DeltaTherm_IR_REV_B-1.pdf - 第21页
Delt aTherm IR Cure Modul e Revision B / February 2020 Page 21 of 41 Conve yo r Spee d The Conve yor Sp eed can be set in M anual mode. 1. Select the S peed bo x to manually e nter conv eyor speed. The m e tric/standard …

DeltaTherm IR Cure Module
Revision B / February 2020
Page 20 of 41
Manual Mode
IR Panels
The panel temperature is shown for each zone. A zone is an area in the oven that is
controlled and monitored independent of other areas. Usually an oven has four zones.
Figure 12: Manual IR Panels
1. Select the Heater Panel switch to turn the desired panel on or off. The indicator to
the left of the switch will show the heat output. The heater panel will heat up to the
current setpoint.
2. The Setpoint boxes are the target set points for each zone and heater panel. To
change the target Setpoint, press the designated box. A new screen will be shown.
• The left side box in the Zone Control area is the target temperature (display
temperature is filtered) for each zone and the deviation point for that zone.
• Touch the screen and a keypad will be shown.
• Enter the necessary value.
• Push ENT, and the zone screen will be shown again.
3. The Actual boxes show the actual temperatures (display temperature is filtered) for
each zone.
4. Select Apply to All to copy the setpoints of the Zone 1 upper and lower heater panel
to every zone and panel.
5. Select the View Trend icon to view each panel’s temperature history on a graph.

DeltaTherm IR Cure Module
Revision B / February 2020
Page 21 of 41
Conveyor Speed
The Conveyor Speed can be set in Manual mode.
1. Select the Speed box to manually enter conveyor speed. The metric/standard u nit
range is .03 – 15.3m/min (.1 - 50.2ft/min).
• The keypad will be shown, enter the necessary value.
• Select ‘ENT’ to save.
2. Press the red X icon or green checkmark icon to toggle the conveyor
between on and off.
Figure 13: Conveyor Control in Manual Mode
Conveyor Width
Figure 14: Conveyor Width in Manual Mode

DeltaTherm IR Cure Module
Revision B / February 2020
Page 22 of 41
The Conveyor Width can be set in Manual mode.
1. Press to manually enter the target conveyor width setpoint.
• Touch the screen and a keypad will be shown.
• Enter the necessary value.
• Push ‘ENT’, and the zone screen will be shown again.
2. Press to move the current target conveyor width setpoint.
Note: Prior to the move, the machine will check for any boards.
3. Press to rehome the conveyor width.
Note: Prior to the move, the machine will check for any boards.
Conveyor Jog
Figure 15: Conveyor Jog in Manual Mode
1. This screen displays the current conveyor width.
2. Press to adjust the conveyor width. This will jog the conveyor width in a positive or
negative direction.