7OM-1625-004_w.pdf - 第116页

7OM-1603 Chapter 3 : 2. Menus for System Setting 3-17 1003-002 [2] X (Horizontal) and Y (V ertical) [mm] These offset parameters are used to adjust the positional deviation based on the design dimensions representing the…

100%1 / 187
7OM-1603
3-16
Chapter 3 : 2. Menus for System Setting
1003-002
2.1.1 "Feeder B" Window
[1]
[2] [3]
[5]
[4]
[6]
F7C16
Feeder Offset B
This offset data is used to correct variation in the feeder.
·
The X and
Y parameters are recognition-processed during the automatic
operation to track the positional relation between the nozzle and component
centers and updated automatically for better pickup posture (pickup on the
component center).
Note: In normal cases, it is not necessary to enter any parameters.
·
The "L [mm]" parameters are not updated automatically but the entered ones
are reected.
Feeder offset parameters are added to actual offset values.
Actual Offset Values = Feeder (A) Offset + Feeder (B) Offset
[1] Feeder Change Tab
Another tab sheet can be opened by pressing the corresponding "Feeder
Base" tab.
Graphic
Development
7OM-1603
Chapter 3 : 2. Menus for System Setting
3-171003-002
[2] X (Horizontal) and Y (Vertical) [mm]
These offset parameters are used to adjust the positional deviation based on
the design dimensions representing the component pickup position for each
individual feeder slot Nos. (Fdr Nos.).
F211
F111
Rear Feeder
Front Feeder
Front Side of Machine
Y(+)
X(+)
Pickup Position
Pickup Position
Direction of Tape FeedDirection of Tape Feed
F7C17
[3] L (Height) [mm]
Pickup Reference Level
Nozzle
L(+)
F7C18
When a value is entered with a plus (+) sign, the pickup height is reected on
the direction in which the descending stroke of the nozzle will increase.
[4] [Blk Select] button
In this section, the installed multi-layer tray feeder block can be selected.
7OM-1603
3-18
Chapter 3 : 2. Menus for System Setting
[5] [Ret] button
When this button is Pressed, the "Offset Data" window
[6] [Save] button
When this button is pressed, the input data is applied.
[Cancel] button
When this button is pressed, the input data is cancelled and the save data is
returned.
0908-001