Tape Feeder Modules
Error Messages Error Messages for 3x8 mm S/SL
52 User Manual SIPLACE S-Feeder
2.5 Error Messages
2.5.1 Error Messages for 3x8 mm S/SL
All error messages are shown on the control unit display.
PFx (x = track 1, 2 or 3) pickup position incorrect
The drive has not reached its end position.
►Check the tape path (including the empty tape path) for any blockages or stiff movement.
►After fixing the error, acknowledge the error message by pressing the green "Index" button or the
yellow "Foil" button.
Fox (x = track 1, 2 or 3) foil error
▪ Foil torn:
– Insert the foil again and hold the yellow "Foil" button pressed until the motor switches off.
If the foil is tensioned correctly, the control unit display will change to show the set step size.
▪ Foil not removed:
– Press rocker 2 and wait until the foil motor switches off.
– Pull the foil out a little and then out from under the pickup window (you may need to open and
then close the pickup window).
– Tension the foil by pressing the yellow "Foil" button until the foil motor switches off.
If the foil is tensioned correctly, the control unit display will switch over to the set step size.
dAE data error
The feeder data storage process was not completed properly when the equipment was last switched off.
This display only appears for approx. 3 seconds at switch on.
Measure:
The feeder is defective and needs to be repaired.
CoE communication error
The feeder is unable to access data in the EEPROM. This display will only appear for approx. 3 seconds
at switch on.
Measure:
The feeder is defective and needs to be repaired.
Supply voltage (+30V DC) too low
The feeder is no longer ready for operation.
Measure:
Check whether this error message is caused by the FCU or by the feeder.
If multiple feeders on the same changeover table show this same error message, the FCU is probably
defective or the voltage supply to the FCU is faulty.
If only one feeder shows the above mentioned error message and if this message is also shown when
the feeder is connected to another changeover table, the feeder is defective and needs to be repaired.

Tape Feeder Modules
Error Messages for 12/16, 24/32, 44, 56, 72, 88 mm S / S DP Error Messages
User Manual SIPLACE S-Feeder 53
2.5.2 Error Messages for 12/16, 24/32, 44, 56, 72, 88 mm S / S DP
All error messages are shown on the control unit display.
PF pickup position incorrect
The drive has not reached its end position.
►Check the tape path (including the empty tape path) for any blockages or stiff movement.
►After fixing the error, press any button on the control unit and hold this pressed.
The control unit display will show:
EE (Error erased)
►Release the button.
The control unit display will show the set step size.
►Now check the pickup position and adjust this if required.
In the case of this error, the transport wheel might not audibly touch the end stop when it sets the pickup
position in 2 mm mode. if this occurs, leave the 2 mm mode and initiate a transport run with the set step
size.
If the end stop is still not audibly touched, initiate another transport run and apply pressure to the drive
motor during the transport run, by tugging slightly on the tape material.
►Now set the pickup position in 2 mm mode.
The feeder is now ready for operation again.
Fo foil error
▪ Foil torn:
– Check the foil pretension and adjust this, if necessary.
– Insert the foil again and hold the yellow "Foil" button pressed until the foil motor switches off.
If the foil is tensioned correctly, the control unit display will switch over to show the set step size.
▪ Foil not removed:
– Check the foil pretension and adjust this, if necessary.
– Press rocker 2 and wait until the foil motor switches off.
– Pull the foil out a little and then out from under the pickup window (you may need to open and
then close the pickup window).
– Tension the foil by pressing the yellow "Foil" button until the foil motor switches off.
If the foil is tensioned correctly, the control unit display will switch over to show the set step size.
EE error deleted
(Error is deleted, only appears with the error message PF)
NOTICE
In this function state you can initiate transport runs, adjust the step size or operate in 2 mm
mode. If one of these functions is enabled, the flashing error message will be temporarily
hidden (display according to function state).
Tape Feeder Modules
Error Messages Error Messages for 12/16, 24/32, 44, 56, 72, 88 mm S / S DP
54 User Manual SIPLACE S-Feeder
CoE communication error
The feeder is unable to access data in the EEPROM. After reconnection, a step size of 4 mm is always
shown since the system is unable to save the step size last set. The tape width is no longer known and
the max. step size setting is no longer limited. The step size can now be set up to 56 mm (from firmware
V1.6 to 96 mm).
Measure:
The feeder is defective and needs to be repaired.
- - Supply voltage too low
The feeder is no longer ready for operation.
Measure:
Check whether this error message is caused by the FCU or by the feeder.
If multiple feeders on the same changeover table show this same error message, the FCU is probably
defective or the voltage supply to the FCU is faulty.
If only one feeder shows the above mentioned error message and if this message is also shown when
the feeder is connected to another changeover table, the feeder is defective and needs to be repaired.