00198500-02_VD_711.1_R18-1_DE_EN.pdf - 第28页

Station Software 71 1.1 (R18 - 1) / Versio n Description 05/2018 Edition 28 9 Corrected Error s 711.1 Station Software The 711.1 station software version contains all er ror corrections of the previous 7xx versions. Addi…

100%1 / 82
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
27
8 Restrictions
For details concerning possible machine configurations, please consult the latest version of the
machine specification.
Restrictions to features in previous versions can be found in the Station Software V7xx Feature
Description, item no. [00197741-xx].
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
28
9 Corrected Errors
711.1 Station Software
The 711.1 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-146654832 During the reference run, it was detected that a nozzle was missing at the
placement head. At the Production and Advanced Production activity levels
there were no options to solve the problem.
D17880-70533 During the verification with the C&P20 P placement head, the software hung
up and no log could be created.
Table 9-1: Corrected errors station software version 711.1
711.0 Station Software
The 711.0 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-135745045 If the operator enabled the air pressure valve in the Manual Operations, the
head air valve was automatically enabled too after a short time. Thereafter,
subsequent error at the station.
D1-135900901 Dual conveyor could not be changed to single conveyor mode.
D1-136250501
D1-136413701
D1-136288601
D1-137645501
D1-143628901
The board was loaded into the input section and remained there.
D1-136860201 Message after job specification that the conveyor setting was incorrect
although it was correct.
D1-138356338 Temperature sensor gantry 3: 30716 Temperature sensor is
deactivated
.
D1-139665150
eSW: sporadic problem with the motor synchronization of the lifting table after
a correction in the placement area.
eSW: sporadisches Problem mit der Motorsynchronisierung (Hubtisch mit
Bandmotor) nach einer Korrektur im Bestückbereich (Leiterplatte fährt zurück
und Lasersensor wird erneut angefahren).
D1-140600201 After station software 710 had been uninstalled, Windows did not boot.
D1-140653201 The station software stopped unexpectedly.
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
29
D1-140734101 Head cycle counts in the SIPLACE Pro optimized results and in the actual
machine run did not match each other.
D1-140943701 The images for the feeder pickup position were not put together correctly..
D1-141418801 Conveyor sub-system 1: 30450 Unspecified hardware error.
D1-142534201 Board barcodes had to be programmed with 2 mm offset on an SX V2
placement machine. The original data did not work.
D1-144465801 Endurance run functions could not be selected in the Manual Operations; an
error message was displayed immediately.
D18275-3701 TX2i placement machine: Machine stopped during normal production without
any error message.
Table 9-2: Corrected errors station software version 711.0
710.1 SP1
Error No.
Error description
D1-141115401
eSW: a board in the input conveyor was not transported into the placement
area.
D1-145118902 Production did not start after confirming nozzle configuration.
D1-145571745
D1-147043656
D1-145527801
eSW: the z axis was not able to initialize during the reference run; the
following error handling let the segment drop out of the raceway.
D1-146272909
After a restart the language was set to English although it was German
before.
D1-146361597 The "feed forward" button was not active.
D1-146433623
LED Centering: the machine omitted the validation of the glass plate before
placing the led on it.
D1-146449111
D1-146429348
The automatic calibration of the Vacuum Tooling failed because of incorrect
positions for chuck fiducials.
D1-146494912
SIPLACE ProgressData event "ProductionProgress" delivered wrong Context-
ID (CtxId).
D1-146524401
After program download a board was placed although one pin was declared
as faulty.
D1-146590633
eSW: there was a transport error when a special carrier was used because
the board sensor in the output section was activated too early.
D1-146802617
eSW: If the upstream machine was stopped and the conveyor software tried
to exchange a board in processing area 1, the board in the input area could
not be moved until the upstream machine was started.
D1-146821856 Conveyor: the width adjustment could not adjust the maximum width.
D1-146933102
D1-146935404
When BETZ feeders were used, there were more pickup errors with segment
1 (CPP head) than with the other segments.
D1-147134301 Gantry 2 stopped over the WPC6 tray without error message.
D1-147150443 The "automatic check of nozzle changer" function did not work.
D1-147177501 710.1.HF6: the tape cutter info was missing in the maintenance menu.
D1-147189601
A tray could be loaded into WPC although the station recognized it as too
high later.