DeltaTherm_IR_REV_B-1.pdf - 第17页

Delt aTherm IR Cure Modul e Revision B / February 2020 Page 17 of 41 Cycl e St op Figure 10 : Cycle S top Options in Cycl e Stop ar e: Aut o Cycle , Manual, a nd Setup. Selec t “ F1 ” or th e auto cycl e icon to operate …

100%1 / 41
DeltaTherm IR Cure Module
Revision B / February 2020
Page 16 of 41
Machine Safety Check
When the machine is started, it must initialize. After it has initialized successfully, the
operator interface shows the following screen:
Figure 9: PVA Screen
The machine safety check ensures that the DeltaTherm IR Cure Module safety devices
(emergency stop, door interlocks, etc.) operate correctly. For the startup procedure, the
operator must start and complete the safety check successfully. After you start the safety
check, you must activate and deactivate the safety devices. Some safety checks are timed
and will cause a failure if the action is not done in the set time.
Shutdown Procedure
Do the following procedure to shut down the cure module.
1. Wait for all boards to clear the cure module.
2. Press Auto Stop on the OIT. Wait for the PVA screen to appear.
3. Wait one minute for the module to cool. The exhaust fan will be on.
4. Turn the main power switch to OFF.
5. Make sure you remove all parts before you shut down the cure module.
CAUTION: If you plan to perform maintenance during the shutdown, be sure to lock
out and tag the machine.
DeltaTherm IR Cure Module
Revision B / February 2020
Page 17 of 41
Cycle Stop
Figure 10: Cycle Stop
Options in Cycle Stop are: Auto Cycle, Manual, and Setup.
Select “F1or the auto cycle icon to operate the module in Auto Cycle.
Select “F3” or the manual icon to operate the module in Manual mode.
Select “ESC or the settings icon to go to Setup mode and view or
change the operating parameters of the module.
Select the Home icon or “F3” from any mode to return to Cycle Stop.
DeltaTherm IR Cure Module
Revision B / February 2020
Page 18 of 41
Auto Cycle
Auto Cycle is the normal operating mode for the DeltaTherm IR Cure Module. In Auto Cycle,
the cure module can operate as part of a production line. All communication with adjacent
machines is done without operator input. In Auto Cycle, the machine uses the parameters in
setup mode. The screen below shows Auto Cycle with four zones top and bottom.
Figure 11: Auto Cycle
1. The Panel Temperature shows the current temperature of the heater panel.
2. The Panel Temperature Setpoint shows the current recipe’s temperature setpoint
of the heater panel.
3. The At Temperature indicator will light up when the panel temperature is within
the allowable setpoint deviation value.
4. The Current Recipe Name will display at the top of the screen.
5. The Board Counter displays the number of boards in the oven. In the event of an
incorrect value (PIP flashing), press and hold for 5 seconds to reset this to zero
6. The Autocycle Messages section displays the current Auto Cycle state and status
messages.
7. Press to the Heater Panel Trend icon to view a graph of panel temperature values
over time.
8. To view the next set of panels and zones, press the Next Zone button.
9. The SMEMA Status shows the current status of SMEMA inputs and outputs.
10. The current Conveyor Speed will display at the bottom of the screen.