00198500-02_VD_711.1_R18-1_DE_EN.pdf - 第32页

Station Software 71 1.1 (R18 - 1) / Versio n Description 05/2018 Edition 32 D1 - 141676541 The gripper got lost and the machine r eported 30482 Z axis is bey ond maximum position, position is in empty space, segment: 2 b…

100%1 / 82
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
31
710.1 Patch 5
Error No.
Error description
D1-140785106
eSW: boards without board barcode required manual confirmation when they
were transported into the next machine.
D1-142933001
eSW: PCB-A interface: the board did not drive into the machine when the
acceleration was too small (< 1400 mm/s²).
D1-143801301
When the acceleration values were taught at the station, the x-axis values
were not transferred.
D1-145171201 Although the panel was marked with an ink spot, it got assembled.
D1-145202821 Restoring the conveyor configuration after mapping did not work.
D1-145232501 The software hung up after having sent a job.
D1-145282601
When conveyor lane 2 was calibrated, the conveyor control stopped with error
message
ISS software is not responding
.
D1-145398946
eSW: although there was no board in the output area, the machine displayed
one and could not continue production.
D1-145422501
eSW: the board moved directly from PA2 to the next machine; it did not stop
in the output area if the next machine was blocked.
D1-145571791
D1-145633801
D1-145658101
There was an IPC communication error when you pressed the display,
check and setup feeders button on the station software and the view
changed to
deactivated feeders
.
D1-145603609
D1-143839501
Sporadically the station software stopped during placement with error
message
30016 Unhandled exception error
.
D1-145691301 During production, gantry 2 stopped without any warning or error on the GUI.
D18294-3901 eSW: error message 35200 Board has not arrived in specified section.
Table 9-5: Corrected errors station software version 710.1 Patch 5
710.1 Patch 4
Error No.
Error description
D1-135126702 Head Verification: DP rotation and segment offset up tests were not possible.
D1-135126745
The Z axis movement and vacuum calibration tests failed but the machine
was ok.
D1-136288601 The board was transported into the input area and was not moved further.
D1-137766301 The teaching of acceleration values failed and component got lost.
D1-138967301 The use of an alternative LDU on the same table was not supported.
D1-139882801
The WPC tray was still moving when the head was ready for pick up. This
slowed down the machine.
D1-140734101
Head cycle count did not match between SIPLACE Pro optimized results and
actual machine run.
D1-141055501
Error message 35026 Pickup location is not ready although the
feeder seemed to be ready.
D1-141676501
Pocket recognition after a manual teaching process added the new position
value to the formerly detected one.
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
32
D1-141676541
The gripper got lost and the machine reported 30482 Z axis is beyond
maximum position, position is in empty space, segment: 2
but did not stop.
D1-142007061
eSW: conveyor: changing conveyor mode from double back to single did not
work.
D1-142180007
Measuring all components after placement lead to the error message: y
axis 1 power supply not sufficient
.
D1-142505151
The station reported 40034 CAUTION: Do not move gantry! The
head lost a nozzle
although the gripper was not lost.
D1-142765001
Fill level change
after
consumed
event from station caused problems.
D1-142800301
Sporadically the station SW stopped during placement with error message
30016 Unhandled exception error
.
D1-142915801 During production run there was no placement in placement area 2.
D1-143004545 The station could not be stopped and had to be switched off.
D1-143141501
The current of the lifting table motor was too low at conveyor motor
verification.
D1-143195601
Suddenly the station software did not react any longer and had to be
rebooted.
D1-143204201
eSW: The lifting table moved downwards into the mechanical limit as soon as
a board arrived in the placement area.
D1-143231401
The multistep calibration stopped with an error message when the results
were saved.
D1-143475401
The SIPLACE Pro components which were assigned to specific reference
designators differed to those in SIPLACE Pro.
D1-143605001 Plausibility check showed wrong error message.
D1-143635102 eSW: the overlapping of the X- and Z-axes during pick up was not correct.
D1-143683801
A new program was downloaded with activated snap in verification.
Afterwards the snap selection ran endlessly. Anschließend lief die Snap-
Auswahl in Endlosschleife.
D1-143697601 The polarity check during re-filling did not work.
D1-143744601 The X feeder index LED did not show the correct status.
D1-143783201
The whispering of board barcode was active although the machines were not
defined as a cluster.
D1-143958512 The component in the tray could not be reached.
D1-144006701
The software hung up when the changes of OSC component teaching were
saved.
D1-144031036
The station GUI was not refreshed after download. The previous job was
displayed on the screen.
D1-144063301
A wide connector on TH segment 2 was wiped off by the aperture collar of
segment 1.
D1-144172401 Vision dumps could not be filtered by location.
D1-144388801
During preparation work for new production there was the error message
32602 The software has stopped unexpectedly. Shut down
Windows, then restart the station
.
D1-144618801 Components were not available for teaching.
Station Software 711.1 (R18-1) / Version Description 05/2018 Edition
33
D1-144666909
Automatic pin recognition with 8mm feeder: OIS erroneously was counting a
reject.
D1-144698005
A component was marked for teaching before placement. When the new
position was saved the software hung up.
D1-144711401 The thresholds were not recalculated when the recipe was changed.
D1-144728801 The station software hung up after a mechanical change of the conveyor.
D1-144830807 The nozzle could not be returned if there was still a component on the nozzle.
D1-144854701
eSW: the motor for the width adjustment could not be calibrated (SX 1/2 with
single conveyor).
D1-144860701
Error message 34036 Y axis mapping data not activated when Y
mapping was executed and the mapping data should be restored.
D1-144868153
The station software stopped during/after placement with error message
30016 Unhandled exception error
.
D1-144890453
Dirty glue feeder lead to error message 34432 Fatal error, maximum
number of retries reached
.
D1-145008101 Error message:
34641 Cannot reject nozzle
.
D1-145043932
When a gantry did no longer travel over the current board, because high
components were placed by the head of the other gantry, the inapprehensible
message 32539 Beware of collision with high components on
board
was displayed.
D1-145070937 The DUMP archive was not deleted after an auto bug report.
D1-145384201 Unexpected software malfunction - the application had to be closed.
D17845-17170
When we taught and accepted the placement position, the teach offset
x/y/angle in the placement list changed automatically even though we did not
change it.
D17933-41707
The CPP head moved continuously left and right without picking up the
component on the waffle pack of the WPC6.
D18093-21501 The software hung up with the error message that ISS did not respond.
D18093-22703
Sporadically the station SW stopped during placement with the error
messages 30016 Unhandled exception error and 32602 The
software has stopped unexpectedly
.
D18093-22757 Error message
34488 Placement head is unable to continue
.
D18170-42001 There were inconsistent nozzle scan results and misleading error messages.
D18364-1423
The production stopped without any error message after having recognized
the fiducials.
D18400-101
Gantry1 stopped with message 32535 Checking nozzle
configuration: C&P20 P Head
.
D18403-209 eSW: The X-axis motor hit the buffer mount of the X-axis.
Table 9-6: Corrected errors station software version 710.1 Patch 4