Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
26
7.4 ASM Traceability Version 5.4 SP1
Software version 5.4 SP1 of ASM Traceability supports the SIPLACE X-series, X-series S,
SX-series, DX-series, CA-series and TX-series placement machines.
Compatible mode: SIPLACE Traceability 4.x
NOTICE
A detailed description can be found in the "Traceability User Guide".
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
27
8 Restrictions
For details concerning possible machine configurations, please consult the latest version of the
machine specification.
Restrictions to features in previous versions can be found in the Station Software V7xx Feature
Description, item no. [00197741-xx].
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
28
9 Corrected Errors
711.1 Station Software
The 711.1 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-146654832 During the reference run, it was detected that a nozzle was missing at the
placement head. At the Production and Advanced Production activity levels
there were no options to solve the problem.
D17880-70533 During the verification with the C&P20 P placement head, the software hung
up and no log could be created.
Table 9-1: Corrected errors station software version 711.1
711.0 Station Software
The 711.0 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-135745045 If the operator enabled the air pressure valve in the Manual Operations, the
head air valve was automatically enabled too after a short time. Thereafter,
subsequent error at the station.
D1-135900901 Dual conveyor could not be changed to single conveyor mode.
D1-136250501
D1-136413701
D1-136288601
D1-137645501
D1-143628901
The board was loaded into the input section and remained there.
D1-136860201 Message after job specification that the conveyor setting was incorrect
although it was correct.
D1-138356338 Temperature sensor gantry 3: 30716 Temperature sensor is
deactivated
.
D1-139665150
eSW: sporadic problem with the motor synchronization of the lifting table after
a correction in the placement area.
eSW: sporadisches Problem mit der Motorsynchronisierung (Hubtisch mit
Bandmotor) nach einer Korrektur im Bestückbereich (Leiterplatte fährt zurück
und Lasersensor wird erneut angefahren).
D1-140600201 After station software 710 had been uninstalled, Windows did not boot.
D1-140653201 The station software stopped unexpectedly.