Delt aTherm IR Cure Modul e Revision B / February 2020 Page 24 of 41 Setup Mode In S etup mode , the op erator can set basic fu nctions of t he machine and Auto Cycle parameter s. These par ameters (d epending on the mac…

100%1 / 41
DeltaTherm IR Cure Module
Revision B / February 2020
Page 23 of 41
Sensors
The PIP Sensors can be monitored in Manual mode for correct operation.
Figure 16: Sensors in Manual Mode
Note: Process PIP will only show on 12 ft and 16 ft oven length systems.
SMEMA Control
1. The SMEMA inputs (Upstream Board Available and Downstream Ready) can be
monitored for correct operation through the SMEMA screen in Manual mode.
2. Select the necessary output (Machine Ready and Board Available) to toggle it on or
off.
Figure 17: SMEMA in Manual Mode
DeltaTherm IR Cure Module
Revision B / February 2020
Page 24 of 41
Setup Mode
In Setup mode, the operator can set basic functions of the machine and Auto Cycle
parameters. These parameters (depending on the machine) are the current recipe, IR panel
temperatures, allowable deviations, conveyor width, and conveyor speed. Parameters are
saved in the controller under the current recipe even when the module is shut down. Push
the Home button or the F3 button at any time to exit Setup mode and return to cycle stop.
IR Panels
Figure 18: Setup Zone 1 Panels
1. The Heater Panel Recipe Switch can disable or enable the use of a zone’s upper or
lower heater panel in Autocycle. If enabled, the panel will display a green
checkmark . If disabled, the panel will display a red X .
Note: IR panels cannot activate unless the exhaust fan is on.
2. The Setpoint box is the target temperature (display temperature is filtered) for
each zone and the deviation box is the permitted deviation from the setpoint for
that zone.
Touch the Setpoint box and a keypad will be shown.
Enter the necessary value. The system minimum and maximum are shown
below the numeric field.
Press “ENT” to save the value and close the keypad.
DeltaTherm IR Cure Module
Revision B / February 2020
Page 25 of 41
3. The Actual Temperature displays the current actual temperature of the heater
panel.
On double-sided ovens, the upper and lower panels for each section are
controlled as one zone. The display temperature is the average temperature
(display temperature is filtered) of the upper and lower panel.
Note: With two-sided IR ovens, the upper panels may indicate temperatures higher
than the setpoint due to absorption of energy from the lower panels. This is normal.
4. The Max Deviation is the max allowable deviation from the target setpoint for the
specified zone and heater panel. Each enabled zone’s panels must reach and
maintain a temperature within the set deviations to run the product in Auto Cycle.
Touch the Max Deviation box and a keypad will be shown.
Enter the desired value.
Press “ENT” to save the value and close the keyboard.
5. The Apply to All button will copy the setpoints and deviations of the Zone 1 upper
and lower panels to all over zones.
Note: Zone enable/disable options will not be copied over.
6. The name of the current Recipe will display. Any changes made to the recipe field
values will automatically be saved to the current recipe. Recipes are configured in
OEM mode.