YAMAHA errer code-a.pdf - 第16页
Ea - 16 ERROR MESSAGES LIST Ea YV88Xabcabcabc Ea00727 Ea00730 Ea00731 Ea00732 Ea00733 Ea00734 Ea00735 Ea00736 Ea00737 Ea00738 Ea00739 Failed to fix the component in fixed component. Alternative component error Failed to …

Ea -15
ERROR MESSAGES LIST
Ea
Ea00691
Ea00692
Ea00693
Ea00700
Ea00701
Ea00702
Ea00703
Ea00704
Ea00705
Ea00706
Ea00707
Ea00710
There is no more than two componet data.
In this condition, this function is not available. You can not
select "REPLACE" or "MULTIPLY COMPONENT" when
Component data is not available.
There is no more than two mount or component data.
In this condition, this function is not available. You can not
select "RENUMBER COMPONENT" tavailable. when
Component data or Mount data is not available.
Not find new Component number All component number
used
Failed to open component information.
Failed to read component information.
Failed to write component information.
Component information are not selected.
There are components on destination whose name is
same as the one shown below. Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component shown below can not be moved because
it doesn't fulfill the condition.
Component 3
Component Name R3216
The condition for moving component
Not using fixed component reference function
Using feeder optimization
The component shown below uses "Teaching" for "Feeder
Position". Would you continue?
Component 3
Component Name R3216
[ESC] key to abort
Other key to continue
The component is multipled.
Would you define as the alternate component?
[ESC] key is not.
Other key is defined.
Failed to open PCB data.
Machine 2
PCB CUK93001
(meaning)The bulk substitution and component separation func-
tions cannot be used because there is no component data.
(cause)No component information exists.
(remedy)Input the component information.
(meaning)The component number control function cannot be used
because there is no data in the component or placing information.
(cause)There is no component or placing information.
(remedy)Input the component or placing information.
(meaning)Editing is not possible because there is not enough space
available for the remaining component data that has to be regis-
tered.
(cause)There is too much component data registered which is not
needed, or there is too much component data which is actually
being used.
(remedy)If too much unnecessary data has been registered, de-
lete some of it. In any other case, the supplementary editing func-
tion cannot be used.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred in the component in formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Component information has not been selected.
(cause)Same as above.
(remedy)Select the component information.
(meaning)When components are being moved in the component
information, a component with the same name already exists at
the destination location.
(cause)A component with the same name is already located at that
destination.
(remedy)If having two components with the same name at the des-
tination is not a problem, go ahead with the shift. Otherwise, press
the ESC key to interrupt the shift.
(meaning)In the group of comp. being moved in the component
information screen, a component exists which uses fixed compo-
nent reference function. The component will not be moved.
(cause)Same as above.
(remedy)No remedy.
(meaning)In the group of components being moved on the compo-
nent information screen, feeder position coordinates exist which
are teaching data.
(cause)Same as above.
(remedy)To cancel the movement because of the position coordi-
nate teaching, press the ESC key. To continue the movement press
any other key.
(meaning)When you execute the multiply component, you select
whether using alternate component or not. This component is al-
ready alternated, this function is not used.
(cause)
(remedy)
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
Ea00711
Ea00712
Ea00713
Ea00715
Ea00720
Ea00721
Ea00722
Ea00723
Ea00724
Ea00725
Ea00726
Failed to read PCB data.
Machine 2
PCB CUK93001
Failed to write PCB data.
Machine 2
PCB CUK93001
Failed to copy PCB data.
Machine 2
PCB CUK93001
Failed to fix the component in PCB.
Machine 2PCB CUK93001
Fixed component information error to open fixed compo-
nent information.
Fixed component information error
Failed to read fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Failed to write fixed component information.
Fixed component information error
Specified fixed component doesn’t exist.
Fixed component information error
“Component Name” are different between PCB data and
fixed component.
Fixed component information error
“Feeder Type” are different between PCB data and fixed
component.
You can’t multiply such a component as
•Using fixed component reference function
•Not using feeder optimization
•Tray components
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)An error occurred when opening the PCB file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. In any other case, check to see how
often the problem occurs, and contact the manufacturer.
(meaning)Fixed components in the PCB data cannot be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Do not attempt to fix the components causing the interfer-
ence, or stop trying to fix the components which are currently dis-
played.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the fixed component in-
formation file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)The specified fixed component information does not ex-
ist.
(cause)There was an error in registering the fixed component refer-
ence number, or the fixed component has not yet been registered.
(remedy)Go back to the editing screen and check the reference
number for the fixed component. If the fixed component has not yet
been registered register it.
(meaning)The component name registered in the PCB data is dif-
ferent from the fixed component being referenced by that compo-
nent.
(cause)Same as above.
(remedy)Change the component name in the PCB data to match
that of the fixed component.
(meaning)The name of the feeder being used in the PCB data is
different from the fixed component feeder being referenced by that
component.
(cause)Same as above.
(remedy)Change the name of the feeder being used in the PCB
data to match that of the fixed component feeder.
(meaning)An attempt was made to input multiple components ref-
erencing fixed components on the component information screen.
(cause)Same as above.
(remedy)There cannot be more than one component referencing
any particular fixed component.

Ea -16
ERROR MESSAGES LIST
Ea
YV88Xabcabcabc
Ea00727
Ea00730
Ea00731
Ea00732
Ea00733
Ea00734
Ea00735
Ea00736
Ea00737
Ea00738
Ea00739
Failed to fix the component in fixed component.
Alternative component error
Failed to read alternative component.
Alternative component error
Loop is not perfect.
Alternative component error
Alternative component specified in the data doesn't ex-
ist.
Machine YV112
Component 3
Alternative component error
"Feeder Type" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"Required Nozzle" is not same as original one.
In Static Components, the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"CountOutStop" is not same as original one.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
"UpdateGroupNo" must be all positive or all 0 in loop.
In Static Components,the component data of same name
are dealed with the alternative component. Each alter-
native components need to same the above condition.
Alternative component error
Mount table is not same as original one.
Alternative component error
You can't use alternative function for tray.
Alternative component error
"Component Name" are different from original one.
(meaning)Components registered in the fixed components cannot
be fixed.
(cause)The components cannot be fixed because they interfere with
another feeder which has already been fixed.
(remedy)Edit the fixed component information and delete the com-
ponent which is causing the interference.
(meaning)An error occurred when reading the alternative compo-
nent data.
(cause)The data for the alternative component specified by the
component data does not exist, or there is a problem with the hard
disk.
(remedy)Go back to the editing screen, and if the alternative com-
ponent does not exist, register it, or change the number of the al-
ternative component.If there is a problem with the hard disk, check
to see how often it occurs, and contact the manufacturer.
(meaning)The settings for alternative components must form a loop
that goes from 1 to 2 to 3 and back to 1 again, but they do not form
this loop.
(cause)The alternative component settings go from 1 to 2 to 3 and
then stop, or form a figure 6 by going from 1 to 2 to 3 and back to 2
again.
(remedy)Go back to the editing screen and check the alternative
component numbers.
(meaning)There is no alternative component data.
(cause)The user has forgotten to register the alternative compo-
nents, or there is a registration error in the alternative component
number.
(remedy)Go back to the editing screen and register the alternative
components, or change the number of the alternative components.
(meaning)The feeder being used for alternative components is not
the same feeder that was used for the original components.
(cause)Same as above.
(remedy)The feeder being used for alternative components must
match the feeder that was used for the original components.
(meaning)The nozzle being used for alternative components is not
the same nozzle that was used for the original components.
(cause)Same as above.
(remedy)Go back to the editing screen and make the nozzle being
used for alternative components match the nozzle that was used
for the original components.
(meaning)The setting for the "count out stop" function used with
alternative components does not match that used with the original
components.
(cause)Same as above.
(remedy)The setting for the "count out stop" function used with al-
ternative components must match that used with the original com-
ponents.
(meaning)In the alternative components loop, all of the settings for
"Use" or "Don't Use" must be set to the same setting.
(cause)In the alternative components loop, some of the compo-
nents reference fixed components, while some do not.
(remedy)Go back to the editing screen and change the settings so
that they all reference fixed components, or none of them do.
(meaning)In the alternative components loop, there are components
with different mounting tables.
(cause)When the settings for the alternative components are 1 -->
2 --> 3, No. 3 is attached to Table B although Nos. 1 and 2 are
attached to Table A, or a different combination of the above.
(remedy)Go back to the editing screen and change the feeder set-
ting numbers so that all of the alternative components are assigned
to the same mounting table.
(meaning)The alternative components cannot be used as tray com-
ponents.
(cause)An attempt was made to use alternative components as
tray components.
(remedy)Go back to the editing screen and change the alternative
component number for the tray components to 0.
(meaning)The name of the alternative component does not match
the name of the original component.
(cause)Same as above.
(remedy)Go back to the editing screen and change the name of
the alternative component so it matches that of the original compo-
nent.
Ea00740
Ea00741
Ea00742
Ea00750
Ea00751
Ea00752
Ea00760
Ea00761
Ea00762
Ea00763
Ea00764
Failed to open fixed component matching work file.
Failed to read fixed component matching work file.
Failed to write fixed component matching work file.
Failed to open fixed component work file.
Failed to read fixed component work file.
Failed to write fixed component work file.
You can't multiply component so many times.
Mount data specifies too big component number.
Selected PCB is not registered in selected line.
Too much point, local and 4-point fiducial data.
Too much mark data.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred in opening the work file for the fixed
component matching
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB dat
a and then delete it. If there is a problem with the disk, check
to see how often the problem occurs, and contact the manufacturer.
(meaning)When component separation is done on the component
information screen, the number of component divisions exceeds
the upper limit.
(cause)An excessively large value was input for the number of com-
ponent divisions
(remedy)Reduce the number of component divisions.
(meaning)The component number specified in the mounting data
exceeds the maximum number of components that the machine
can accommodate.
(cause)The number input for the components in the mounting data
is too large.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(remedy)Go back to the editing screen and correct the component
number in the mounting data.
(meaning)The selected PCB data has not been registered on the
selected line.
(cause)There is an error in the selection of either the line or the
PCB data, or the PCB data has not been registered.
(remedy)Correct the selection of either the line or the PCB data, or
register the PCB data
(meaning)There are too many elements of point, local or 4-point
fiducial data.
(cause)Too many point, local or 4-point fiducials are being used.
(remedy)Reduce the number of point, local or 4-point fiducials.
(meaning)There are too many elements of mark data.
(cause)There are too many elements of mark data being used for
fiducials and bad marks.
(remedy)Reduce the mark data.

Ea -17
ERROR MESSAGES LIST
Ea
Ea00765
Ea00766
Ea00767
Ea00770
Ea00771
Ea00772
Ea00780
Ea00781
Ea00782
Ea00790
Ea00792
Ea00794
Illegal mark number is specified in fiducial data.
Have you saved component information?
[ESC] key to abort fixed comp. match
Other key to exec fixed comp. match
Have you saved component information?
[ESC] key to abort auto distribution
Other key to exec auto distribution
Failed to open nozzle combination information.
Machine 2
Failed to read nozzle combination information.
Machine 2
Failed to write nozzle combination information.
Machine 2
Failed to read machine configuration.
Machine 2
Failed to read machine data.
Machine 2
Failed to read machine specification.
Machine 2
Now copying PCB data to work data
(DUMMY_GENERATOR).
Generating nozzle file.
Accessing disk.
Wait a few moment.
(meaning)The number of the mark specified in the fiducial data.
(cause)Same as above.
(remedy)Go back to the editing screen and correct the mark num-
ber in the fiducial data.
(meaning)Before fixed component matching is carried out on the
component information screen, the component information must
first be saved. This is a confirmation message asking if the informa-
tion has been saved, and not an error message.
(cause)None
(remedy)If the data has not been saved, press the ESC key. After
the data has been saved, try the fixed component matching. If the
data has already been saved, press any other key to proceed.
(meaning)Before fixed component matching is carried out on the
component information screen, the component information must
first be saved. This is a confirmation message asking if the informa-
tion has been saved, and not an error message.
(cause)None
(remedy)If the data has not been saved, press the ESC key. After
the data has been saved, try the fixed component matching. If the
data has already been saved, press any other key to proceed.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when opening the nozzle settings file.
(cause)There is no space available on the hard disk, or there is a
problem with the hard disk.
(remedy)If there is no space available, back up any unnecessary
PCB data and then delete it. If there is a problem with the disk,
check to see how often the problem occurs, and contact the manu-
facturer.
(meaning)An error occurred when reading the machine configura-
tion file.
(cause)The software versions do not match, or there is a problem
with the hard disk.
(remedy)Check the software versions, and contact the manufac-
turer.
(meaning)An error occurred when reading the machine data.
(cause)No machine data has been registered; machine data has
been registered which is different from the registered model num-
ber; or there is a problem with the hard disk.
(remedy)Check to see if the machine data has been registered
correctly. If the problem occurs even if the data has been regis-
tered, check to see how often it occurs, and contact the manufac-
turer.
(meaning)An error occurred when reading the machine specifica-
tions.
(cause)The software versions do not match, or there is a problem
with the hard disk.
(remedy)Check the software versions, and contact the manufac-
turer.
(meaning)The PCB data is being copied as work data for creating
data. This is not an error message.
(cause)None
(remedy)Wait for the process to be completed.
(meaning)The nozzle file is being created. This is not an error mes-
sage.
(cause)None
(remedy)Wait for the process to be completed.
(meaning)The disk is being accessed. This is not an error mes-
sage.
(cause)None
(remedy)Wait for the process to be completed.
Ea00796
Ea00797
Ea00801
Ea00802
Ea00802/
BASEa0
Ea00802/
APL=0
Ea00803
Ea00804
Ea00805
Ea00806
Ea00807
Ea00808
Ea00809
Ea00810
Fail to make work data (DUMMY_GENERATOR).
Using the different make data of PCB Information between
the machines.
PCB name and line name were not chosen.
If both of them are not chosen, you can't make data. If
you want to make data, choose again.
QUICK STOP ACTIVE: "NJ06 FRONT-RIGHT COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the front-right cover is cor-
rectly closed.
QUICK STOP ACTIVE: "NJ07 A TABLE, Y AXIS COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the A table, Y Axis cover is
correctly closed.
QUICK STOP ACTIVE: "NJ07 FRONT-FEEDER SEN-
SOR 2"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the front feeders are in-
serted correctly.
QUICK STOP ACTIVE: "NJ07 FRONT-FEEDER SEN-
SOR 2"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the front feeders are in-
serted correctly.
QUICK STOP ACTIVE: "NJ10 FRONT-FEEDER SEN-
SOR"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the feeders are inserted
correctly into the front feeder plate.
If the feeder exchange system is used, also ensure that
the system is fixed properly.
QUICK STOP ACTIVE: "NM06 REAR-RIGHT COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the rear-right cover is cor-
rectly closed.
QUICK STOP ACTIVE: "NM07 B TABLE Y AXIS COVER"
QUICK STOP FUNCTION for safety is now active. To
continue, please assure that the B table, Y Axis cover is
correctly closed.
QUICK STOP ACTIVE: "NM09 AIR PRESSURE SW",
QUICK STOP FUNCTION for safety is now active. To
continue, please check the supplied air pressure.
QUICK STOP ACTIVE: "NM10 FRONT-FEEDER SEN-
SOR"
QUICK STOP FUNCTION is now active.
To continue, please ensure that the feeders are inserted
correctly into the rear feeder plate.
If the feeder exchange system is used, also ensure that
the system is fixed properly.
QUICK STOP ACTIVE:
"NM13 PCB TRANSFER HOOK LOAD"
QUICK STOP FUNCTION for safety is now active.
Remove the PCB and check the conveyor condition.
QUICK STOP ACTIVE: "NJ11 INTERLOCK ERROR"
QUICK STOP FUNCTION for safety is now active.
Remove the cause of QUICK STOPPING.
QUICK STOP ACTIVE: "NM11 INTERLOCK ERROR"
QUICK STOP FUNCTION for safety is now active.
Remove the cause of QUICK STOPPING.
(meaning)Fail to make the DUMMY_GENERATOR.
(cause)In PCB Inf., difference mark number is used between the
machines.
(remedy)Using the same mark number in PCB Inf. among the ma-
chines.
(meaning)You didn't choose PCB and line name.
(cause)exiting without choice.
(remedy)If you haven't chosen, Choose. If you stop making data, no
need.
(meaning)An emergency stop has occurred because the front cover
of Table A is open, and the interlock has been activated.
(cause)The cover on the front side is open, or the sensor is defec-
tive.
(remedy)Close the cover.
(meaning)The interlock has been activated because the external
axis cover of Table A is open.
(cause)The cover on the front side is open, or the sensor is defec-
tive.
(remedy)Close the cover.
(meaning) Interlock has been activated because outer cover is open
on A table.
(cause) Cover is open or sensor is defective.
(remedy) Close cover.
(meaning) Interlock has been activated because outer cover is open
on A table.
(cause) Cover is open or sensor is defective.
(remedy) Close cover.
(meaning) Sensor that detects front-side feeders which are not firmly
seated has detected loose feeder.
(cause) Feeder has not been installed correctly, or sensor is defec-
tive. In some cases, this message is displayed during an emergency
stop, but this is normal and does not indicate a problem.
(remedy) In any case other than an emergency stop, check feeder
installation.
(meaning)The rear cover of Table B is open.
(cause)A cover is open, or the sensor is defective.
(remedy)Close the cover.
(meaning)The interlock has been activated because the front axis
cover of Table B is open.
(cause)A cover is open, or the sensor is defective.
(remedy)Close the cover.
(meaning) Sensor that detects rear-side feeders which are not firmly
seated has detected loose feeder.
(cause) Feeder has not been installed correctly, or sensor is defec-
tive. In some cases, this message is displayed during an emergency
stop, but this is normal and does not indicate a problem.
(remedy) In any case other than an emergency stop, check feeder
installation.
(meaning)The load on the PCB transport unit is excessive, and the
interlock has been activated.
(cause) The edge of a PCB has gotten caught on the edge of the
connecting section of the conveyor, or an excessive load is placed
on the transport unit because the PCB is too wide for the conveyor,
thus activating the interlock.
(remedy)Find out where the excessive load is occurring, and adjust
the PCB width or the conveyor position.
(meaning) The interlock of the quick-stop function connected to NJ11
has been detected, and the emergency stop function has been ac-
tivated.
(cause) This depends on optional equipment being used.
(remedy) This depends on optional equipment being used.
(meaning) The interlock of the quick-stop function connected to
NM11 has been detected, and the emergency stop function has
been activated.
(cause) This depends on optional equipment being used.
(remedy) This depends on optional equipment being used.