(E12001 Cause and Solution)There may be a mechanical problem
with the vertical movement of the squeegee, or the Squeegee Lower
Limit sensor may be malfunctioning or defective.
Check the sensor input on the Squeegee screen.
(E12002 Cause and Solution)The following are possible causes:
(1)No squeegee has been set.
(2)The mask has not been set properly.
(3)The approach distance in the PCB data has been set larger than
the conveyor plate width, so print force control is being carried out
away from the PCB plate.
If the error still occurs after correcting the above, there may be a
hardware problem with the I/O board or load cell.
(E13000 Cause and Solution)There may be a mechanical problem
with the vertical movement of the main stopper, or the Main Stop-
per Upper Limit sensor may be malfunctioning or defective.
Check the sensor input status on the Conveyor screen.
(E13001 Cause and Solution)There may be a mechanical problem
with the vertical movement of the main stopper, or the Main Stop-
per Upper Limit sensor may be malfunctioning or defective.
Check the sensor input status on the Conveyor screen.
(E13002 Cause and Solution)There may be a mechanical problem
with the vertical movement of the PCB flap, or the Flap Front Oper-
ate, Flap Front Cancel, Flap Back Operate, or Flap Back Can-
cel sensor may be malfunctioning or defective. Check the sensor
input status on the Conveyor screen.
(E13003 Cause and Solution)There may be a mechanical problem
with the vertical movement of the PCB flap, or the Flap Front Oper-
ate, Flap Front Cancel, Flap Back Operate, or Flap Back Can-
cel sensor may be malfunctioning or defective. Check the sensor
input status on the Conveyor screen.
(E13004 Cause and Solution)There may be a mechanical problem
with the movement of the edge clamp, or the Edge Clamp sensor
may be malfunctioning or defective. Check the sensor input status
on the Conveyor screen.
(E13005 Cause and Solution)There may be a mechanical problem
with the movement of the edge clamp, or the Edge Clamp sensor
may be malfunctioning or defective. Check the sensor input status
on the Conveyor screen.
(E13006 Cause and Solution)There may be a mechanical problem
with the vertical movement of the PCB press, or the PCB Press
Upper Limit sensor may be malfunctioning or defective. Check the
sensor input status on the Conveyor screen.
(E13007 Cause and Solution)There may be a mechanical problem
with the vertical movement of the PCB press, or the PCB Press
Lower Limit sensor may be malfunctioning or defective. Check the
sensor input status on the Conveyor screen.
(E13008 Cause and Solution)The PCB has not been picked up cor-
rectly, it is too warped, or the vacuum sensor has not been correctly
adjusted.
If the vacuum sensor cannot be adjusted correctly, air may be leak-
ing from the PCB pickup path, or the vacuum sensor may be mal-
functioning or defective.
SQUEEGEE DOWN ERROR
Failed to move squeegee down.
PRINT FORCE CONTROLL ERROR
Fail to control Print Force.
SOLDER AMOUNT ERROR
Enclosed head is lack of Solder.
Please suply solder.
Before supply, please press "PCB Stop" button on Select
PCB window to continue printing for the PCB already
carried in and carry it out.
If you want to supply solder immediately with reset,please
do not forget to remove the PCB already carried in.
SQUEEGEE TYPE ERROR
"Enclosed Head" is selected for "Squeegee Type" param-
eter in PCB data.
SQUEEGEE TYPE ERROR
"Double" is selected for "Squeegee Type" parameter in
PCB data. But Double Squeegee is not attached correctly.
SQUEEGEE TYPE ERROR
"Enclosed Head" is selected for "Squeegee Type" param-
eter in PCB data. But Enclosed head is not attached cor-
rectly.
MAIN STOPPER UP ERROR
Failed to move main stopper up.
MAIN STOPPER DOWN ERROR
Failed to move main stopper down.
PCB FLAP UP ERROR
Failed to move PCB flap up.
PCB FLAP DOWN ERROR
Failed to move PCB flap down.
EDGE CLAMP FIX ERROR
Failed to move edge clamp for fixation.
EDGE CLAMP RELEASE ERROR
Failed to move edge clamp for release.
PCB PRESS UP ERROR
Failed to move PCB press up.
PCB PRESS DOWN ERROR
Failed to move PCB press down.
PCB VACUUM CHECK ERROR
The result of PCB vacuum check was NG.
It is possible that PCB is not fixed on the conveyor or
PCB is warped too much or adjustment of the vacuum
sensor is not good.
Ea14000
Ea14001
Ea14002
Ea14003
Ea14004
Ea14005
Ea14006
Ea14007
(E14000 Cause and Solution)PCBs cannot be loaded under the
following conditions.
(1) The Entrance sensor has not been triggered.
(2) The PCB Fixing Position sensor has been triggered.
(3) The Exit sensor has been triggered.
Check to see if the PCB has been corrected loaded onto the con-
veyor, and check for PCBs at the work position and exit. Then try
again.
Check the sensor input status on the Conveyor screen.
If the error occurs even though the PCB has been correctly loaded
and there are no other PCBs on the conveyor, the Entrance, PCB
Fixing Position, or Exit sensor may be malfunctioning or defec-
tive.
(E14001 Cause and Solution)PCBs cannot be unloaded under the
following conditions.
(1) The Entrance sensor has been triggered.
(2) The PCB Fixing Position sensor has not been triggered.
(3) The Exit sensor has been triggered.
Check to see if the PCB is at the PCB fixing position, and check for
PCBs at the entrance and exit. Then try again.
Check the sensor input status on the Conveyor screen.
If the error occurs even though the PCB is at the fixing position and
there are no other PCBs on the conveyor, the Entrance, PCB
Fixing Position, or Exit sensor may be malfunctioning or defec-
tive.
(E14002 Cause and Solution)The PCB cannot be secured if the
PCB Fixing Position sensor has not been triggered.
Make sure the PCB to be secured is at the appropriate position,
and try again.
Check the sensor input status on the Conveyor screen.
If the error occurs even though the PCB is at the appropriate posi-
tion and there are no other PCBs on the conveyor, the Entrance,
PCB Fixing Position, or Exit sensor may be malfunctioning or
defective.
(E14003 Cause and Solution)The PCB was not transported from
the entrance to the fixing position in a given period of time.
The following are possible causes:
(1)The conveyor width is not correct.
(2)The conveyor speed has not been correctly adjusted.
(3)The conveyor belt is defective.
(4)The conveyor motor is defective.
(5)The Entrance or PCB Fixing Position sensor is malfunction-
ing or defective. If the conveyor width is not correct, see if the cor-
rect value has been entered for PCB Size Y on the PCB screen.
Check the sensor input value on the Conveyor screen.
(E14004 Cause and Solution)The PCB was not transported from
the fixing position to the entrance or exit in a given period of time.
The following are possible causes:
(1)The conveyor width is not correct.
(2)The conveyor speed has not been correctly adjusted.
(3)The conveyor belt is defective.
(4)The conveyor motor is defective.
(5)The Entrance, PCB Fixing Position or Exit sensor is mal-
functioning or defective. If the conveyor width is not correct, see if
the correct value has been entered for PCB Size Y on the PCB
screen.
Check the sensor input value on the Conveyor screen.
(E14005 Cause and Solution)If the conveyor width has not changed
correctly, automatic operation cannot be started.
Use the Conveyor Width button on the Conveyor screen to change
the width, and then try again.
ENABLE TO CARRY PCB IN
It is enable to carry PCB in.
Followings are possible as the reason.
(1)There is no PCB at entrance position of the conveyor.
(2)There is PCB at print position of the conveyor.
(3)There is PCB at exit position of the conveyor.
ENABLE TO CARRY PCB OUT
It is enable to carry PCB out.
Followings are possible as the reason.
(1)There is PCB at entrance position of the conveyor.
(2)There is no PCB at print position of the conveyor.
(3)There is PCB at exit position of the conveyor.
ENABLE TO FIX PCB
It is enable to fix PCB.
Followings are possible as the reason.
(1) There is no PCB at print position of the conveyor.
CARRY PCB IN ERROR
Failed to carry PCB in.
CARRY PCB OUT ERROR
Failed to carry PCB out.
CONVEYOR WIDTH ERROR
Conveyor width is different from PCB size Y.
ENABLE TO CARRY PCB OUT
It is enable to move PCB table with a PCB on the con-
veyor.
Please remove the PCB.
FAILED TO FIX PCB
There is no PCB on the fixation position of the conveyor.
Ea -41
ERROR MESSAGES LIST
Ea
Ea15000
Ea15001
Ea15002
Ea15003
Ea15004
Ea15005
Ea15006
Ea15007
(E15000 Cause and Solution)The cleaner cannot be connected to
the PCB table under the following conditions.
(1)The cleaner and PCB table are already connected.
(2)The cleaner has not been secured to the base. Use the Emer-
gency Stop button to turn off the servo, and then use the Cancel
and Connect buttons on the Cleaner screen to secure the cleaner
properly to the base.
If the message Cleaner is not stored. Store cleaner? appears when
operating axes, always press OK to automatically store the cleaner.
If the error still occurs, there may be a mechanical problem with the
cleaner securing pin or connecting pin, or the Cleaner Fixing Up-
per Limit, Cleaner Fixing Lower Limit, Cleaner Connect Upper
Limit or Cleaner Connect Lower Limit sensor may be malfunc-
tioning or defective.
Check the sensor input on the Cleaner screen.
(E15001 Cause and Solution)Cleaning cannot be carried out under
the following conditions.
(1) The cleaner and PCB table are separated.
(2) The cleaner is secured to the base.
(3) The cleaner is not in the lowered position.
Use the Emergency Stop button to turn off the servo, and then use
the Cancel and Connect buttons on the Cleaner screen to se-
cure the cleaner properly to the base.
If the message Cleaner is not stored. Store cleaner? appears when
operating axes, always press OK to automatically store the cleaner.
If the error still occurs, there may be a mechanical problem with the
cleaner securing pin or connecting pin, or the Cleaner Fixing Up-
per Limit, Cleaner Fixing Lower Limit, Cleaner Connect Upper
Limit or Cleaner Connect Lower Limit sensor may be malfunc-
tioning or defective.
Check the sensor input on the Cleaner screen.
(E15002 Cause and Solution)The cleaner and PCB table cannot be
separated under the following conditions.
(1) The cleaner and PCB table are already separated.
(2) The cleaner is secured to the base.
Use the Emergency Stop button to turn off the servo, and then use
the Cancel and Connect buttons on the Cleaner screen to se-
cure the cleaner properly to the base.
If the message Cleaner is not stored. Store cleaner? appears when
operating axes, always press OK to automatically store the cleaner.
If the error still occurs, there may be a mechanical problem with the
cleaner securing pin or connecting pin, or the Cleaner Fixing Up-
per Limit, Cleaner Fixing Lower Limit, Cleaner Connect Upper
Limit or Cleaner Connect Lower Limit sensor may be malfunc-
tioning or defective.
Check the sensor input status on the Cleaner screen.
(E15003 Cause and Solution)A problem occurred when connecting
the cleaner and the PCB table.
There may be a mechanical problem with the cleaner connecting
pin, or the Cleaner Connecting Upper Limit or Cleaner Connect-
ing Lower Limit may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E15004 Cause and Solution)A problem occurred when separating
the cleaner and the PCB table.
There may be a mechanical problem with the cleaner connecting
pin, or the Cleaner Connecting Upper Limit or Cleaner Connect-
ing Lower Limit may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E15005 Cause and Solution)A problem occurred when securing
the cleaner to the base.
There may be a mechanical problem with the cleaner fixing pin, or
the Cleaner Fixing Upper Limit or Cleaner Fixing Lower Limit
may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E15006 Cause and Solution)A problem occurred when separating
the cleaner from the base.
There may be a mechanical problem with the cleaner fixing pin, or
the Cleaner Fixing Upper Limit or Cleaner Fixing Lower Limit
may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E15007 Cause and Solution)There may be a mechanical problem
with the vertical movement of the cleaner, or the Cleaner Upper
Limit sensor may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
ENABLE TO CONNECT CLEANER
It is enable to connect cleaner with PCB table.
Followings are possible as the reason.
(1) Cleaner is already connected with PCB table.
(2) Cleaner is not fixed on the base.
ENABLE TO CLEANING MASK
It is enable to work cleaner.
Followings are possible as the reason.
(1) Cleaner is not connected with PCB table.
(2) Cleaner is fixed on the base.
(3) Cleaner is not in lower position.
ENABLE TO SEPERATE CLEANER
It is enable to separate cleaner with PCB table.
Followings are possible as the reason.
(1) Cleaner is already separated from PCB table.
(2) Cleaner is fixed on the base.
CLEANER CONNECT ERROR
Failed to connect cleaner with PCB table.
CLEANER SEPERATE ERROR
Failed to separate cleaner from PCB table.
CLEANER FIX ERROR
Failed to fix cleaner on the base.
CLEANER RELEASE ERROR
Failed to release cleaner from the base.
CLEANER UP ERROR
Failed to move cleaner up.
Ea15008
Ea15009
Ea15010
Ea15011
Ea15012
Ea16000
Ea16001
Ea16002
Ea16003
Ea16004
Ea16005
Ea16006
Ea17000
Ea17001
Ea17002
Ea17003
Ea17004
Ea17005
Ea17006
CLEANER UP ERROR
Failed to move cleaner down.
GAUZE ROLLING FINISHED
All gauze has been rolled up.
Please exchange gauze roll to new one.
GAUZE ROLLING FINISHED
All gauze has been rolled up.
Please exchange gauze roll to new one.
LACK OF SOLVENT
Cleaner solvent is lack.
Please supply it.
CLEANING INTERVAL END
Specified number of PCB for cleaning interval is finished.
Cleaning will start.
Please remove the PCB on the conveyor.
MASK CAMERA LIGHT UP ERROR
Failed to move mask camera light up.
MASK CAMERA LIGHT UP ERROR
Failed to move mask camera light down.
MASK CLAMP FIX ERROR
Failed to move mask clamp for fixation.
MASK CLAMP RELEASE ERROR
Failed to move mask clamp for release.
MASK CLAMP ERROR
Mask is not clamped.
Please clamp the mask.
ILLEGAL MASK OFFSET
Illegal Mask Offset is specified.
MASK INSPECTION INTERVAL END
Specified number of PCB for mask inspection interval is
finished.
Mask inspection will start.
Please remove the PCB on the conveyor.
IMAGE DATA SAVE ERROR
Failed to save the image data.
IMAGE DATA FILE OPEN ERROR
Failed to open the image data file.
IMAGE DATA FILE WRITE ERROR
Failed to write the image data file.
IMAGE DATA FILE READ ERROR
Failed to read the image data file.
ENABLE TO GET IMAGE DATA
Failed to get the image data.
PCB FIDUCIAL DETECTION ERROR
Failed to detect defined mark.
Mark %d
Mark No. %d
MASK FIDUCIAL DETECTION ERROR
Failed to detect defined mark.
Mark %d
Mark No. %d
(E15008 Cause and Solution)There may be a mechanical problem
with the vertical movement of the cleaner, or the Cleaner Upper
Limit sensor may be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E15009 Cause and Solution)The winding detection sensor does
not go on when the cleaner gauze roll is turned.
The gauze roll may have been completely wound, or has not been
set correctly, or the Winding sensor may be malfunctioning or de-
fective.
Check the sensor input status on the Cleaner screen.
(E15010 Cause and Solution)The winding detection sensor does
not go off when the cleaner gauze roll is turned.
The gauze roll may have been completely wound, or has not been
set correctly, or the Winding sensor may be malfunctioning or de-
fective.
Check the sensor input status on the Cleaner screen.
(E15011 Cause and Solution)Replenish the cleaner solvent.
If this error occurs even though there is sufficient solvent, or the
solvent has been replenished, the Remaining Solvent sensor may
be malfunctioning or defective.
Check the sensor input status on the Cleaner screen.
(E16000 Cause and Solution)There may be a mechanical problem
with the vertical movement of the mask camera light, or the Mask
Camera Light Upper Limit or Mask Camera Light Lower Limit sen-
sor may be malfunctioning or defective.
Check the sensor input on the Mask screen.
(E16001 Cause and Solution)There may be a mechanical problem
with the vertical movement of the mask camera light, or the Mask
Camera Light Upper Limit or Mask Camera Light Lower Limit sen-
sor may be malfunctioning or defective.
Check the sensor input on the Mask screen.
(E16002 Cause and Solution)There may be a mechanical problem
with the mask clamp, or the Clamp Check sensor may be malfunc-
tioning or defective.
Check the sensor input on the Mask screen.
(E16003 Cause and Solution)There may be a mechanical problem
with the mask clamp, or the Clamp Check sensor may be malfunc-
tioning or defective.
Check the sensor input on the Mask screen.
(E16004 Cause and Solution)If the mask has not been clamped,
automatic operation cannot be started.
Use the Mask Clamp button on the Mask screen to clamp the
mask, and then try again.
(E17000 Cause and Solution)Check the file name and then try again.
(E17001 Cause and Solution)Check the file name and then try again.
(E17002 Cause and Solution)Check the file name and then try again.
(E17003 Cause and Solution)Check the file name and then try again.
(E17004 Cause and Solution)There may be a hardware defect in
the vision board.
Ea -42
ERROR MESSAGES LIST
Ea
Ea17007
Ea17008
Ea17009
Ea17010
Ea17011
Ea17012
Ea17013
Ea17014
Ea18000
Ea19000
Ea19001
Ea19002
Ea19003
Ea19004
Ea19005
Ea19006
PCB FIDUCIAL AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of tol-
erance.
Mark %d
Mark No. %d
MASK FIDUCIAL AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of tol-
erance.
Mark %d
Mark No. %d
PCB FIDUCIAL DETECTION ERROR
A part of the fiducial mark is located out of the specified
search area or the fiducial correction angle is too large.
Mark %d
Mark No. %d
MASK FIDUCIAL DETECTION ERROR
A part of the fiducial mark is located out of the specified
search area or the fiducial correction angle is too large.
Mark %d
Mark No. %d
PCB FIDUCIAL SHAPE ERROR
Failed to detect a fiducial mark of the specified shape.
Mark %d
Mark No. %d
MASK FIDUCIAL SHAPE ERROR
Failed to detect a fiducial mark of the specified shape.
Mark %d
Mark No. %d
PCB FIDUCIAL AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of tol-
erance (Special).
Mark %d
Mark No. %d
MASK FIDUCIAL AREA OR PERIMETER ERROR
The detected fiducial mark area or perimeter is out of tol-
erance (Special).
Mark %d
Mark No. %d
ENABLE TO CREATE BACK GROUND TASK
Failed to create background task.
Please re-boot your machine.
SOLDER SUPPLY INTERVAL END
Specified number of PCB for solder supply interval is fin-
ished.
Please supply solder on the mask.
If you supply it on another side of the mask, please change
squeegee direction.
ROT END
Specified number of PCB is finished.
MANUAL CLEANING INTERVAL END
Specified number of PCB have already printed.
Please clean the mask manually.
Before work please reset auto running and press
"MANUAL CLEANING" button in CLEANER window.
When you press the button, the squeegee and PCB table
moves to escape position.
MANUAL MASK INSPECTION INTERVAL END
Specified number of PCB have already printed.
Please close error message and execute mask inspec-
tion manually.
After cleaning please restart production.
PCB STOP
Specified is finished.
PCB INSPECTION INTERVAL END
Specified number of PCB have already printed.
Please close error message and execute mask inspec-
tion through the camera.
After cleaning please restart production.
PCB INSPECTION INTERVAL END
Specified number of PCB have already printed.
Please close error message and execute mask inspec-
tion manually.
After cleaning please restart production.
(E18000 Cause and Solution)Restart the machine.
If the error still occurs, re-install the YVP Application Disk.
Ea20000