00197283-02_IM_LED_Pairing_V2_1_EN.pdf - 第29页
LED Pair ing / Ins tallatio n Manua l 05/2014 Edit ion 29 In the f ollowing windo w the SIP LACE LED Pair ing Cont roller ser vice ap pears as a conf igured service. Figure 8-7 : SIPLACE LED Pairing Controller configured

LED Pairing / Installation Manual 05/2014 Edition
28
In the following window they appear as configured services.
Figure 8-6: Configured services
► Install the SIPLACE LED Pairing Controller as described in chapter 5.
After installation, the SIPLACE LED Pairing Controller appears as an un-configured service in the
OIB Operation Manager.
► Configure the SIPLACE LED Pairing Controller service in the same way as displayed in Figure
8-3.

LED Pairing / Installation Manual 05/2014 Edition
29
In the following window the SIPLACE LED Pairing Controller service appears as a configured
service.
Figure 8-7: SIPLACE LED Pairing Controller configured

LED Pairing / Installation Manual 05/2014 Edition
30
8.2 SIPLACE LED Pairing Controller Database – Board Grouping
Table
The Board Grouping table of the SIPLACE LED Pairing Controller database contains the following
entries:
Board Grouping table LED Pairing Controller
name
Data type Byte CI I P
Line Full Path
strLineFullPath
nvarchar(1024) 2048
Recipe Full Path
strRecipeFullPath
nvarchar(1024) 2048
Conveyor Lane
lConveyorLane
int 4
PCB individual barcode
strBarcode
nvarchar(1024) 2048
Group Guid
strGroupGuid
nvarchar(36) 72
Type of entry
IType
int 4
State of entry
IState
int 4
Timestamp when entry
was written
dtLastProcessed DateTime 8
Table 7-1: Board Grouping table
Type of entry:
0: Undefined
1: Independent board entry
2: Dependent board entry
State of entry:
0: Undefined
1: IndependentBoardLineEntered
2: IndependentBoardProduced
3: IndependentBoardCanceled
4: DependentBoardLineEntered
5: DependentBoardProduced
6: DependentBoardCanceled