00197283-02_IM_LED_Pairing_V2_1_EN.pdf - 第17页
LED Pair ing / Ins tallatio n Manua l 05/2014 Edit ion 17 Figure 5- 16 : Availabilit y Che cking calculation for l eft line lane The rec ipe data is load ed to the SIPL ACE L ED Pairin g Con trol ler a nd the n ew sec ti…

LED Pairing / Installation Manual 05/2014 Edition
16
The recipe data of the line lanes will now be loaded to the SIPLACE LED Pairing Controller.
Figure 5-14: Recipe data for the left line lane
Board Grouping and Availability Checking are active for the left line lane.
If necessary, you can add additional sections to the line (conveyor belts, overlapping buffers etc.).
Sample
In the following sample, 3 sections shall be added between St1_X4 and St2_X3 on both line lanes.
Availability Checking is only active for the left line lane.
Figure 5-15: Adding sections
► Click the + sign between St1_X4 und St2_X3 and add 3 sections.
► Click on Set Config to save the configuration for the right lane.
► Repeat these steps for the left lane.

LED Pairing / Installation Manual 05/2014 Edition
17
Figure 5-16: Availability Checking calculation for left line lane
The recipe data is loaded to the SIPLACE LED Pairing Controller and the new sections are
considered in the new Availability Checking calculation.
5.1 SIPLACE LED Pairing Controller Database
The SIPLACE LED Pairing Controller requires a factory wide database that can be accessed from
all SIPLACE LED Pairing Controller instances to save and retrieve board related data. The
SIPLACE LED Pairing Controller database gets installed during installation of the SIPLACE LED
Pairing Controller and gets maintained and updated by OIB.
The SIPLACE LED Pairing Controller database consists of the BoardGrouping table that contains
entries used to implement a factory wide board grouping mechanism. A description of the
BoardGrouping table can be found in section 8.2.
5.2 Activating / Deactivating SIPLACE LED Pairing Controller
After installation, the Availability Checking and Board Grouping functions have to be activated in
SIPLACE Pro Desk. As default, this is done automatically. Further information can be found in the
SIPLACE LED Pairing User Guide.
If one of the functions or both of them are activated, the SIPLACE LED Pairing Controller performs
the correspondent check(s) and only allows boards to enter the line respectively.
If neither Board Grouping nor Availability Checking is activated, the SIPLACE LED Pairing
Controller allows any board to enter the line.
LED Pairing / Installation Manual 05/2014 Edition
18
6 Configuring SIPLACE LED Pairing Controller
The SIPLACE LED Pairing Controller depends on several OIB components to receive the required
data to perform the Board Grouping and Availability Checking functions. The configuration is done
in the OIB Operator Manager by assigning OIB adapters to certain Factory Layout nodes. The
SIPLACE LED Pairing Controller reads the configuration and tries to retrieve data from the OIB
service endpoints.
The SIPLACE LED Pairing Controller depends on the following OIB components:
– SIPLACE Pro Line Control Adapter
– SIPLACE Pro SPI Adapter
– SIPLACE Setup Center Adapter
– SIPLACE LED Pairing Controller database
– SIPLACE Monitoring Service Adapter (optional)
6.1 Checking Configuration
Two error cases may occur during the configuration check:
– Missing OIB connection, i.e. an OIB data source is not able to provide data.
– The SIPLACE LED Pairing Controller database cannot be accessed.