00198500-02_VD_711.1_R18-1_DE_EN.pdf - 第34页
Station Software 71 1.1 (R18 - 1) / Versio n Description 05/2018 Edition 34 71 0.1 Patch 2 Error no. Error description D1 - 139125591 At a TX machine , an er ror message was displayed t hat the weight dependent motor cur…

Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
33
D1-144666909
Automatic pin recognition with 8mm feeder: OIS erroneously was counting a
reject.
D1-144698005
A component was marked for teaching before placement. When the new
position was saved the software hung up.
D1-144711401 The thresholds were not recalculated when the recipe was changed.
D1-144728801 The station software hung up after a mechanical change of the conveyor.
D1-144830807 The nozzle could not be returned if there was still a component on the nozzle.
D1-144854701
eSW: the motor for the width adjustment could not be calibrated (SX 1/2 with
single conveyor).
D1-144860701
Error message 34036 Y axis mapping data not activated when Y
mapping was executed and the mapping data should be restored.
D1-144868153
The station software stopped during/after placement with error message
30016 Unhandled exception error
.
D1-144890453
Dirty glue feeder lead to error message 34432 Fatal error, maximum
number of retries reached
.
D1-145008101 Error message:
34641 Cannot reject nozzle
.
D1-145043932
When a gantry did no longer travel over the current board, because high
components were placed by the head of the other gantry, the inapprehensible
message 32539 Beware of collision with high components on
board
was displayed.
D1-145070937 The DUMP archive was not deleted after an auto bug report.
D1-145384201 Unexpected software malfunction - the application had to be closed.
D17845-17170
When we taught and accepted the placement position, the teach offset
x/y/angle in the placement list changed automatically even though we did not
change it.
D17933-41707
The CPP head moved continuously left and right without picking up the
component on the waffle pack of the WPC6.
D18093-21501 The software hung up with the error message that ISS did not respond.
D18093-22703
Sporadically the station SW stopped during placement with the error
messages 30016 Unhandled exception error and 32602 The
software has stopped unexpectedly
.
D18093-22757 Error message
34488 Placement head is unable to continue
.
D18170-42001 There were inconsistent nozzle scan results and misleading error messages.
D18364-1423
The production stopped without any error message after having recognized
the fiducials.
D18400-101
Gantry1 stopped with message 32535 Checking nozzle
configuration: C&P20 P Head
.
D18403-209 eSW: The X-axis motor hit the buffer mount of the X-axis.
Table 9-6: Corrected errors station software version 710.1 Patch 4

Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
34
710.1 Patch 2
Error no. Error description
D1-139125591 At a TX machine, an error message was displayed that the weight dependent
motor current was too big.
D1-140020401 There was an unhandled exception when a tray was used on a carrier.
D1-140048801 The reject bin configuration was not displayed correctly on the GUI.
D1-141199449 The station software stopped during / after placement with error message
30016 Unhandled exception error
.
D1-141376801 When the embedded Software was updated, error message 30554
Subsystem is not responding (dp axis)
was displayed.
D1-141376849 The state of the board was displayed even if the board had reached the output
conveyor.
D1-141386801 The component sensor data was invalid and could not be restored.
D1-141541301 Status 30622 Nozzle missing was not reset for the nozzle.
D1-141564601 Coplan-MCT was not possible: instead of using the SST33 camera the SST25
was used. With this camera the calibration failed.
D1-141619501 After a machine restart, the message 30450 WPC2 unspecified
hardware error
was displayed.
D1-141670801
D1-141138729
D1-142037601
eSW: After restarting the machine, the message 30555 Subsystem is
not activated (main distributor) was displayed sporadically, but
machine worked without any problems.
D1-141993601 The button to change the acceleration of JTF-ML2 was missing.
D1-142003201 The Edit pickup point function should get a separate user level.
D1-142176533 The machine stopped during production.
D1-142207343 It was not possible to change the filling level of the JTF.
D1-142229001 During the shutdown of the machine, error message unhandled exception
error
was displayed.
D1-142248701 C&P20 M2 segments were not recognized.
D1-142266401 Along with the "LBO 1500" option, support pins could not be set.
D1-142276101 eSW: TX micron with station software 710.1: Along with vacuum tooling there
was always an error with the lifting table motors during board loading.
D1-142283901 Several problems with vacuum tooling with station software 710.1.
D1-142290001 Error message 30977 Timeout acquiring resources was displayed
and the board disappeared on the GUI.
D1-142328345
D1-142328387
D1-142328735
Teaching the pickup position during production resulted in a software hang-up.
D1-142441301
D1-142325401
eSW: The x-axis parametrization could not be executed any longer.

Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
35
D1-142505101 The software hung up and had to be restarted.
D1-142515201 CA4: When the mapping ACT was performed, the fiducials were measured
only with the master gantry. There was no dual gantry transformation.
D1-142536004 The station software hung up when the user level was changed.
D1-142624049 When a carrier X was set up, the station reported feeder missing;
pickup not possible
.
D1-142673101 The Skip recognition button was active on the basic production level. The
activity level could be changed now.
D17915-12902 The first component was not picked up after feeder error.
D18317-2201 The machine stopped during production without any error message.
D18164-10301 Omitted tracks were reset when the setup was changed, but not when the
same job was downloaded again. A job download should also activate the
track.
Table 9-7: Corrected errors station software version 710.1 Patch 2
710.1 Patch 1
Error no. Error description
D1-130023341 The measurement of cycle time did not work for some configurations.
D1-140150945 Confirming the exchange of a cassette did not set the levels full.
D1-140532401 LED-Centering: the glass plate was worn out too fast.
D1-140754501 After a reboot after a virus scan, the software did not start any longer.
D1-140811309 After a partial download, all feeder LEDs were on until the table was taken out
and in again.
D1-141145401 It was not possible to download an accuracy of 25µm for SST45.
D17754-11401 Gantry 2 waited for gantry 3 several cycles before it started to place.
D18224-30501 A board in lane 2 was placed only when lane 1 got empty. The reason was a
safety distance which is needed when a high component is placed on the side
of the CPP gantry. This distance value was slightly too high.
Table 9-8: Corrected errors station software version 710.1 Patch 1