Ea - 20 ERROR MESSAGES LIST Ea Ea01019 Ea01020 Ea01021 Ea01022 Ea01023 Ea01024 Ea01025 Ea01026 Ea01027 Ea01028 Ea01029 Ea01030 Ea01031 Ea01032 OPTION ERROR This option is not implemented in this software. This func- tion…

Ea -19
ERROR MESSAGES LIST
Ea
Ea00911
Ea00920
Ea00921
Ea00922
Ea00925
Ea00926
Ea00950
Ea00951
Ea00952
Ea00953
Ea00954
Ea00955
Ea00956
ILLEGAL TRAY DATA DURING RUNNING-2
Meaning: Illegal data during running.
Recovering: Pls. RESET RUNNING.
COMP.GLOBAL TO TEXT had been completed.
To use EXPERT SETUP, start EXPERT SETUP right now.
SET FROM/TO DATABASE has been completed.
SET TO STATIC_COMPONENT___ has been completed.
Please use this command in Component Info.
Please read the help message carefully before execut-
ing this command.Ready to execute database matching?
Press the [SPACE] key to execute, or any other key to
abort.
CO-PLANARITY CHECK ERROR
Head down position sensor error. Please check the me-
chanical position of Co-Planarity sensor and sensor
sensivity.
CO-PLANARITY CHECK ERROR
Horizontal scanning safety check sensor of Co-Planarity
checked danger. Bad position of Co-Planarity sensor, or
picking error is too big. his component. Or size of com-
ponent is no good. Please check these items.
CO-PLANARITY CHECK ERROR
Error of position of Co-Planarity Check sensor. Please
check the mechanical position of Co-Planarity Check
sensor.
CO-PLANARITY CHECK ERROR
This component is out of regulation. of Co-Planarity Check
sensor. Only "QFP","SOP"is suitable. Or 20.5mm square
is minimum size and 45mm square is maximum size for
Co-Planarity check.
CO-PLANARITY CHECK ERROR
Picking position is bad for Co-Planarity Check. Picking
error is too large for Co-Planarity. Please check the pick-
ing position.
CO-PLANARITY CHECK ERROR
Co-linearity check found the lead out of tolerance.
CO-PLANARITY CHECK ERROR
Vacuum check error.
(meaning)A problem occurred with tray changer control during op-
eration.
(cause)Because the operation is complex, the system has lost track
of where the component is.
(remedy)Reset the system.
(Meaning)This message appears when the [COMP. GROVAL TO
TEXT] command had been completed using YVOS2 with option
EXPERT SW.
(Cause)[COMP. GROVAL TO TEXT] command had been com-
pleted.(Remedy)To execute expert SW, click the icon of expert SW,
or just press [enter] key for another operation.
(Meaning)Succeeded in [SET FROM DATABASE] or reserse set
into the database.
(Cause)[SET FROM DATABASE] or reserse set into the database
had been done.
(Remedy)Press [Enter].
(Meaning)The component data had been registered into the
STATIC_COMPONENT.
(Cause)The command to register the data into STATIC COMPO-
NENT had been executed.
(Remedy)Press [Enter].
(Meaning)A command only for component information is used for
another data.
(Cause)The MAIN WINDOW is not component info.
(Remedy)Press[F3] to change window into component info.
(Meaning)This is the warning message before executing database-
matching.
(Cause)DATABASE MATCHING had been commanded.
(Remedy)Press [SPACE] to execute or other key to cancel.
(meaning)A lead which is not securely attached has been detected,
but the sensor which causes the head to descend has not reacted.
(cause)The sensor has malfunctioned, or there is a problem with
the position coordinates of thedevice which detects leads which
are not securely attached.
(remedy) Trace the position coordinates using the machine data
editing function, and check the operation of the sensor.
(meaning)When an attempt was made to detect loose leads, the
safety check sensor on the device which detects leads which are
not securely attached alerted the user of danger.
(cause)The sensor may have reacted to the sensor which prevents
contact between the nozzles and components and the loose lead
detection (co-planarity) unit.
(remedy)Check the relative heights of the units, and if the sensor
needs to be adjusted, adjust it. Otherwise, if the pickup tolerance
for the components is excessive, adjust the pickup position.
(meaning)There is a problem with the position data for the loose
lead detection (co-planarity) unit.
(cause)The data has not been adjusted properly.
(remedy)Re-adjust the data.
(meaning)An attempt was made to detect loose leads on a compo-
nent which is not within the specifications of the loose lead detec-
tion (co-planarity) unit.
(cause)Detection of loose leads is specified in the data for compo-
nents whose specifications do not allow this type of detection.
(remedy)If there is an error in the component size or other data,
change the input value. Otherwise do not specify that the loose
lead detection (co-planarity) function be used.
(meaning)Because the pickup tolerance is excessive, the loose lead
detection (co-planarity) unit cannot be used.
(cause)The pickup tolerance is excessive.
(remedy)Raise the level of the pickup precision, or stabilize the
pickup conditions.
(meaning)A lead has been detected which is not within the range
set for results of loose lead detection (co-planarity).
(cause)The lead on the component is not securely attached.
(remedy)Do not use that component, or, if the value set for loose
lead detection (co-planarity) is too strict, change it to a more le-
nient setting.
(meaning)During detection of loose leads, the pickup sensor which
checks for the presence of components detects that there are no
more components.
(cause) The component may have fallen off during lead detection,
or the pickup and mounting level has not been set properly.
(remedy)Check to see if the component is still on the nozzle, and
check the setting of the pickup and mounting level.
Ea00957
Ea00958
Ea00959
Ea00970
Ea00999
Ea01000
Ea01001
Ea01002
Ea01003
Ea01004
Ea01010
Ea01018
CO-PLANARITY CHECK ERROR
CO-PLANARITY CHECK ERRORdition Error.
Please once reset and run. Co-Planarity Check sensor
and board Condition Error. Please once reset and run.
In case machine does not recover by this way, please
check the indicator of Lase Lead Locator board. If it is
flashing in red, once power off and power on again.
CO-PLANARITY CHECK ERROR
Co-Planarity Check sensor cannot get good result. Please
check the mechanical position. of Co-Planarity Check
sensor.
CO-PLANARITY CHECK ERROR
Co-Planarity Check sensor data error.", "SOP". In case
for using Co-Planarity Check these conditions are need,
1. Vision type is suitable only "QFP","SOP".
2. There is option of Co-Planarity.
3. Component size is within reguration.
PCB FILE READ ERROR
The amount of data exceeds the limit, 2560p(points).
The counting of each lines are as follows.
Mount Data'(1p),
Block Repeat'(2p),
Fiducial Inf'(3p),
PreDispense'(1p),
DotDispense'(1p).
Reduce the number of data.
RETRY active.
PCB name : [CUK93001]
CAUTION: PCB data is new or changed and requires a
backup.
Insert a backup DISKETTE in the FLOPPY DRIVE, se-
lect "START MAINTENANCE" and press the [ENTER]
key, or.. Press the [ESC] key to skip the backup.
PCB name : [CUK93001]
Writing backup data now.
Please wait a moment....
PCB name : [CUK93001]
FLOPPY DISK DRIVE is not ready.
Data cannot be backed up.
PCB name : [CUK93001]
DISK is not prepared for VIOS.
Data cannot be backed up.
PCB name : [CUK93001]
Cannot execute data backup. The reason is as follows.
■ Floppy disk is full.
■ Floppy disk has bad sector.
PCB name : [CUK93001]
Now reading data.
Please wait a moment....
/0000/1000/E
OPTION ERROR
This option is not implemented in this software. This func-
tion is available only in the surface-mounter.
(meaning)Communication with the loose lead detection (co-planar-
ity) unit is not
(cause)There is a problem with the communications cable connect-
ing the loose lead detection (co-planarity) unit, or the unit itself is
defective
(remedy)Contact the manufacturer.
(meaning)An error occurred in detecting loose leads (checking co-
planarity).
(cause)The component lead does not pass through the area it must
be in in order for loose leads tobe detected.
(remedy)Re-adjust the height data and the X and Y position data
for the loose lead detection (co-planarity) unit, which are found
among the component thickness or the mechanical coordinates.
(meaning)The conditions necessary for executing loose lead de-
tection (co-planarity) have not been met.
(cause)The data has not been specified correctly.
(remedy)Check to see whether the recognition type is set to QFP or
SOP, and that the loose lead detection (co-planarity) unit has been
installed. If the above conditions cannot be met do not use the loose
lead detection (co-planarity) unit.
(meaning) File being read exceeds specified file length.
(cause) Using CAD conversion or other means, data was created
which exceeds specified file length.
(remedy) Delete data which exceeds file length.
(meaning)This is not an error message.
(cause)None
(remedy)None
(meaning)This is a warning that PCB data exists which has been
edited, but the revised version has not been backed up.
(cause)There is PCB data for which changes have been entered,
but the revised data has not been backed up.
(remedy)Insert the PCB data disk in the floppy disk drive and press
the Enter key. To proceed without backing up the data, simply press
the ESC key.
(meaning)This message indicates that data is being backed up. It
is not an error message.
(cause)None
(remedy)Wait until the process has been completed.
(meaning)An attempt was made to back up data, but no floppy disk
which can read the data has been inserted in the drive.
(cause)The backup process was started without inserting the floppy
disk.
(remedy)Insert the floppy disk and then press the Enter key once
more. If no floppy disk is available, press the ESC key.
(meaning)An attempt was made to back up data, but the floppy disk
has not yet been made the PCB data disk.
(cause)A floppy disk is being used for which the PCB data disk
creation command has not been used to make it a PCB data disk.
(remedy)Use a floppy disk which has been made into the PCB data
disk using the PCB data disk creation command. To cancel the
backup process, press the ESC key.
(meaning)An error occurred when backing up data.
(cause)The floppy disk is full; there is a faulty sector on the disk; or
the floppy disk was ejected before the backup process was com-
pleted.
(remedy)Insert a different PCB data disk and execute the command
again.
(meaning)An attempt was made to use optional equipment which
has not been installed, or an option is being used which can be
used only with the mounter itself.
(cause)Same as above.
(remedy)None

Ea -20
ERROR MESSAGES LIST
Ea
Ea01019
Ea01020
Ea01021
Ea01022
Ea01023
Ea01024
Ea01025
Ea01026
Ea01027
Ea01028
Ea01029
Ea01030
Ea01031
Ea01032
OPTION ERROR
This option is not implemented in this software. This func-
tion is not available.
COMMAND ERROR
You cannot select this item, because the PROTECT LI-
CENSE is not given.
RUNNING PCB NOT SELECTED
Because "PRODUCTION PCB" had not indicated in the
<<RUNNING>> mode, you cannot select this mode at
this moment.
OPTION ERROR
This option is not implemented in this software. This func-
tion is for an other type of machine.
WARNING: NOT ENOUGH HDD SPACE
Free space on Hard Disk is less than 10MB. To avoid the
possibility that you cannot save new data anymore and
that data might get lost, it is best to create, now, new
space on the hard disk. Copy unused PCB data to floppy,
and delete from the hard disk.
ERROR:NOT A MOUNT DATA.
This function is available only if OBJECT is MOUNT.
Please select MOUNT in [A1 MAIN WINDOW] at first.
HardWare-key is not ready.
Put HardWare-key to the printer port, and boot again.
You can't add any more PCB data.
Copy PCB data to floppy disk, and reduce the number of
PCB data in HDD.
Only the machine data of the surface mounter and the
dispenser can be edited in this mode.
This machine is not UFOS type.
Copy into the data area for UFOS machine to convert.
On PC,
UFOS(FD)<->VIOS CONVERT
VIOS->PRINT FORMAT(PRT\)
is not able for a data on floppy. Copy into the data area
for UFOS machine in PC.
Not enough memory to execute.
The data [STATIC_COMPONENTS] is component data
common for all PCB DATA in a machine.
Only COMPONENT INFORMATION is available for the
data [STATIC_COMPONENTS].
(meaning)An attempt was made to use optional equipment which
has not been installed, or an option is being used which can be
used only with the mounter itself.
(cause)Same as above.
(remedy)None
(meaning)An item has been selected which cannot be used be-
cause the protective license has not been input.
(cause)The protective license has not been input.
(remedy)Input the protective license and run the process again.
(meaning)The selected command cannot be executed because the
PCB to be produced in the automatic operation mode has not been
decided.
(cause)The PCB to be produced in the automatic operation mode
has not been decided.
(remedy)Specify the PCB to be produced in the automatic opera-
tion mode and then execute the command again.
(meaning)An attempt was made to use optional equipment designed
for a different model.
(cause)Same as above.
(remedy)None
(meaning)This alerts the user to danger arising from the remaining
capacity of the hard disk dropping to less than 10 megabytes.
(cause)There is too much data.
(remedy)Back up any unnecessary PCB data and delete it from
the hard disk.
(meaning)A function which can only be used with the placing infor-
mation has been selected although the placing information is not
shown on the editing screen.
(cause)The placing information is not shown on the editing screen.
(remedy)Change the editing screen to show the placing informa-
tion.
(meaning) The hard keys provided by the manufacturer have not
been connected to the personal computer for which the offline soft-
ware is designed.
(cause)The computer does not have the proper hard keys, or the
hard keys have not been correctly installed in the printer terminal.
(remedy)Install the hard keys correctly in the printer terminal.
(meaning)No more PCB data can be registered.
(cause)There is not enough space left on the hard disk, or the num-
ber of PCB data registered exceeds the allowable limit.
(remedy)Back up any unnecessary PCB data and delete it from
the hard disk.
(meaning)Only the machine data of the surface mounter and the
dispenser can be edited.
(cause)Same as above.
(remedy)None
(meaning)An attempt was made to carry out UFOS/ VIOS conver-
sion on a VIOS machine.
(cause)Same as above.
(remedy)Switch the screen to a registered UFOS machine and use
that screen for the UFOS/VIOS conversion.
(meaning)With the YVOS, floppy disks cannot be used to generate
data for UFOS/VIOS data conversion and VIOS printing data con-
version.
(cause)The data to be converted is contained on a floppy disk and
not on the hard disk.
(remedy)Copy the data to be converted from the floppy disk to the
hard disk and then run the conversion function again.
(meaning)Not enough memory can be assured to run the program.
(cause)There is a problem with the board or another element.
(remedy)Check to see how often the problem occurs, and contact
the manufacturer.
(meaning)The data called STATIC-COMPONENTS is called fixed
component information and is component information which is com-
mon to all PCBs. This data is used with components which are not
removed when setups are changed on the feeder plate or tray
changer. This is not an error message.
(cause)None
(remedy)None
(meaning) STATIC-COMPONENTS is fixed component data and
cannot be edited apart from component information.
(cause)None
(remedy)None
Ea01033
Ea01034
Ea01035
Ea01037
Ea01040
Ea01041
Ea01045
/BASE `
Ea01045
/APL=4
Ea01046
Ea01200
Ea01202
Ea01203
Ea01204
COMMAND ERROR
This command is not (yet) available.
Please wait a moment
while changing modes...
MOVING AREA OVER
The target position is outside the moving area.
Axes X1
Are you sure?
[ESC] : No
Others: Yes
It isn't able to display templet on this window.
You can display templet on mark-information window.
It's not reserved extent of copy or delete.
YVOS2 stops copying or deleting.
<<Daily Examination>> <<Check>> <<Predicted Error>>
>NOZZLE TIP Break, Solder Pick-up, Recognition
Spring func . Pick-up, Comp. damage
>LEAF SPRING Spring func. Placement, Nozzle
change
>NOZZLE HOLDER Spring func. Pick-up, Comp. dam
age
>LASER WINDOW Cleaning Recognition
>CAMERA LENS Cleaning Recognition
>FEEDER Shutter Feeding, Pick-up
>FEEDER PLATE Cleaning Placement, Pick-up
Please refer to the manuals in detail.
<<Daily Examination for Dispenser>>
<<Item>>:<<Check point>>:<<Problems to be pre-
vented>>
<Nozzle hole>:
Stuffed with glue :Unstable dot
<Dispensing Pump>
Shortage of cleaning :Unstable dot
<Dispensing Glue>
Old or quality changed :Unstable dot
Please refer to chap. 4 of [User's Manual] in detail.
YEAR 2000 DETECTED
Thank you to use our surface mounter and dispenser.
At the 1st power on after 1 Jan 2000, please set the date
value again.
To correct the date value again, the command 4/2/D4 is
also available.
Failed to create VIOS PCB file. This can be cause by the
following:
■ Total number of PCB data exceeds 127
■ PCB name already exists.
■ Not enough space to create PCB on Hard Disk.
Failed to copy VIOS PCB file.
Failed to remove VIOS PCB file.
WARNING:VIOS FLOPPY IN THE DRIVE IS NOT FAM-
ILY
The floppy in the drive seems to be VIOS type.
The floppy in the drive has unknown machine data.
The floppy in the drive is not made by this machine.
Press [ENTER]key to select machine and open floppy
drive, or any other key to abort.
(meaning)The specified command cannot be used.
(cause)An attempt was made to use a command which cannot be
used.
(remedy)None
(meaning)The mode is being switched. This is not an error mes-
sage.
(cause)None
(remedy)Wait until the process has been completed.
(meaning)The target positions of the displayed axes are outside
the moving area.
(cause)Same as above.
(remedy)Modify target positions.
(meaning)Confirmation of user operation.
(cause)None
(remedy)None
(meaning)Cannot display templet.
(cause)This window is not mark-information.
(remedy)Move to mark-information window.
(meaning)YVOS stops copying or deleting.
(cause)It's not reserved extent.
(remedy)After reserving extent, copy or del.
(Meaning)This message is to show daily required maintenance items
just after power up of the machine.
(Cause)Starting up of the machine.
(Remedy)Read message and press [Enter].
Or press [Enter] during the starting up to skip this message.
(Meaning)This message is to show daily required maintenance items
just after power up of the machine.
(Cause)Starting up of the machine.
(Remedy)Read message and press [Enter].
Or press [Enter] during the starting up to skip this message.
(Meaning)Reporting the date and time data should be done again,
and requiring to set correct data.
(Cause)Starting up of the machine just after year 2000 comes.
(Remedy)ÅzSet date and time.
(meaning)An error occurred in registering VIOS PCB data.
(cause)An attempt was made to create data which exceeds the
maximum limit of 127 PCBs; an attempt was made to register new
data under an already existing PCB name; there is not enough space
left on the hard disk; or there is not enough space left on the floppy
disk.
(remedy)If the maximum limit of 127 PCBs has been exceeded,
copy some of the data to a floppy disk and then delete it from the
hard disk. If you are trying to create new data under an already
existing PCB name, register the data again under a different name.
(meaning)An error occurred when copying a VIOS PCB file.
(cause)There is not enough space on the destination disk; the num-
ber of data registered on the destination disk has already reached
127; or there is a problem with the disk containing the original data.
(remedy)Reduce the amount of data registered on the destination
disk, and check the original disk and the data for problems.
(meaning) An error occurred when deleting a PCB file.
(cause) There is a problem with the drive or the disk.
(remedy) Cancel the write protect function on the floppy disk.
(meaning) An attempt was made to use floppy disk created using a
machine not registered in YVOS2.
(cause) An attempt was made to use YVOS2 to process floppy disk
from machine which has not been registered.
(remedy) Create PCB data disk in PCB data management mode, and
change attributes of that floppy disk to those of machine registered in
YVOS2. Or, press [ENTER] key and forcibly select target machine.

Ea -21
ERROR MESSAGES LIST
Ea
Ea01205
Ea01206
Ea01207
Ea01208
/B
Ea01208
/A
Ea01209
Ea01210
Ea01211
Ea01212
WARNING:UFOS FLOPPY IN THE DRIVE IS NOT FAM-
ILY
The floppy in the drive seems to be UFOS type. The floppy
in the drive has unknown machine data. The floppy in
the drive is not a one made by this machine.
ERROR: This command is available during vios-mode.
Illegal machine selection:
Undefined machine can not be selected in VIOS mode.
A machine not UFOS can not be selected in UFOS mode.
Ready to remake SYSTEM DATA BACKUP DISK.
Please insert
SYSTEM DATA BACKUP DISK for MOUNTER
and hit [ENTER].
Ready to remake SYSTEM DATA BACKUP DISK.
Please insert
SYSTEM DATA BACKUP DISK for YVOS
and hit [ENTER].
Failed to complete to update SYSTEM DATA BACKUP
DISK.
You can not switch machine. The machine is decided by
PCB data disk in the floppy drive. To switch machine,
take out the PCB data disk from the floppy drive and se-
lect
[ A1 SEARCH DRIVE ] first.
ASCII DATA Pick Up error.
ERROR CODE1 : 2
Detail :1:Comp.Info.
2:Mark Info.
3:PCB Info.
0:Others. Refer to ERROR CODE2.
ERROR CODE2 : 5
Detail : 0:LocalBadMrk Info.
1:Pre Disp. Info.
2:Dot Disp. Info.
5:Local Fidu.Info.
6:Mount Info.
7:PCB Origin
8:Blk Repeat Info.
9:PCB Size
10:PCB Fiducial
11:BLOCK Fiducial
12:PCB Badmark
13:BLOCK Badmark
ASCII->VIOS Conversion error.
ERROR CODE1 : 3
Detail : 1:Comp.Info.
2:Mark Info.
3:PCB Info.
0:Others. Refer to ERROR CODE2.
ERROR CODE2 : 10
Detail : 0:LocalBadMrk Info.
1:Pre Disp. Info.
2:Dot Disp. Info.
5:Local Fidu.Info.
6:Mount Info.
7:PCB Origin
8:Blk Repeat Info.
9:PCB Size
10:PCB Fiducial
11:BLOCK Fiducial
12:PCB Badmark
13:BLOCK Badmark
(meaning) A UFOS floppy which has not been registered on the
YVOS2 has been detected in the floppy disk drive.
(cause)Same as above.
(remedy)In the PCB data control mode, shift to the UFOS data
directory and then create the PCB data disk.
(meaning)A command which can only be used in the VIOS mode
was used in the UFOS mode.
(cause)The screen does not match the operation.
(remedy) Eject the floppy disk from the drive and select the VIOS
mode. Then execute the command in the VIOS mode.
(meaning)The wrong machine number was selected
(cause) An attempt was made to select a VIOS machine in the
UFOS mode, or an attempt was made to use a machine which has
not been registered as a VIOS or UFOS machine.
(remedy) When selecting a UFOS machine, first eject the floppy
disk from the drive and shift to the UFOS mode. Then select the
machine.
(meaning)This notifies the user to insert the data disk contained on
the installation disk in the disk drive in order to back up system
data.
(cause) None
(remedy) Insert the specified floppy disk in the disk drive.
(meaning)System data could not be backed up.
(cause)There may be a problem with the disk.
(remedy)Contact the manufacturer for instructions.
(meaning)It cannot switch machine.
(cause)The machine decided by PCB disk in the floppy drive.
(remedy)Take out the PCB data disk from the floppy drive and se-
lect [ A1 SEARCH DRIVE ] first.
(meaning)It cannot find out the convert lines.
(cause)There is nothing inside the CAD data that inputed string of
search item.
(remedy)Look "Serch" over again.
(meaning)It cannot convert the data from CAD to VIOS.
(cause)There is no character inside the CAD data.
(remedy)Look "Data get" over again.
Ea01221
Ea01222
Ea01223
Ea01230
Ea01231
Ea01232
Ea01233
Ea01234
Ea01235
Ea01236
ASCII data analyzing error. The following error occurs.
1:Comp.Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
2:Mark Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
3:PCB Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
0:LocalBadMrk Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
1:Pre Disp.Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
2:Dot Disp.Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
3:Unknown
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
4:Unknown
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
5:Local Fidu.Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
ASCII data analyzing error. The following error occurs.
6:Mount Info.
If the detected string do not have any characters, this
error happens.
If any data do not fit with search keyword, also this error
happens.
(Meaning)During ASCII’VIOS conversion, a string picked up follow-
ing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.
(Meaning)During ASCII→VIOS conversion, a string picked up fol-
lowing to the conversion font, is completely SPACE and do not con-
tains any other character. Or no data line suit to the search condi-
tions indicated in the conversion font.
(Cause)qIllegal source file for the conversion.wConversion font is
not for the source file.
(Remedy)qCorrect source file, or conversion font file.