DeltaTherm IR Cure Module
Revision B / February 2020
Page 34 of 41
183
Zone 6A Deviation Fault
184
Zone 6B Deviation Fault
185
Zone 7A Deviation Fault
186
Zone 7B Deviation Fault
187
Zone 8A Deviation Fault
188
Zone 8B Deviation Fault
190
Master Conveyor Transfer (CAN3) Drive Mapping Fault
191
Master Conveyor Width (CAN4) Drive Mapping Fault
192
Slave Conveyor Transfer (CAN5) Drive Mapping Fault
193
Slave Conveyor Width (CAN6) Drive Mapping Fault
300
Conveyor Transfer (CAN3) Drive Enable Fault Initialization Failed
301
Conveyor Width (CAN4) Drive Enable Fault Initialization Failed
302
Conveyor Transfer (CAN5) Drive Enable Fault Initialization Failed
303
Conveyor Width (CAN6) Drive Enable Fault Initialization Failed
304
Conveyor Transfer (CAN3) Drive Enable Fault Ready to Switch On State Failed
305
Conveyor Width (CAN4) Drive Enable Fault Ready to Switch On State Failed
306
Conveyor Transfer (CAN5) Drive Enable Fault Ready to Switch On State Failed
307
Conveyor Width (CAN6) Drive Enable Fault Ready to Switch On State Failed
308
Conveyor Transfer (CAN3) Drive Enable Fault Switch On State Failed
309
Conveyor Width (CAN4) Drive Enable Fault Switch On State Failed
310
Conveyor Transfer (CAN5) Drive Enable Fault Switch On State Failed
311
Conveyor Width (CAN6) Drive Enable Fault Switch On State Failed
312
Conveyor Transfer (CAN3) Drive Enable Fault Operation Enabled State Failed
313
Conveyor Width (CAN4) Drive Enable Fault Operation Enabled State Failed
314
Conveyor Transfer (CAN5) Drive Enable Fault Operation Enabled State Failed
315
Conveyor Width (CAN6) Drive Enable Fault Operation Enabled State Failed
316
Conveyor Width (Master) Drive Runaway Fault
317
Conveyor Width (Slave) Drive Runaway Fault
Figure 23: Error Messages

DeltaTherm IR Cure Module
Revision B / February 2020
Page 35 of 41
Troubleshooting
If Something Goes Wrong . . .
Some problems are easy to identify and solve, others may require more extensive help. This
troubleshooting section is designed to assist an operator in solving many problems before
seeking additional help.
Refer to this Troubleshooting section if a mechanical or electrical problem occurs before
you call Technical Support.
Calling Technical Support
The Technical Support staff is available to help solve any problems. The phone number is
+1 518-371-2684. Have the following information when you call for help:
• All the information on the OIT when the error occurred.
• The operation in progress when the machine developed trouble (when did it have
problems, what was it doing, etc.).
• If the error was not serious, attempt to repeat the error. If the error does not repeat,
the problem may have been operator generated.

DeltaTherm IR Cure Module
Revision B / February 2020
Page 36 of 41
Fault Diagnosis
Operation Other Symptoms Possible Cause Corrective Action
The machine is ON.
And the operator
interface does not
have power
Cables are loose or not
connected
Examine the cable connections
Correct any loose connections
The electrical
enclosure does
not have power
The electrical enclosure is
open and the safety switch
is in the open position
Close the electrical enclosure
The fuse is blown
Examine the fuse in the PLC
power supply and correct
Power On button
does not stay on
Safety relay failed
Examine the relay and replace if
necessary
The bulb is blown Examine the bulb and replace
A door is open Close all doors
The emergency stop is
engaged
Disengage the emergency stop
Board does not
transfer to or from
adjacent station
The SMEMA connection is
broken
Examine the cable connections
Correct any loose connections
A module in the system is
turned off
Turn on the inactive module
IR Panels do not
operate or they fail
The panel temperature is
set below room
temperature
Change the setpoint
The fuse is blown
Examine the related fuses in the
electrical enclosure
The solid-state relay
failed
Replace the relay
The temperature is out of
range
Increase the deviation
The module is over-
temperature.
Decrease the setpoint
Exhaust fan failure
The fuse is blown Examine and correct the related
fuses
Figure 24: Fault Diagnosis