12-59 Machine Calibration 备 注 Head XY Offset Calibration 基准值如下。 Head 1 X:-0.06mm~0.06mm, Y : -0.05mm~0.05mm Head 2 X:14.94mm~15.06mm, Y : -0.05mm~0.05 mm Head 3 X:29.94mm~30.06mm, Y : -0.05mm~0.05 mm Head 4 X:44.…

12-58
Samsung Component Placer SM481 Administrator's Guide
11. <Gantry>组合框中选择Gantry2后,与Gantry1相同的方式执行校正。
结果值可在Head Offset对话框中确认。

12-59
Machine Calibration
备 注 Head XY Offset Calibration 基准值如下。
Head 1
X:-0.06mm~0.06mm, Y: -0.05mm~0.05mm
Head 2
X:14.94mm~15.06mm, Y: -0.05mm~0.05mm
Head 3
X:29.94mm~30.06mm, Y: -0.05mm~0.05mm
Head 4
X:44.94mm~45.06mm, Y: -0.05mm~0.05mm
Head 5
X:59.94mm~60.06mm, Y: -0.05mm~0.05mm
Head 6
X:74.94mm~75.06mm, Y: -0.05mm~0.05mm
Head 7
X:89.94mm~90.06mm, Y: -0.05mm~0.05mm
Head 8
X:104.94mm~105.06mm, Y: -0.05mm~0.05mm
Head 9
X:119.94mm~120.06mm, Y: -0.05mm~0.05mm
Head 10
X:134.94mm~135.06mm, Y: -0.05mm~0.05mm

12-60
Samsung Component Placer SM481 Administrator's Guide
12.3.7.5. Fly Camera Scale Calibration
测量飞行相机的标度(Scale)。为了执行飞行相机的标度校正作业之前首先要确认校
正 Tool 是否在ANC的校正 Tool处。
下面是 Fly-Camera Scale Calibration的校正步骤。
1. 点击<准备吸嘴>按钮,在ANC 1号孔中插入CN400吸嘴。
2. 选择<自动下一步> 校验框后,点击<10. Fly Camera Scale> 按钮,则对选择的
Gantry自动执行校正。
选择<没有实际运动(手动)> 校验框后,执行校正会在各 Head手动插入吸嘴,
并点击<下个>进入下一个阶段。
不选<自动下一步> 或<没有实际运动(手动)>中的任何校验框的状态下执行
校正时,虽然对当前被选的Head自动更换吸嘴,但要点击 <下个>按钮才能执行
下一个阶段。
点击<10. Fly Camera Scale>按钮则显示”首先,我们必须把所有吸嘴手动离开朝
向。将Z轴调制低处,点击[下一步]”消息。为了手动除去所有贴装在磁头的吸
嘴,拉下磁头的Z轴请点击 <下个> 按钮。
3. 那么,磁头组件(Head Assembly)移动到设备指定的位置后,下降所有 Z轴。此
时,请手动除去所有已安装的吸嘴。
4. 显示”下一
步,将标准工具粘贴在头部 1。点击[下一步]向下移动。移动后,手动
粘贴工具到首部。”消息。在磁头1的吸嘴支架上手动安装CN400吸嘴后请点击
<下个>按钮。
5. 显示 “移动到中心位置工具摄像移动,点击[下一步]” 消息。为了把Head
Assembly移动到ANC上的Calibrration Tool位置,请点击<下个>按钮。
6. 示”排列高度上升,镜像关闭。移动,点击 [下一步]”消息。请点击 <下个>按
钮。