point, local and 4-point fiducial data.
Too much mark data.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB dat
a and then delete it. If there is a problem with the disk, check
to see how often the problem occurs, and contact the manufacturer.
(meaning)When component separation is done on the component
information screen, the number of component divisions exceeds
the upper limit.
(cause)An excessively large value was input for the number of com-
ponent divisions
(remedy)Reduce the number of component divisions.
(meaning)The component number specified in the mounting data
exceeds the maximum number of components that the machine
can accommodate.
(cause)The number input for the components in the mounting data
is too large.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(meaning)The selected PCB data has not been registered on the
selected line.
(cause)There is an error in the selection of either the line or the
PCB data, or the PCB data has not been registered.
(remedy)Correct the selection of either the line or the PCB data, or
register the PCB data
(meaning)There are too many elements of point, local or 4-point
fiducial data.
(cause)Too many point, local or 4-point fiducials are being used.
(remedy)Reduce the number of point, local or 4-point fiducials.
(meaning)There are too many elements of mark data.
(cause)There are too many elements of mark data being used for
fiducials and bad marks.
(remedy)Reduce the mark data.

Ea -17
ERROR MESSAGES LIST
Ea
Ea00765
Ea00766
Ea00767
Ea00770
Ea00771
Ea00772
Ea00780
Ea00781
Ea00782
Ea00790
Ea00792
Ea00794
Illegal mark number is specified in fiducial data.
Have you saved component information?
[ESC] key to abort fixed comp. match
Other key to exec fixed comp. match
Have you saved component information?
[ESC] key to abort auto distribution
Other key to exec auto distribution
Failed to open nozzle combination information.
Machine 2
Failed to read nozzle combination information.
Machine 2
Failed to write nozzle combination information.
Machine 2
Failed to read machine configuration.
Machine 2
Failed to read machine data.
Machine 2
Failed to read machine specification.
Machine 2
Now copying PCB data to work data
(DUMMY_GENERATOR).
Generating nozzle file.
Accessing disk.
Wait a few moment.
(meaning)The number of the mark specified in the fiducial data.
(cause)Same as above.
(remedy)Go back to the editing screen and correct the mark num-
ber in the fiducial data.
(meaning)Before fixed component matching is carried out on the
component information screen, the component information must
first be saved. This is a confirmation message asking if the informa-
tion has been saved, and not an error message.
(cause)None
(remedy)If the data has not been saved, press the ESC key. After
the data has been saved, try the fixed component matching. If the
data has already been saved, press any other key to proceed.
(meaning)Before fixed component matching is carried out on the
component information screen, the component information must
first be saved. This is a confirmation message asking if the informa-
tion has been saved, and not an error message.
(cause)None
(remedy)If the data has not been saved, press the ESC key. After
the data has been saved, try the fixed component matching. If the
data has already been saved, press any other key to proceed.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when reading the machine configura-
tion file.
(cause)The software versions do not match, or there is a problem
with the hard disk.
(remedy)Check the software versions, and contact the manufac-
turer.
(meaning)An error occurred when reading the machine data.
(cause)No machine data has been registered; machine data has
been registered which is different from the registered model num-
ber; or there is a problem with the hard disk.
(remedy)Check to see if the machine data has been registered
correctly. If the problem occurs even if the data has been regis-
tered, check to see how often it occurs, and contact the manufac-
turer.
(meaning)An error occurred when reading the machine specifica-
tions.
(cause)The software versions do not match, or there is a problem
with the hard disk.
(remedy)Check the software versions, and contact the manufac-
turer.
(meaning)The PCB data is being copied as work data for creating
data. This is not an error message.
(cause)None
(remedy)Wait for the process to be completed.
(meaning)The nozzle file is being created. This is not an error mes-
sage.
(cause)None
(remedy)Wait for the process to be completed.
(meaning)The disk is being accessed. This is not an error mes-
sage.
(cause)None
(remedy)Wait for the process to be completed.
Ea00796
Ea00797
Ea00801
Ea00802
Ea00802/
BASEa0
Ea00802/
APL=0
Ea00803
Ea00804
Ea00805
Ea00806
Ea00807
Ea00808
Ea00809
Ea00810
Fail to make work data (DUMMY_GENERATOR).
Using the different make data of PCB Information between
the machines.
PCB name and line name were not chosen.
If both of them are not chosen, you can't make data. If
you want to make data, choose again.
QUICK STOP ACTIVE: "NJ06 FRONT-RIGHT COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the front-right cover is cor-
rectly closed.
QUICK STOP ACTIVE: "NJ07 A TABLE, Y AXIS COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the A table, Y Axis cover is
correctly closed.
QUICK STOP ACTIVE: "NJ07 FRONT-FEEDER SEN-
SOR 2"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the front feeders are in-
serted correctly.
QUICK STOP ACTIVE: "NJ07 FRONT-FEEDER SEN-
SOR 2"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the front feeders are in-
serted correctly.
QUICK STOP ACTIVE: "NJ10 FRONT-FEEDER SEN-
SOR"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the feeders are inserted
correctly into the front feeder plate.
If the feeder exchange system is used, also ensure that
the system is fixed properly.
QUICK STOP ACTIVE: "NM06 REAR-RIGHT COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the rear-right cover is cor-
rectly closed.
QUICK STOP ACTIVE: "NM07 B TABLE Y AXIS COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the B table, Y Axis cover is
correctly closed.
QUICK STOP ACTIVE: "NM09 AIR PRESSURE SW",
QUICK STOP FUNCTION for safety is now active. To
continue, please check the supplied air pressure.
QUICK STOP ACTIVE: "NM10 FRONT-FEEDER SEN-
SOR"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the feeders are inserted
correctly into the rear feeder plate.
If the feeder exchange system is used, also ensure that
the system is fixed properly.
QUICK STOP ACTIVE:
"NM13 PCB TRANSFER HOOK LOAD"
QUICK STOP FUNCTION for safety is now active.
Remove the PCB and check the conveyor condition.
QUICK STOP ACTIVE: "NJ11 INTERLOCK ERROR"
QUICK STOP FUNCTION for safety is now active.
Remove the cause of QUICK STOPPING.
QUICK STOP ACTIVE: "NM11 INTERLOCK ERROR"
QUICK STOP FUNCTION for safety is now active.
Remove the cause of QUICK STOPPING.
(meaning)Fail to make the DUMMY_GENERATOR.
(cause)In PCB Inf., difference mark number is used between the
machines.
(remedy)Using the same mark number in PCB Inf. among the ma-
chines.
(meaning)You didn't choose PCB and line name.
(cause)exiting without choice.
(remedy)If you haven't chosen, Choose. If you stop making data, no
need.
(meaning)An emergency stop has occurred because the front cover
of Table A is open, and the interlock has been activated.
(cause)The cover on the front side is open, or the sensor is defec-
tive.
(remedy)Close the cover.
(meaning)The interlock has been activated because the external
axis cover of Table A is open.
(cause)The cover on the front side is open, or the sensor is defec-
tive.
(remedy)Close the cover.
(meaning) Interlock has been activated because outer cover is open
on A table.
(cause) Cover is open or sensor is defective.
(remedy) Close cover.
(meaning) Interlock has been activated because outer cover is open
on A table.
(cause) Cover is open or sensor is defective.
(remedy) Close cover.
(meaning) Sensor that detects front-side feeders which are not firmly
seated has detected loose feeder.
(cause) Feeder has not been installed correctly, or sensor is defec-
tive. In some cases, this message is displayed during an emergency
stop, but this is normal and does not indicate a problem.
(remedy) In any case other than an emergency stop, check feeder
installation.
(meaning)The rear cover of Table B is open.
(cause)A cover is open, or the sensor is defective.
(remedy)Close the cover.
(meaning)The interlock has been activated because the front axis
cover of Table B is open.
(cause)A cover is open, or the sensor is defective.
(remedy)Close the cover.
(meaning) Sensor that detects rear-side feeders which are not firmly
seated has detected loose feeder.
(cause) Feeder has not been installed correctly, or sensor is defec-
tive. In some cases, this message is displayed during an emergency
stop, but this is normal and does not indicate a problem.
(remedy) In any case other than an emergency stop, check feeder
installation.
(meaning)The load on the PCB transport unit is excessive, and the
interlock has been activated.
(cause) The edge of a PCB has gotten caught on the edge of the
connecting section of the conveyor, or an excessive load is placed
on the transport unit because the PCB is too wide for the conveyor,
thus activating the interlock.
(remedy)Find out where the excessive load is occurring, and adjust
the PCB width or the conveyor position.
(meaning) The interlock of the quick-stop function connected to NJ11
has been detected, and the emergency stop function has been ac-
tivated.
(cause) This depends on optional equipment being used.
(remedy) This depends on optional equipment being used.
(meaning) The interlock of the quick-stop function connected to
NM11 has been detected, and the emergency stop function has
been activated.
(cause) This depends on optional equipment being used.
(remedy) This depends on optional equipment being used.

Ea -18
ERROR MESSAGES LIST
Ea
YV88Xabcabcabc
Ea00811
Ea00812
Ea00850
Ea00851
Ea00852
Ea00853
Ea00854
Ea00855
Ea00856
Ea00857
Ea00858
Ea00859
Ea00860
QUICK STOP ACTIVE:
"NJ08 FRONT-FEEDER PLATE SENSOR"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the front feeder plate is in-
serted correctly.
QUICK STOP ACTIVE:
"NM08 FRONT-FEEDER PLATE SENSOR"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the front feeder plate is in-
serted correctly.
INTERLOCK ERROR
Head lower sensor is OFF. Remove the cause of this
sensor OFF.
INTERLOCK ERROR
Transfer axis up/down sensor is OFF. Remove the cause
of this sensor OFF.
INTERLOCK ERROR
The sensor of main stopper or pushup or entrance stop-
per is ON. Remove the cause of this sensor ON.
INTERLOCK ERROR
Z-position of head No.1 is in dangerous zone. Please
change Z-position by your hand after pressing EMG but-
ton.
INTERLOCK ERROR
Z-position of head No.2 is in dangerous zone. Please
change Z-position by your hand after pressing EMG but-
ton.
INTERLOCK ERROR
The lower sensor of head No.1 is OFF. Remove the cause
of this sensor OFF.
INTERLOCK ERROR
The lower sensor of head No.2 is OFF. Remove the cause
of this sensor OFF.
INTERLOCK ERROR
Z-position of head No.1 is not suitable for LED backlight
moving. Please change LED backlight position to the right
side.
INTERLOCK ERROR
Z-position of head No.2 is not suitable for LED backlight
moving. Please change LED backlight position to the right
side.
INTERLOCK ERROR
LED backlight should be right. Please change LED back-
light position to the right side.
INTERLOCK ERROR
External Tray Changer head is down now. Please change
the output to go up in manual.
(meaning)The feeder plate seating sensor for the bulk setup feeder
plate has detected a feeder which is not securely seated, and the
interlock has been activated.
(cause)The feeder plate has not been attached securely, or the
sensor is malfunctioning.
(remedy)Make sure the feeder plate is attached securely.
(meaning)The feeder plate seating sensor for the bulk setup feeder
plate has detected a feeder which is not securely seated, and the
interlock has been activated.
(cause)The feeder plate has not been attached securely, or the
sensor is malfunctioning.
(remedy)Make sure the feeder plate is attached securely.
(meaning)The head descent end sensor is off.
(cause)The head does not ascend because of an operational mal-
function or a sensor error.
(remedy)Check the vertical movement of the head.
(meaning)The descent end sensor on the PCB transport unit is off.
(cause)The PCB transport unit has remained in its lowered posi-
tion, or the sensor is malfunctioning.
(remedy)Check the vertical movement of the PCB transport unit.
(meaning)At the point when an attempt was made to transport
PCBs, the sensor for the main stopper, the pushup, or the entrance
stopper went on, and one of these has ascended.
(cause)The sensor is malfunctioning, or the actuator is defective.
(remedy)Check the action of the main stopper, the pushup, and
the entrance stopper.
(meaning)The height of the Z axis on Head 1 is not appropriate for
the movement of the head.
(cause)An attempt was made to begin operation under inappropri-
ate conditions.
(remedy)Press the Emergency Stop button and pull the head up-
wards. Then start operation again.
(meaning)The height of the Z axis on Head 2 is not appropriate for
the movement of the head.
(cause)An attempt was made to begin operation under inappropri-
ate conditions.
(remedy)Press the Emergency Stop button and pull the head up-
wards. Then start operation again.
(meaning)The descent end sensor of Head 1 is on.
(cause)The head has not ascended, or the sensor is malfunction-
ing.
(remedy)Press the Emergency Stop button and raise the head.
(meaning)The descent end sensor of Head 2 is on.
(cause)The head has not ascended, or the sensor is malfunction-
ing.
(remedy)Press the Emergency Stop button and raise the head.
(meaning)The relation between the position of the Z axis of Head 1
and the LED illumination for backlighting is not appropriate for move-
ment.
(cause)An attempt was made to begin operation under inappropri-
ate conditions.
(remedy)Press the Emergency Stop button, remove the nozzle,
and pull the head upwards. Then move the backlighting to the right
and start operation again.
(meaning)The relation between the position of the Z axis of Head 2
and the LED illumination for backlighting is not appropriate for move-
ment.
(cause)An attempt was made to begin operation under inappropri-
ate conditions.
(remedy)Press the Emergency Stop button, remove the nozzle,
and pull the head upwards. Then move the backlighting to the right
and start operation again.
(meaning)The position of the LED for backlighting illumination is
not appropriate for movement.
(cause)An attempt was made to begin operation under inappropri-
ate conditions.
(remedy)Press the Emergency Stop button, remove the nozzle,
and pull the head upwards. Then move the backlighting to the right
and start operation again.
(meaning)The head of the external tray changer is in the lowered
position.
(cause)The head of the external tray changer has descended, or
the sensor is detecting the lowered position.
(remedy)Switch the manual mode, raise the pickup head for the
external tray, and start operation again.
Ea00861
Ea00862
Ea00863
Ea00901
Ea00902
Ea00903
Ea00904
Ea00905
Ea00906
Ea00907
Ea00908
Ea00909
Ea00910
INTERLOCK ERROR
Some pallet of tray unit is out from the rack. Please set it
into the rack.
INTERLOCK ERROR
A pallet is on the table.
Store it in the magazine.
INTERLOCK ERROR
Pallet latch condition is illegal. Please check latch sen-
sor.
DEFINED MAXIMUM AMOUNT OF PCBs
FOR THE UNLOADER IS REACHED:
Waiting for the reset-signal from the unloader, or.
Execute EDIT PRD.HISTORY/INITIALIZE PCB
COUNTER in 1/1/D4 RUNNING UTILITY to restart with
new rack.
Set the parameter [Pcb/Unloader], in the [PCB informa-
tion] menu to 0 to ignore this.
DEFINED PRODUCTION AMOUNT OF PCBs IS
REACHED.
To continue the production, set the [Pcb/Schedule] pa-
rameter to 0. When switching the PCB data, make sure
that there is no PCB on the buffer conveyor.
Ready to start WARMING UP.
REMOVE:
■ Any board on the conveyor
■ All Push-up pins.
■ other obstructing items.
Push the [ESC] key to abort WARMING UP and to return
to the command menu.
Now WARMING UP .....
Press the [ENTER] key to stop WARMING UP.
Stopped according to CONVEY OUT PCB command.
When switching the PCB data, make sure that there is
no PCB on the buffer conveyor.
EMERGENCY STOP function is now active. Select power
off sequence
[READY] :power off sequence is active.
[ENTER] : power off sequence is in-active.
Be careful for Safety !!! Machine axes will move.
[ENTER] : execute
[Others] : abort
Machine is changing the back light position
to the right now! Please wait...
Failed to search origin
by EMERGENCY SWITCH or SERVO ERROR.
ILLEGAL TRAY DATA DURING RUNNING-1
Meaning: Illegal data during running.
Recovering: Pls. RESET RUNNING.
(meaning)The pallet of the external tray changer is protruding from
the magazine.
(cause)The pallet eject sensor in the magazine has been activated.
(remedy)Store the pallet in a position in the magazine where it does
not activate the pallet eject sensor.
(meaning)The status of the operation sensor in the latching section
where pallets are stored in the tray changer is inappropriate for
movement.
(cause)The operation of the latch sensor is inappropriate.
(remedy)Re-adjust the latch sensor, or push the pallet to a position
where the sensor operates correctly.
(meaning) Waiting for reset signal from unloader side, because
specified number of PCBs have been unloaded to subsequent pro-
cess.(cause) Number of PCBs has been reached which signifies
that unloader is full, and unloading of PCBs has stopped because
number/capacity of PCBs in unloader has reached number set in
PCB information.
(remedy) Replace unloader rack, or, if control is incorrect, set num-
ber/capacity of unloader PCBs to 0.
(meaning) Production has been stopped because the specified num-
ber of PCBs have been produced.
(cause) The number of PCBs to be produced has been specified in
the PCB information and that number has been reached.
(remedy)Shift to the PCB information, and on the PCB information
screen, specify the additional number of PCBs to be produced. Then
start the operation again.
(meaning)This is a notice that warmup operation is beginning.
(cause)The warmup instruction has been issued.
(remedy)Nothing needs to be done. This is not an error.
(meaning)This indicates that warmup is in progress.
(cause)None
(remedy)None
(meaning)After components have been mounted on the PCB and
the eject command has been used, the equipment stopped.
(cause)The components have been mounted on the PCB and the
eject command was issued. Mounting of all PCBs being loaded at
that point is brought to a stop.
(remedy) To continue production, press the Run key at this point.
Operation will be restarted.
(meaning) When operation is concluded, an emergency stop is in
progress, and there are several steps that have to be taken in order
to turn the power supply off.
(cause)An emergency stop is in progress.
(remedy)Press the Ready button to cancel the emergency stop sta-
tus.
(meaning)This is a warning message alerting the user that the axis
is going to move in order to end the processing. It is not an error.
(cause)None
(remedy)Press the Enter key to conclude the processing.
(meaning)This notifies the user that the backlighting illumination is
being moved to the right.
(cause)None
(remedy)Wait until the message disappears from the screen.
(meaning)An error occurred in the servo system hardware when a
return to the origin point was carried out.
(cause)The Emergency Stop button was pressed during a return to
the origin point, or the servo is defective.
(remedy)Do not use the Emergency Stop button while a return to
the origin point is in progress. Check how often the problem occurs,
and contact the manufacturer.
(meaning)A problem occurred with tray changer control during op-
eration.
(cause)Because the operation is complex, the system has lost track
of where the component is.
(remedy)Reset the system.