Installation MTC 2
System requirements
User Manual SIPLACE S-Feeder Test Station 11
3
3 Installation MTC 2
Installation MTC 2
3.1
3.1 System requirements
System requirements
The PC, on which the
S-Feeder test software
is to be installed, must fulfill the following minimum require-
ments.
Operating system
Windows XP SP2/SP3
Windows 7 (32/64Bit)
Hardware requirements
Pentium 4 / Athlon 2 GHz, minimum 750 MB RAM
Graphics card or onboard graphics with minimum of 64 MB graphics memory
1 serial port (COM port RS232)
1 USB 2.0 port
CD drive
Required free hard drive memory
For the
S-Feeder test software
max. 380 MB
▪For
Microsoft .NET Framework
(if not yet available) 280 MB
Screen resolution
Minimum monitor resolution 1024x768
3.2
3.2 Installing the Software
Installing the Software
Installation of the S-Feeder test software takes approx. 10 minutes.
Make sure that you are logged onto the computer as administrator.
Insert the CD "S-Feeder test station software" into the CD drive of the PC that you use to
to check their feeder, and then close the CD drive.
Start the
Setup.exe
program form the CD.
NOTICE
System Test
The S-Feeder Test Software has only been tested on SIPLACE Pro computer with the respec-
tive Windows XP version. This computer can be ordered incl. the Windows operating system
by part number 00116366-xx.
WARNING
Installation on a computer where SIPLACE Pro or the Vision Teach station is installed
The
S-Feeder test software
may currently NOT be installed on a PC on which the applications
SIPLACE Pro
or
Vision Teach Station
are already installed, as this could lead to version con-
flicts which cause malfunctions in these applications.
NOTICE
Installation in general
During the installation the USB camera must be unplugged.
Following the installation the SFT must be calibrated. Please ensure to have the calibration
standard available.
Installation MTC 2
Installing the Software
12 User Manual SIPLACE S-Feeder Test Station
The following dialog box will open.
Click on the Framework button to install
.
net-Framework on the computer. If
.net-Framework
is al-
ready on the computer, the Framework button will be disabled (grayed out).
Click on the OK button, to install the
S-Feeder test software
on the computer.
The following dialog box will open.
(1) Enable the option Licence conditions.
(2) Click on the Next button.
The following dialog box shows the SW packages to be installed.
NOTICE
Language selection
The language selection applies only to the language of the setup procedure and does not affect
the language of the application.
Installation MTC 2
Installing the Software
User Manual SIPLACE S-Feeder Test Station 13
To start the installation of the S-Feeder test software, click on the Install button.
Once the software installation has been completed successfully, the following dialog box will be shown.
NOTICE
Software Options
Since all software options are needed, there is no way to select (check mark remain).
NOTICE
Update / delete software
Confirm the "remove older feedback" by click on "OK" and "Finish". The installation of the SFTS
2.x deletes the previous version automatically.