YAMAHA errer code-a.pdf - 第7页

Ea - 7 ERROR MESSAGES LIST Ea Ea00177 Ea00178 Ea00179 Ea00180 Ea00181 Ea00182 Ea00183 Ea00184 Ea00185 Ea00186 Ea00187 Ea00189 Ea00190 PCB DA TA ERROR When using component check function, you must pre- pare some Mark data…

100%1 / 42
Ea -6
ERROR MESSAGES LIST
Ea
Ea00155
Ea00156
Ea00157
Ea00158
Ea00159
Ea00160
Ea00161
Ea00162
Ea00163
Ea00164
Ea00165
PLEASE CHECK FOR ANY ILLEGAL RUNNING CON-
DITION
Check followings. If all OK, please continue.
ProductionShould be [WithVacChk].
Vision AlignShould be [UseVision].
PCB Fix Device Not Equipped device is not available.
Ent. Stopper Available if is equipped.
PCB Trans Mode Should be [Normal].
PCB Size is not within range.
PCB DATA ERROR
The nozzle for the component specified in the mount data
does not exist in nozzle station.
Mount data 765
Component data 150
PCB DATA ERROR
The head specified in the mount data cannot align the
component.
Mount data 765
Component data 150
COMPONENT DATA ERROR
Feeder Position must be Teaching for tray feeder compo-
nent.
Mount data 765
Component data 150
PCB DATA ERROR
The mount data has a component that cannot be attached
to the specified nozzle type.
Mount data 765
Component data 150
PCB DATA ERROR
The component cannot be handled by any nozzle.
Mount data 765
Component data 150
PCB DATA ERROR
The component size is bigger than the laser window size
of LASER alignment module.
Mount data 765
Component data 150
PCB DATA ERROR
Illegal Comp.Amount or TrayAmount
Specified in the component data.
In case using "Alternate Component" function or "Count
Out Stop", Y-Component Amount in TRAY information is
necessary to input data.
Mount data
Component data
Name
PCB DATA ERROR
Illegal Pallet-Start and Last number specified in the com-
ponent data.
Mount data 765
Component data 150
PCB DATA ERROR
Pickup position in tray unit is outside the moving area.
Mount data 765
Component data 150
axes LX
PCB DATA ERROR
Too much local fiducial data are found.
(meaning)The operating conditions which have been specified are
not appropriate for production.
(cause)The production conditions have not been set for a vacuum
check; the regular image processing correction is not being used; a
PCB securing method has been selected which is not available
with the machine; the regular transport mode is not being used; or
the PCB size is not within the specifications.
(remedy)Go back to the editing screen and change the operating
conditions, or change the settings for the operating conditions.
(meaning)The nozzle used with the components specified in the
mounting data does not exist in the nozzle station.
(cause)The head setting is wrong and a nozzle which can be used
to pick up the components does not exist in the nozzle station, or
the component setting is wrong and there is no nozzle which can
be used to pick up the components.
(remedy)Go back to the editing screen and check the mounting
and component data.
(meaning)The head specified in the mounting data does not corre-
spond to the recognition unit which corresponds to the components.
(cause)The wrong head number has been specified, or the wrong
recognition unit has been specified.
(remedy)Go back to the editing screen and correct the recognition
unit or the head number.
(meaning)Teaching must be used for the position at which tray com-
ponents to be picked up.
(cause)The pickup position coordinates have been specified auto-
matically.
(remedy)Go back to the editing screen and use teaching to change
the pickup position coordinates. Also use teaching to correct the
pickup coordinates.
(meaning)The head specified in the mounting data does not con-
tain the right nozzle for picking up the specified components.
(cause)The wrong head number has been specified, or the wrong
nozzle has been specified for use with the components.
(remedy)Go back to the editing screen and edit the mounting data
or the component data.
(meaning)No nozzle exists which can be used to pick up the com-
ponents specified in the mounting data.
(cause)There is a problem with the specification of the pickup nozzle
in the component data.
(remedy)Go back to the editing screen and edit the component
data.
(meaning)The components specified in the mounting data are out-
side of the range for which laser recognition is possible.
(cause)An attempt was made to use laser recognition with compo-
nents which are too big.
(remedy)Go back to the editing screen and change the recognition
unit.
(meaning) Setting for number of components or number of trays in
component data is incorrect.
(cause) Number of components or number of trays has not been
specified, or illegal value has been set.
(remedy) Go back to edit screen and edit number of components
or number of trays.
(meaning)There is a problem with the starting or ending pallet num-
ber in the component data.
(cause)A number which does not exist has been specified as the
starting or ending pallet number, or an ending number has been
specified which is larger than the starting number.
(remedy)Go back to the editing screen and edit the starting or end-
ing pallet number.
(meaning)The pickup position for components in the external tray
is not within the movement range of the external tray axis.
(cause)The coordinates for the pickup position in the component
data are not appropriate.
(remedy)Go back to the editing screen and re-teach the pickup
position.
(meaning)The number of local fiducial data exceeds the allowable
limit.
(cause)The number of local fiducial is too large.
(remedy)Go back to the editing screen and reduce the number of
local fiducial being used.
Ea00166
Ea00167
Ea00168
Ea00169
Ea00170
Ea00171
Ea00172
Ea00173
Ea00174
Ea00175
Ea00176
PCB DATA ERROR
This machine is not equipped with a Dump station.
Component data 150
NO COMPONENT
Hit the [ESC] key to go next step. Hit the [ENTER] key to
recover this component again.
Mount data 765
Component data 150
PCB DATA ERROR
PCB BADMARK, BLOCK BADMARK, LOCAL
BADMARK and PRECEDING PICKING cannot be ex-
ecuted at the same time.
PCB DATA ERROR
You can't use alternative component function for tray com-
ponent.
Mount data 765
Component data 150
PCB DATA ERROR
Alternative component is on the different table from the
original one.
Mount data 765
Component data 150
PCB DATA ERROR
Required Nozzle for alternative component is different
from original one.
Mount data 765
Component data 150
Component runs out.
Will you switch component?
Press [ENTER] to switch, others not to.
Current component 150
Feeder set position 21
Alternative component 151
Feeder set position 22
PCB DATA ERROR
Feeder Type for alternative component is different from
original one.
Mount data 765
Component data 150
PCB DATA ERROR
Setting for alternative component must end original one.
Mount data 765
Component data 150
PCB DATA ERROR
When using component check function, there must be
PriDispense data which is pointed by fiducial number in
mount data.
Mount data 765
PreDispense data 1
PCB DATA ERROR
When using component check function, Mark number in
Predispense data must be set which is used by mount
data.
Mount data 765
PreDispense data 1
(meaning)A dump station has been specified in the component data
even though no dump station has been installed in the machine.
(cause)Same as above.
(remedy)Go back to the editing screen and change the dump method
specified in the component data.
(meaning)When the PCB was checked for components following
placing, no components were found on it.
(cause)There was an error in placing earlier components on the
PCB, or the sensor has not been adjusted correctly.
(remedy)If the error has occurred even though components were
actually placed on the PCB, simply press the ESC key. If no compo-
nents have actually been placed on the PCB, press the Enter key to
place those components once again.
(meaning)When the bad mark function is being used, the preced-
ing picking function cannot be used.
(cause)The bad mark and preceding picking functions cannot be
used in combination.
(remedy)Go back to the editing screen and cancel either the pre-
ceding pickup function or the bad mark function.
(meaning)The alternative component function has been indicated
when there are no more components left on the tray.
(cause)Same as above.
(remedy)Go back to the editing screen and set a value of "0" for the
alternative component function.
(meaning)The tables for the original components and the alterna-
tive components are different.
(cause)The original components have been specified for Table A
and the alternative components for Table B, or the reverse.
(remedy)Go back to the editing screen and change the feeder set-
ting number in the component data, so that movement is made to
the same table.
(meaning)Different nozzles have been specified for the original com-
ponents and the alternative components.
(cause)Same as above.
(remedy)Go back to the editing screen and check the nozzle set-
ting in the component data.
(meaning)The components have been judged as having run out,
because of a pickup error. This asks whether or not alternative com-
ponents should be used
(cause)Because of a pickup error, the system has decided that com-
ponents have run out. To change to alternative components, press
the Enter key. If not changing to alternative components, press any
other key to continue using the original components. If original com-
ponents still exist but cannot be picked up because of a problem
with the feeder or for another reason, a change to alternative com-
ponents cannot be executed.
(remedy)Check the feeder status and either switch to alternative
components, or continue using the original components.
(meaning)The feeder containing the alternative components is dif-
ferent from that containing the original components.
(cause)Same as above.
(remedy)Go back to the editing screen and change the feeder be-
ing used in the component data.
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)The check coordinates specified by the point fiducial num-
ber in the placing data are not included in the pre-dispensing data.
(remedy)Create the check coordinates in the pre-dispensing data.
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)No mounting data number has been specified in the pre-
dispensing data which contains the check coordinates.
(remedy)Specify the mounting data number in the pre-dispensing
data.
Ea -7
ERROR MESSAGES LIST
Ea
Ea00177
Ea00178
Ea00179
Ea00180
Ea00181
Ea00182
Ea00183
Ea00184
Ea00185
Ea00186
Ea00187
Ea00189
Ea00190
PCB DATA ERROR
When using component check function, you must pre-
pare some Mark data. But it doesn't exist or is not suit-
able.
Mount data 765
PreDispense data 1
Mark data 1
PCB DATA ERROR
CountOutStop must be same among alternative compo-
nents group.
Mount data 765
Component data 150
PCB DATA ERROR
Specified alternative component doesn't exist.
Mount data 765
Component data 150
PCB DATA ERROR
Feeder type of the component is different from the one of
the fixed component data.
Mount data 765
Component data 150
PCB DATA ERROR
Failed to read the fixed component data.
Mount data 765
Component data 150
PCB DATA ERROR
Specified fixed component doesn't exist.
Mount data 765
Component data 150
PCB DATA ERROR
The number of block repeat data exceeds limitation.
Maximum quantity is 765 .
PCB DATA ERROR
Component Name must be same among alternative com-
ponents group.
Mount data 765
Component data 150
PCB DATA ERROR
Usage of UpdateGroupNo must be same among alterna-
tive components group.
Mount data 765
Component data 150
PCB DATA ERROR
Local badmark position is outside moving area.
Mount data 3
Local Badmark data 5
Axes X
PCB DATA ERROR
No mark data available for the local badmark. Or the mark
data is not for badmark.
Mount data 7
Mark data 2
PCB DATA ERROR
Pickup position is outside moving area for soft landing
motion.
Mount data 765
Component data 150
Axes Z1
PCB DATA ERROR
Mount position is outside moving area for soft landing
motion.
Mount data 765
Component data 150
Axes Z1
(meaning)When using the component check function, which is a
special function there is a problem with the PCB data.
(cause)No mark information for bad marks has been specified in
the pre-dispensing data which contains the check coordinates.
(remedy)Create the mark information for the bad marks.
(meaning)Components which are organized in a series by the al-
ternative component settings do not have the same count stop set-
tings.
(cause)Alternative components in a series have different count stop
settings, so they will either stop or not stop.
(remedy)Standardize the settings.
(meaning)The specified alternative components do not exist.
(cause)There are no alternative components that match the set-
ting.
(remedy)When using alternative components, create data for the
alternative components corresponding to the specified number, or
do not specify alternative components.
(meaning)The feeder type specified in the PCB data is different
from that in the fixed components data.
(cause)A different type of feeder has been specified in the PCB
data from that specified in the fixed components data.
(remedy)Change one setting or the other so that they match.
(meaning)An error occurred when reading the fixed component data.
(cause)No fixed component data file exists in the machine, or the
fixed components data file has been destroyed.
(remedy)Copy the fixed component data from the backup disk.
(meaning)The specified component data does not exist.
(cause)The fixed component data corresponding to the fixed com-
ponent data number specified in the mounting data does not exist.
(remedy)Do not use the fixed component data, or create new fixed
component data.
(meaning)The number of block repeats exceeds the rated limit.
(cause)The specified number of block repeats exceeds the maxi-
mum limit of 512.
(remedy)Specify a number of block repeats that is 512 or less.
(meaning)The names of several components in a series of alterna-
tive components are different.
(cause)The names of all alternative components must be the same.
(remedy)Specify the names of alternative components linked in a
series so that all of the names are the same.
(meaning)In the component data for a series of alternative compo-
nents, there are some data which refer to fixed component data
and some which do not.
(cause)With alternative components, the fixed component data ref-
erences for series component data must be the same.
(remedy)Standardize the settings so that the fixed component data
is either referenced or not referenced for all of the alternative com-
ponent data in the series.
Please input correct position of Local Badmark.
(meaning)The mark data for the specified not an badmark does not
exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)QFP components cannot be picked up using this mount-
ing method because of an incorrect setting in the pickup heights.
(cause)
(remedy)Check the settings for pickup heights.
(meaning)When the QFP mounting method is being used, the
mounting position height is not within the soft limit.
(cause)When the QFP mounting method is being used, the setting
for the mounting position height is outside of the soft limit.
(remedy)Check the setting for the mounting position height.
Ea00191
Ea00192
Ea00193
Ea00194
Ea00195
Ea00197
Ea00198
Ea00199
Ea00200
Ea00201
Ea00202
Ea00203
PCB DATA ERROR
No nozzle to attach to the head.
AxisTable A
Head 2
The number of possessed nozzle may not be enough.
Current nozzles on heads are different from the nozzles
necessary for this PCB.XY TABLE[Upper = Head No.,
Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
Please check each heads equipped with nozzles as
shown below.
XY TABLE[Upper = Head No., Lower = Nozzle Type]
Head 1 2 3 4 5 6 7 8
Nzl. 1 1 1 2 2 2 2 2
PCB DATA ERROR
Component will interfere with other nozzles.
Mount data 765
Component data 150
Head 2
PCB DATA ERROR
PCB width is outside moving area.
Axes LW
PCB SIZE ERROR
Width of PCB is out of range.
SpDat[PLTnum_inf0](mm)
<
=
[PCB Width]
<
=
SpDat[PLTnum_inf1](mm)
Please set width of PCB again.
PCB DATA ERROR
No local badmark data is set to "Note" for executable
mounting data. During production, "Note" data is ignored.
So if you want to use local badmark function, set this "
Exec". If not, set "0" for BadMk in mounting data.
Mount Data 6
Local Badmark Data 3
PCB DATA ERROR
The PCB has too many mount data.
NOZZLE CHANGE ERROR
Failed to pick up a nozzle. Please check the sensor of
the nozzle station and adjust height, angle and position
data of the nozzle station.
Head No. 2
Station No. 11
NOZZLE CHANGE ERROR
Failed to store a nozzle. Please check the sensor of nozzle
station and adjust height, angle and position data of the
nozzle station.
Head No. 2
Station No. 11
DOWNLOAD WINDOW DATA ERROR
Failed to download the window data of the laser unit.
Please Power OFF the machine and check the connec-
tion of the laser unit.
NOZZLE STATION ERROR
One or more nozzle(s) are not present on the nozzle sta-
tion. Please check the sensors of the nozzle station and
insert the appropriate nozzle(s).
Head No. 2
(meaning)The specified nozzle cannot be attached to the head.
(cause)Because the setting for the number of nozzles is wrong, there
are not enough nozzles to be attached to the head, or it is not pos-
sible to use more than the current number of nozzles.
(remedy)If the nozzles are available, change the setting for the num-
ber of nozzles In any other case, create PCB data which does not
specify a head using the same nozzles.
(meaning)The nozzles which are currently attached are not the right
combination for the PCB about to be manufactured.
(cause)The wrong combination of nozzles was used when the setup
was changed.
(remedy)Attach the correct nozzles, following the instructions on
the display.
(meaning)This is the display showing the nozzle settings required
for the PCB about to be manufactured. It is not an error message.
(cause)None
(remedy)Check to make sure the nozzles which have been speci-
fied match those displayed before starting production.
(meaning)The component is interfering with the adjacent nozzle.
(cause)Because the component is large, it is interfering with the
nozzle next to it.
(remedy)Create the appropriate data and try again.
(meaning)The PCB width is not within the soft limit.
(cause)An attempt was made to use a PCB which is not within the
specifications, or there is something wrong with the PCB width set-
ting.
(remedy)Check the PCB width setting.
(meaning) PCB width is out of range being used.
(cause) PCB width has not been set within a range of $$$ mm (mini-
mum) to ### mm (maximum).
(remedy) Set PCB width to value within a range of $$$ mm to ###
mm.
If you want to use local badmark function. Set "skip?" parameter
"Exec". If you don't want to use set "0" in mount data
(meaning)The nr. of mount data exceeds limit.
(cause)The nr. of mount data exceeds limit.
(remedy)Delete some mount data. Or delete some skip data in block
repeat and etc.
(meaning)The nozzle could not be picked up.
(cause)The nozzle station sensor may be defective, or the height,
angle, or XY coordinates may not have been correctly adjusted in
the nozzle station information.
(remedy)Adjust the sensor. Also, re-adjust the nozzle position, angle,
and height in the nozzle station information.
(meaning)An error occurred when housing the nozzle.
(cause)The nozzle station sensor may be defective, or the height,
angle, or XY coordinates may not have been correctly adjusted in
the nozzle station information.
(remedy)Check the operation of the nozzle station sensor. Also, re-
adjust the nozzle position, angle, and height in the nozzle station
information.
(meaning)An error occurred when transferring window data to the
laser recognition unit.
(cause)An error occurred in sending the data because of noise or
another factor, or the laser recognition unit has become disconnected
from the I/O board.
(remedy)Check the laser recognition unit connections, and then turn
the power supply off and try running the machine again. Check to
see how often the problem occurs, and contact the manufacturer if
necessary.
(meaning)Several nozzles are produced from the nozzle station of
the specified head.
(cause)The nozzle station sensor may be defective, or several
nozzles have been removed from the nozzle station.
(remedy)Make sure the correct nozzles are stored in the nozzle
station, or check the operation of the nozzle station sensor.
Ea -8
ERROR MESSAGES LIST
Ea
Ea00204
|
Ea00205
Ea00206
Ea00207
Ea00220
Ea00221
Ea00222
Ea00223
Ea00230
Ea00231
Ea00232
NOZZLE STATION ERROR
There is no nozzle present for next sequence. Please
check nozzle station data.
Head No. 2
Station No. 11
NOZZLE STATION ERROR
There is more than one nozzle for next sequence. Please
check sensors of the nozzle station and insert the appro-
priate nozzle(s).
Head No. 2
Station No. 11
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
DATA ERROR
The next mount sequence specifies that more than three
heads are used or the head number used is 3 or more.
Please check the mount data.
BACKLIGHT POSITION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. and pull up no.2 head to up-end, push
down no.1 head to lower pos.
4. In case the step 1-3 had not solved problem, Please
move backlight to right position by CHANGE BACKLIGHT
command.
NOZZLE CHANGE ERROR
Now, head is picking the component. Head can't change
the nozzle.
OPERATION ERROR
1. Ensure all nozzles not in use are in station.
2. Ensure the sensor knows nozzles are there.
3. Push EMG sw. Check the safety of head, nozzles,
nozzle station.
4. In case the step 1-3 had not solved problem, Please
ensure safety by manual.
NOZZLE STATION CLAMPING ERROR
Unable to clamp nozzles in the nozzle station.
Correct the condition of the nozzle station.
4-Point Fiducial Data Error
Fiducial No.5
6
Setting of [Type] is not correct. Please set like this,
No. 5 --> [4Local-M]
No. 6 --> [4Local-S]
4-Point Fiducial Data Error
Fiducial No.5
6
Fiducial No.5
6
Setting of [Mark] is not correct. Please set same number.
4-Point Fiducial Data Error
Fiducial No.5
6
Distance between point and another point is too short.
Please set this distance more than 5(mm). Please set
coordinates of 4-point again.
(meaning)The nozzle intended for use is not in the nozzle station.
(cause)The nozzle which is planned for use has not been specified
in the nozzle station information.
(remedy)Check the settings in the nozzle station information.
(meaning)The nozzle station contains more than one of the same
nozzle.
(cause)Two of the same nozzle have been specified in the nozzle
station information.
(remedy)Check the nozzle station information.
(meaning)A head number of 3 or higher has been specified in the
mounting data for a mounter which has only two heads.
(cause)A head number of 3 or more has been specified.
(remedy)Change the head number in the placing data to 1 or 2.
(meaning)Vision recognition is specified with head 2.
(cause)With this machine, vision recognition cannot be carried out
using head 2.
(remedy)Change the head number to 1, or change to laser recog-
nition.
(meaning)The backlighting illumination is dangerously positioned.
(cause)When an attempt was made to change nozzles, the nozzles
could not be changed because the position of the backlighting illu-
mination was dangerous.
(remedy)Check to see that all of the nozzles are in the nozzle sta-
tion, and that the sensor reacts to all of the nozzles in the nozzle
station. Next, press the Emergency Stop button and move head 2
to its upper end and head 1 below the backlighting illumination
Then use the backlighting illumination movement command to move
the backlighting illumination to the right.
(meaning)The nozzle cannot be replaced because a component
has been picked up.
(cause)Two causes are possible: the head vacuum is on, or the
head vacuum is on and a component has been detected by the
vacuum level sensor.
(remedy)Remove the component from the nozzle or turn off the
head vacuum.
Accident happened for YV-120 machine Nozzle changing is failed.
According to the message and recover this accident
(meaning)Although the upper plate of the nozzle station slides and
two sensor for both edge (only single side for YVL80) detect the
actual action of the plate, at least 1 sensor do not response to the
command to slide the plate.
(cause)qPlate is mechanically stuck. The position or the sensitivity
of the sensor is not adjusted.
(remedy)Repair the sliding plate, or adjust the sensor.
Please set fiducial data according to "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Ea00233
Ea00234
Ea00235
Ea00236
Ea00237
Ea00238
Ea00239
Ea00240
Ea00241
Ea00242
Ea00243
Ea00244
Ea00245
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
distance between one point and one side of quadrilater-
als is less than 5(mm). Please set coordinates of 4-point
again.
4-Point Fiducial Data Error
Fiducial No.5
6
In quadrilaterals which is composed of 4-point fiducial,
there is interior angle which is over 180 degree. sage.
Please set coordinates of 4-point again.
4-Point Fiducial Data Error
Fiducial No.5
6
It is impossible to use this fiducial number which is se-
lected in this Mount Data, because this data is [4Local-
S]. Please use [4Local-M] Fiducial number of 4-point fi-
ducial.
4-Point Fiducial Data Error
Fiducial No.4
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
PCB DATA ERROR
Mount data No.4
Fiducial data No.6
It is impossible to use this fiducial data, because this data
is [Note]. Please change from [Note] to [Exec].
4-Point Fiducial Data Errorpe Error
Mount data No. 6
Fiducial data No. 2
3
Coordinate of mount point is out of range of 4-point-fidu-
cial. to use this function in Please don't use this 4-point
fiducial for this mount point.
Data Warning
The piece of block that you defined in PCB Information is
different from piece of local badmark.
In this case, machine cannot count Block Numbers in
Production History. If you want to count Block Numbers,
change number of block in PCB Information.
PCB DATA ERROR
No mark data available for the local fiducial. Or the mark
data is not for fiducial.
Mount Data 1
Mark Data 2
PCB DATA WARNING
Height of component is out of range for "Multi Cam".
Component Data 2
It may be impossible to recognize this component by us-
ing "Multi.Cam". It is necessary to check whether this
component is able to be recognized by using "Multi.Cam"
in [ADJUST ASSISTANT]. To continue "Data-Check",
press any key.
MARK DATA WARNING
Templet image can't be downloaded to the vision.
Did you create templet image of target mark?
Don't you make too many mark data in one PCB?
Don't you want to use too many kind of mark?
PCB DATA ERROR
Effective data was not found. There is no data to execute.
Use 'PASS'.
PCB DATA ERROR
There is no mark pattern data. Some pattern matching
function is used for fiducial mark, but it has no pattern
matching data. This data was made by executing of [Ad-
just Assistant] in Mark Information.
PCB DATA ERROR
This component body height is too high. So this compo-
nent is cannot recognize by equipped camera.
Mount Data 10
Component Data 5
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Please set 4 point fiducial data like shown in "Error Message".
Set same number of block in PCB Information as total local badmark
number.
(meaning)The mark data for the specified not an fiducial does not
exist.
(cause)No mark data exists.
(remedy)Create the mark data.
(meaning)It may be impossible to recognized this component by
using "Multi.Cam" because height of this component is out of range
for "Multi.Cam"
(remedy)Please check recognition of this component in [ADJUST
ASSISTANT].
(meaning) No effective data in the PCB data.
(remedy) Use "PASS".
(meaning) There is no data for pattern matching.
(remedy) Make data for pattern matching of fiducial mark in mark
information.
(meaning) This component is too high for its height.
(remedy) Check camera coordinate data.