YAMAHA errer code-a.pdf - 第5页

Ea - 5 ERROR MESSAGES LIST Ea Ea00126 Ea00127 Ea00130 Ea00131 Ea00132 Ea00133 Ea00134 Ea00135 Ea00136 Ea00137 Ea00138 Ea00139 Ea00140 Ea00141 Ea00142 Ea00143 Initializing PCB counter . Please wait a moment.... Changing P…

100%1 / 42
Ea -4
ERROR MESSAGES LIST
Ea
Ea00091
Ea00092
Ea00093
Ea00094
Ea00095
Ea00100
Ea00101
Ea00102
Ea00103
CO-PLANARITY CHECK LEAD DETECT ERROR
A reflective object was detected at the start position of
scanning. Please check Body Size in Component Info.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD DETECT ERROR
Failed to detect the end of edge on the last lead.
Please check Body Size in Component Info.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD NUMBER ERROR
Failed to detect the specified number of leads.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD GAP ERROR
The gap between the adjacent leads is out of the thresh-
old.
Mount data
Component data
Feeder set position
CO-PLANARITY CHECK LEAD CO-PLANARUTY ER-
ROR
Co-planarity level is out of the threshold.
Mount data
Component data
Feeder set position
EMERGENCY STOPPING FUNCTION
for safety is now active. Confirm Safety and push the
SERVO ON SWITCH to enable the machine. If you suc-
ceed, the RED-MESSAGE-LIGHT will be switched off.
Please make sure that the EMERGENCY STOP is ON.
When you wish to turn off the power, you have to make
sure that the EMERGENCY STOP is ON.
SEARCH FOR ORIGIN is not performed yet. Select
SEARCH ORIGIN first by using the COMMAND LISTS.
Ready to turn off Power.
A) System can be switched off now, or
B) Push any key to enter SLEEP mode.
Unsaved data in memory will be lost when the system is
switched off without this message being displayed.
(Meaning)Co-planarity checking function inspect a component along
to the rectangle shape which include the component size as its
inside, and it should not detect leads at the corner position of that
rectangle. Because co-planarity checking start and finish scanning
always at the corner position of that rectangle, if a lead is detected
at the start position or finish position, this error message appears
to inform the problem.
(Cause)qThe size definition of the component is wrong.wSome ob-
stacle so as bumper is at the corner position and had been
detected.eBecause some shape information so as number of leads
is not correct, and the camera recognition had reported wrong com-
ponent position on the pipet.
(Remedy)qCorrect size info..wIf the component is in the specifica-
tion, adjust the Co-Pl level in component info.eCorrect the shape
data.
(Meaning)Co-planarity checking function inspect a component along
to the rectangle shape which include the component size as its
inside, and it should not detect leads at the corner position of that
rectangle. Because co-planarity checking start and finish scanning
always at the corner position of that rectangle, if a lead is detected
at the start position or finish position, this error message appears
to inform the problem.
(Cause)qThe size definition of the component is wrong.wSome
obstacle so as bumper is at the corner position and had been
detected.eBecause some shape information so as number of leads
is not correct, and the camera recognition had reported wrong com-
ponent position on the pipet.
(Remedy)qCorrect size info..wIf the component is in the specifi-
cation, adjust the Co-Pl level in component info.eCorrect the shape
data.
(Meaning)The number of the leads detected by co-planarity check-
ing is different from the definition.
(Cause)qShape data in the component info. so as size, pitch, num-
ber of leads is wrong.wSome lead is off.eSome lead could not
detected by the laser scanning.
(Remedy)qCorrect the data in the SHAPE page.wDispose or re-
pair the component.eFirst, adjust the Co-Pl level in component
info. If the adjusting did not solve the problem, the lower surface of
the component is too dirty enough to be disposed or repaired.
(Meaning)The height of 2 neighbor leads in 1 side has too much
difference and is over the Co-Pl threshold.
(Cause)Some leads are damaged.
(Remedy)Dispose component, or repair the component, or use big-
ger value as Co-Pl threshold.
(Meaning)qA lead top is out of the tolerance in Co-Pl threshold
compare to the averaged line of the lead top in A side.wA lead top
is out of the tolerance in Co-Pl threshold compare to the averaged
surface of all leads of the component.
(Cause)A lead is damaged. Or the average height of all leads in A
side is out of the tolerance in Co-Pl threshold compare to the aver-
aged surface of all leads of the component.
(Remedy)Dispose component, or repair the component, or use big-
ger value as Co-Pl threshold.
(meaning)An emergency stop has occurred.
(cause)An emergency stop has occurred because of trouble with
the machine, or because the Emergency Stop button was pressed.
(remedy)Check safety factors and press the Ready button.
(meaning)This is not an error message.
(cause)None
(remedy)None
(meaning)The motor shaft has not completed its return to the origin
position.
(cause)A return to the origin position was not carried out after the
power supply was turned on.
(remedy)Use the command window to specify an origin position
return.
(meaning)This is not an error message.
(cause)None
(remedy)None
Ea00104
Ea00105
Ea00107
Ea00108
Ea00110
Ea00111
Ea00112
Ea00113
Ea00114
Ea00115
Ea00116
Ea00117
Ea00118
Ea00119
Ea00120
Ea00124
Be careful for Safety !!!
Machine axes will move to dump point.
[ENTER] : execute
[Others] : abort
Insert installation disk or upgrade disk to floppy drive,
and turn off the power, and turn on the power again.
This command had been disabled.
To install/upgrade software, start up [VIOS SOFTWARE
UTILITY] and execute next command.
2. Update of VIOS Soft
3. Installation of System Data
This command had been disabled.
To update system data backup, start up [VIOS SOFT-
WARE UTILITY] and execute next command.
4. Backup of System Data
RETURNING TO ORIGIN. PLEASE WAIT.....
Hit any key to RESET running, or..
Hit the [ESC] key not to RESET.
Now reading data.
Please wait a moment....
PCB DATA ERROR
No PCB selected.
This command is not (yet) available.
COMMAND ERROR
Now writing data.
Please wait a moment....
RESET is now active.
Please wait a moment....
Initializing All Production History
Please wait a moment....
Release the EMERGENCY switch and push the READY
key to activate the servo for searching the origin.
This command is not available when the machine is run-
ning. Please stop the machine first.
=== Now head vacuum is ON.===
After resetting, vacuum power will be OFF. If component
is on head, it is dangerous to drop component on that
spot independent of dumping way defined in Component
Information.
In case you don't want to drop it, push EMG-BOTTOM
and check safety, and please remove it.
This command is not available if machine is not reset.
Please reset the machine first.
(meaning)This is an axis movement warning message which ap-
pears when a component is discarded while the power supply is off,
or under other circumstances.
(cause)None
(remedy)To move the axis, press the Enter key. If the axis cannot be
moved because it is dangerous, press any other key.
(meaning)In order to upgrade the software, this indicates that the
Install disk or Upgrade disk should be inserted and the power sup-
ply turned off and then on again.
(cause)None
(remedy)With the disk inserted, turn the power supply off and then
on again.
(meaning)This command has been disable.
(cause)This command has been deleted.
(remedy)Use command of [VIOS SOFTWARE UTILITY]
(meaning)This command has been disable.
(cause)This command has been deleted.
(remedy)Use command of [VIOS SOFTWARE UTILITY]
(meaning)Return to origin position is in progress.
(cause)None
(remedy)None
(meaning)This is a confirmation message asking whether it is all
right to reset the system.
(cause)None
(remedy)To avoid a reset, press the ESC key.
(meaning)The system is waiting for the data reading process to end.
(cause)None
(remedy)Please wait.
(meaning)An attempt was made to run the system without specify-
ing a PCB name.
(cause)No PCB name has been specified.
(remedy)Specify the name of the PCB when the PCB being manu-
factured is switched.
(meaning)This command cannot be used.
(cause)A command was issued which cannot be used.
(remedy)Do not use this command.
(meaning)Data writing is in progress.
(cause)None
(remedy)Wait until the data writing process has been completed.
(meaning)A reset is in progress.
(cause)None
(remedy)Wait until the reset has been completed.
(meaning)The production history information is being initialized.
(cause)None
(remedy)Wait until the process has been completed.
(meaning)A return to the origin position cannot be executed be-
cause an emergency stop has occurred.
(cause)An attempt was made to execute a return to the origin posi-
tion during an emergency stop.
(remedy)Cancel the emergency stop and then select the return to
origin position command again.
(meaning)This command cannot be executed while the machine is
in operation.
(cause)A command was selected which cannot be executed during
automatic operation.
(remedy)Stop the machine before executing the command.
(meaning)A component had been picked up by the head when an
attempt was made to reset, so there is a possibility of the compo-
nent being dropped after the reset.
(cause)An attempt was made to reset with a component still on the
nozzle. An attempt was made to reset with the pickup valve of the
head still on.
(remedy)If a component has been picked up, release it before press-
ing the key.
(meaning)This command cannot be executed unless a reset has
been carried out.
(cause)A command was selected which cannot be executed with-
out carrying out a reset first.
(remedy)Carry out a reset before executing this command.
Ea -5
ERROR MESSAGES LIST
Ea
Ea00126
Ea00127
Ea00130
Ea00131
Ea00132
Ea00133
Ea00134
Ea00135
Ea00136
Ea00137
Ea00138
Ea00139
Ea00140
Ea00141
Ea00142
Ea00143
Initializing PCB counter.
Please wait a moment....
Changing Production Schedule
Please wait a moment....
PCB DATA ERROR
Failed to read data.
PCB DATA ERROR
No component data available for the mount data.
Mount data 765
PCB DATA ERROR
No fiducial data available for the mount point fiducial.
Mount data 765
Fiducial data 1
E0133
PCB DATA ERROR
Illegal head number.
Mount data 765
Head number 2
PCB DATA ERROR
It is illegal setting of badmark function that only using
PCB badmark. PCB badmark is useful to judge existence
of BLOCK or LOCAL badmark. So, you have to use PCB
badmark function with using BLOCK badmark or LOCAL
badmark.
PCB DATA ERROR
No mark data available for the mount point fiducial.
Mount data 765
Fiducial data 1
Mark data 1
PCB DATA ERROR
No mark data available for the PCB fiducial.
Mark data 1
PCB DATA ERROR
No mark data available for the BLOCK fiducial.
Mark data 1
PCB DATA ERROR
No mark data available for the PCB or BLOCK badmark.
Mark data 1
PCB DATA ERROR
Illegal feeder set number or feeder type.
Mount data 765
Component data 150
PCB DATA ERROR
Illegal feeder type.
Mount data 765
Component data 150
PCB DATA ERROR
Mount position is outside moving area.
Mount data 765
Axes X1
PCB DATA ERROR
Fiducial position is outside moving area.
Mount data 765
Fiducial data 1
Axes X1
PCB DATA ERROR
PCB fiducial position is outside moving area.
Axes X1
(meaning)The PCB counter is being initialized.
(cause)None
(remedy)Wait until the initialization has been completed.
(meaning)The PCB counter is being changed.
(cause)None
(remedy)Wait until the process has been completed.
(meaning)An error occurred when reading the PCB data.
(cause)A PCB with an asterisk (*) was selected, or the PCB data
has been destroyed.
(remedy)
(meaning)The component specified in the mounting data does not
exist.
(cause)The component data for the component being used is not
the PCB data.
(remedy)Create the component data specified by the mounting data.
(meaning)Fiducial data does not exist.
(cause)The fiducial data specified by the mounting data does not
exist.
(remedy)Create the data for the fiducial coordinates.
(meaning)The specified head number cannot be accommodated.
(cause)A head number has been specified which is not correct.
(remedy)Change the head number to the correct one
.
(meaning)The PCB data is only using PCB badmark.
(cause) The PCB data is only using PCB badmark.
(remedy)Change PCB data to use other badmark, or not to use
PCB badmark.
(meaning)No data exists for the specified fiducial mark.
(cause)No mark data exists.
(remedy)Create the specified mark data.
(meaning)The mark data for the specified fiducial does not exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)No mark data exists that corresponds to the block fidu-
cial.
(cause)The specified mark data does not exist.
(remedy)Create the specified mark data.
(meaning) No mark data exists that corresponds to the bad mark.
(cause)The specified mark data does not exist.
(remedy)Create the specified mark data.
(meaning)A feeder setting position has been specified which is not
correct, or a feeder is interfering with operation.
(cause)A feeder has been set in a position which interferes with the
adjacent feeder, or the feeder setting is erroneous.
(remedy)Check the feeder setting number or the type of feeder,
and change it to the correct one.
(meaning)The feeder type specified in the fixed component infor-
mation is different from that specified in the PCB data.
(cause)The feeder type specified in the fixed component informa-
tion does not match that specified in the PCB data.
(remedy)Make sure the feeder type specified in the fixed compo-
nent information matches that specified in the PCB data.
(meaning)The mounting position interferes with the soft limit.
(cause)An incorrect value has been entered for the mounting posi-
tion, or an attempt was made to mount components with a head
that does not reach far enough.
(remedy)Check the mounting position data. Use a head which ex-
tends far enough to reach the mounting position.
(meaning)The fiducial mark position interferes with the soft limit.
(cause)There is something wrong with the data that has been en-
tered for the fiducial mark coordinates.
(remedy)Correct the fiducial mark coordinates.
(meaning)The coordinates of the PCB fiducial mark are not within
the soft limit.
(cause)An incorrect value has been entered for the fiducial mark
coordinates.
(remedy)Check the fiducial mark coordinate data.
Ea00144
Ea00145
Ea00146
Ea00147
Ea00148
Ea00149
Ea00150
Ea00151
Ea00152
Ea00153
Ea00154
PCB DATA ERROR
BLOCK fiducial position is outside moving area.
Axes X1
PCB DATA ERROR
Bad mark position is outside moving area.
Axes X1
PCB DATA ERROR
Pickup position is outside moving area.
Mount data 765
Component data 150
Axes X1
PCB DATA ERROR
Illegal head-component combination.
Mount data 765
Component data 150
Head number 2
Checking PCB and BLOCK fiducial data.
Please wait a moment......
Block number
Checking mount data.
Please wait a moment.......
Mount data
Block number
PCB DATA ERROR
Illegal component shape data or component data is not
defined.
Component data 150
If this component is "FixCmpRef.", execute "FIXED COMP.
MATCH" in "DATA_GENERATOR". Input the "Alignment
Type" of "Component Inf.".
If execute the "AUTO DISTRIBUTION", execute the
opitmization of each machine.
Current nozzles on heads are different from the nozzles
necessary for this PCB.A TABLE:[Upper = Head No.,
Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
Please check each heads equipped with nozzles as
shown below.
A TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
B TABLE:[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Nzl. 1 1 1 2 2 2 2 2 2 2 2 3 3 4 4 5
PCB DATA ERROR
Setting of the alignment module is not correct.
One of the following could cause this error:
- Alignment module is not specified
- Alignment module is not equipped.
- Alignment module cannot handle this component.
Component data 150
PCB DATA ERROR
The nozzle for the head specified in the mount data is
already assigned to other component type. The compo-
nent cannot be handled by this nozzle.
Mount data 765
Component data 150
(meaning)The block fiducial position is not within the soft limit.
(cause)An incorrect value has been entered for the block fiducial
mark coordinates, or for the block repeat values.
(remedy)Check the data for the block fiducial coordinates and the
block repeat coordinates.
(meaning)The bad mark coordinates are not within the soft limit.
(cause)An incorrect value has been entered for the bad mark coor-
dinates.
(remedy)Check the bad mark coordinate position.
(meaning)The pickup position is not within the soft limit.
(cause)A head number has been selected which cannot be used
for picking up components, or the teaching function has been se-
lected and an incorrect value has been entered for the coordinates.
(remedy)Check to make sure the head number can be used for
pickup, and if the teaching function is being used, check the coordi-
nates.
(meaning)The head being used cannot be used to pick up compo-
nents.
(cause)A head has been specified to pick up components with which
a different nozzle is already being used, or a nozzle which can be
used to pick up the components has not been attached to the head.
(remedy)Go back to the editing screen and change the head num-
ber.
(meaning)This is not an error message; the PCB fiducial and block
fiducial data are being checked.
(cause)None
(remedy)Wait until the check has been completed.
(meaning)The mounting data is being checked. This is not an error
message.
(cause)None
(remedy)Wait until the check has been completed.
(meaning)The settings for the component shape information are
not correct, or the component data itself has not been specified.
(cause)The component shape information has not been specified
correctly, or the component data has not been defined.
(remedy)Go back to the editing screen and see if the component
data has been are correct. If using FixCmpRef.", execute "FIXED
COMP.MATCH". If executing "AUTO DISTRIBUTION", the number
of component is different. Execute the optimization of each ma-
chine.
(meaning)The nozzles which are currently attached are not the right
combination for the PCB about to be manufactured.
(cause)The wrong combination of nozzles was used when the setup
was changed.
(remedy)Attach the correct nozzles, following the instructions on
the display.
(meaning)This is the display showing the nozzle settings required
for the PCB about to be manufactured. It is not an error message.
(cause)None
(remedy)Check to make sure the nozzles which have been speci-
fied match those displayed before starting production.
(meaning)The settings for the recognition unit are not correct.
(cause)The recognition unit has not been specified in the compo-
nent data; a recognition unit which does not actually exist has been
specified in the component data; or the component is one which
cannot be recognized with the specified recognition unit.
(remedy)Go back to the editing screen and specify the correct rec-
ognition unit.
(meaning)The head specified in the mounting data is already being
used with different nozzles for other components, and nozzles can-
not be specified for picking up the currently specified components.
(cause)An attempt was made to use the same head to pick up com-
ponents which require different nozzles.
(remedy)Go back to the editing screen and change the head num-
ber.
Ea -6
ERROR MESSAGES LIST
Ea
Ea00155
Ea00156
Ea00157
Ea00158
Ea00159
Ea00160
Ea00161
Ea00162
Ea00163
Ea00164
Ea00165
PLEASE CHECK FOR ANY ILLEGAL RUNNING CON-
DITION
Check followings. If all OK, please continue.
ProductionShould be [WithVacChk].
Vision AlignShould be [UseVision].
PCB Fix Device Not Equipped device is not available.
Ent. Stopper Available if is equipped.
PCB Trans Mode Should be [Normal].
PCB Size is not within range.
PCB DATA ERROR
The nozzle for the component specified in the mount data
does not exist in nozzle station.
Mount data 765
Component data 150
PCB DATA ERROR
The head specified in the mount data cannot align the
component.
Mount data 765
Component data 150
COMPONENT DATA ERROR
Feeder Position must be Teaching for tray feeder compo-
nent.
Mount data 765
Component data 150
PCB DATA ERROR
The mount data has a component that cannot be attached
to the specified nozzle type.
Mount data 765
Component data 150
PCB DATA ERROR
The component cannot be handled by any nozzle.
Mount data 765
Component data 150
PCB DATA ERROR
The component size is bigger than the laser window size
of LASER alignment module.
Mount data 765
Component data 150
PCB DATA ERROR
Illegal Comp.Amount or TrayAmount
Specified in the component data.
In case using "Alternate Component" function or "Count
Out Stop", Y-Component Amount in TRAY information is
necessary to input data.
Mount data
Component data
Name
PCB DATA ERROR
Illegal Pallet-Start and Last number specified in the com-
ponent data.
Mount data 765
Component data 150
PCB DATA ERROR
Pickup position in tray unit is outside the moving area.
Mount data 765
Component data 150
axes LX
PCB DATA ERROR
Too much local fiducial data are found.
(meaning)The operating conditions which have been specified are
not appropriate for production.
(cause)The production conditions have not been set for a vacuum
check; the regular image processing correction is not being used; a
PCB securing method has been selected which is not available
with the machine; the regular transport mode is not being used; or
the PCB size is not within the specifications.
(remedy)Go back to the editing screen and change the operating
conditions, or change the settings for the operating conditions.
(meaning)The nozzle used with the components specified in the
mounting data does not exist in the nozzle station.
(cause)The head setting is wrong and a nozzle which can be used
to pick up the components does not exist in the nozzle station, or
the component setting is wrong and there is no nozzle which can
be used to pick up the components.
(remedy)Go back to the editing screen and check the mounting
and component data.
(meaning)The head specified in the mounting data does not corre-
spond to the recognition unit which corresponds to the components.
(cause)The wrong head number has been specified, or the wrong
recognition unit has been specified.
(remedy)Go back to the editing screen and correct the recognition
unit or the head number.
(meaning)Teaching must be used for the position at which tray com-
ponents to be picked up.
(cause)The pickup position coordinates have been specified auto-
matically.
(remedy)Go back to the editing screen and use teaching to change
the pickup position coordinates. Also use teaching to correct the
pickup coordinates.
(meaning)The head specified in the mounting data does not con-
tain the right nozzle for picking up the specified components.
(cause)The wrong head number has been specified, or the wrong
nozzle has been specified for use with the components.
(remedy)Go back to the editing screen and edit the mounting data
or the component data.
(meaning)No nozzle exists which can be used to pick up the com-
ponents specified in the mounting data.
(cause)There is a problem with the specification of the pickup nozzle
in the component data.
(remedy)Go back to the editing screen and edit the component
data.
(meaning)The components specified in the mounting data are out-
side of the range for which laser recognition is possible.
(cause)An attempt was made to use laser recognition with compo-
nents which are too big.
(remedy)Go back to the editing screen and change the recognition
unit.
(meaning) Setting for number of components or number of trays in
component data is incorrect.
(cause) Number of components or number of trays has not been
specified, or illegal value has been set.
(remedy) Go back to edit screen and edit number of components
or number of trays.
(meaning)There is a problem with the starting or ending pallet num-
ber in the component data.
(cause)A number which does not exist has been specified as the
starting or ending pallet number, or an ending number has been
specified which is larger than the starting number.
(remedy)Go back to the editing screen and edit the starting or end-
ing pallet number.
(meaning)The pickup position for components in the external tray
is not within the movement range of the external tray axis.
(cause)The coordinates for the pickup position in the component
data are not appropriate.
(remedy)Go back to the editing screen and re-teach the pickup
position.
(meaning)The number of local fiducial data exceeds the allowable
limit.
(cause)The number of local fiducial is too large.
(remedy)Go back to the editing screen and reduce the number of
local fiducial being used.
Ea00166
Ea00167
Ea00168
Ea00169
Ea00170
Ea00171
Ea00172
Ea00173
Ea00174
Ea00175
Ea00176
PCB DATA ERROR
This machine is not equipped with a Dump station.
Component data 150
NO COMPONENT
Hit the [ESC] key to go next step. Hit the [ENTER] key to
recover this component again.
Mount data 765
Component data 150
PCB DATA ERROR
PCB BADMARK, BLOCK BADMARK, LOCAL
BADMARK and PRECEDING PICKING cannot be ex-
ecuted at the same time.
PCB DATA ERROR
You can't use alternative component function for tray com-
ponent.
Mount data 765
Component data 150
PCB DATA ERROR
Alternative component is on the different table from the
original one.
Mount data 765
Component data 150
PCB DATA ERROR
Required Nozzle for alternative component is different
from original one.
Mount data 765
Component data 150
Component runs out.
Will you switch component?
Press [ENTER] to switch, others not to.
Current component 150
Feeder set position 21
Alternative component 151
Feeder set position 22
PCB DATA ERROR
Feeder Type for alternative component is different from
original one.
Mount data 765
Component data 150
PCB DATA ERROR
Setting for alternative component must end original one.
Mount data 765
Component data 150
PCB DATA ERROR
When using component check function, there must be
PriDispense data which is pointed by fiducial number in
mount data.
Mount data 765
PreDispense data 1
PCB DATA ERROR
When using component check function, Mark number in
Predispense data must be set which is used by mount
data.
Mount data 765
PreDispense data 1
(meaning)A dump station has been specified in the component data
even though no dump station has been installed in the machine.
(cause)Same as above.
(remedy)Go back to the editing screen and change the dump method
specified in the component data.
(meaning)When the PCB was checked for components following
placing, no components were found on it.
(cause)There was an error in placing earlier components on the
PCB, or the sensor has not been adjusted correctly.
(remedy)If the error has occurred even though components were
actually placed on the PCB, simply press the ESC key. If no compo-
nents have actually been placed on the PCB, press the Enter key to
place those components once again.
(meaning)When the bad mark function is being used, the preced-
ing picking function cannot be used.
(cause)The bad mark and preceding picking functions cannot be
used in combination.
(remedy)Go back to the editing screen and cancel either the pre-
ceding pickup function or the bad mark function.
(meaning)The alternative component function has been indicated
when there are no more components left on the tray.
(cause)Same as above.
(remedy)Go back to the editing screen and set a value of "0" for the
alternative component function.
(meaning)The tables for the original components and the alterna-
tive components are different.
(cause)The original components have been specified for Table A
and the alternative components for Table B, or the reverse.
(remedy)Go back to the editing screen and change the feeder set-
ting number in the component data, so that movement is made to
the same table.
(meaning)Different nozzles have been specified for the original com-
ponents and the alternative components.
(cause)Same as above.
(remedy)Go back to the editing screen and check the nozzle set-
ting in the component data.
(meaning)The components have been judged as having run out,
because of a pickup error. This asks whether or not alternative com-
ponents should be used
(cause)Because of a pickup error, the system has decided that com-
ponents have run out. To change to alternative components, press
the Enter key. If not changing to alternative components, press any
other key to continue using the original components. If original com-
ponents still exist but cannot be picked up because of a problem
with the feeder or for another reason, a change to alternative com-
ponents cannot be executed.
(remedy)Check the feeder status and either switch to alternative
components, or continue using the original components.
(meaning)The feeder containing the alternative components is dif-
ferent from that containing the original components.
(cause)Same as above.
(remedy)Go back to the editing screen and change the feeder be-
ing used in the component data.
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)The check coordinates specified by the point fiducial num-
ber in the placing data are not included in the pre-dispensing data.
(remedy)Create the check coordinates in the pre-dispensing data.
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)No mounting data number has been specified in the pre-
dispensing data which contains the check coordinates.
(remedy)Specify the mounting data number in the pre-dispensing
data.