00196591-04 UM S-Feeder Test Station EN.pdf - 第5页

Introduction General User Manual SIPLACE S-Feeder Test Sta tion 5 1 1 I n t r o d u c t io n Introduction 1.1 1 . 1 G e n e r a l General For optimum organiza tion of your products, you need to ensure t he smooth and rel…

100%1 / 38
Contents
4 User Manual SIPLACE S-Feeder Test Station
5.2.3.5 Individual Measurements Deviate Greatly 28
5.2.3.6 Multiple Measurements in Sequence Deviate Greatly 28
5.3 Checking the Test Tapes 29
5.4 Creating an Error Report 29
6 Service Work Conveyor 31
6.1 Replace the ring light illumination board 31
6.1.1 Required Tools 31
6.1.2 Removal/installation of Lightning Board 32
6.1.3 Lighting adjustment 34
Introduction
General
User Manual SIPLACE S-Feeder Test Station 5
1
1 Introduction
Introduction
1.1
1.1 General
General
For optimum organization of your products, you need to ensure the smooth and reliable use of your feed-
er modules. You can achieve this by regularly checking your feeder modules, cleaning them when nec-
essary, servicing them and making sure that they are set correctly. These measures can significantly
reduce unscheduled downtime.
The
S-Feeder Test Station
consists of a testing device (
S-Feeder Checking Device
) and software sup-
port. The
S-Feeder Test Station
enables you to check the reliable process and functionality of your S
feeder modules with the help of an electronically supported sight check. This determines the current val-
ues and compares them to predefined tolerance values.
If the check finds that tolerance values have been exceeded, we recommend that you send the feeder
modules concerned for repair.
The
S-Feeder Test Station
can be used to check:
The general functionality of the feeder modules
The position of the teeth in the respective toothed wheel (pickup position)
The play of the toothed wheel in the and across the direction of feeding
The
S-Feeder Test Station
is designed for use with the following
SIPLACE
feeder modules:
1.2
1.2 Scope of Delivery
Scope of Delivery
The
S-Feeder Test Station
is delivered with the following:
▪1
S-Feeder Checking Device
, item no. 03071323-01
1 power pack, item no. 03041682-01
1 serial cable, item no. 03040362-01
1 set of testing tapes, item no. 03074708-01
1 CD with the
S-Feeder test software
, item no. 03076718-04
1 operating manual, item no. 00196590-03
Designation Item no.
2 x 8 mm S II 00141096-xx
3 x 8 mm S 00141098- xx
3 x 8 mm SL 00141088- xx
3 x 8 mm S; 0201/0402 00141099- xx
12/16 mm S 00141092- xx
24 / 32 mm S 00141093- xx
44 mm S 00141094- xx
56 mm S 00141095- xx
72 mm S 00141097- xx
88 mm S 00141070- xx
NOTICE
Operation
To use the S-Feeder Test Station, you need to have the calibration standard, item no.
03073729-01 (available as a separate option). This calibration standard is not supplied with the
feeder module as you only need one of these at each factory.enthalten
Introduction
Accessories
6 User Manual SIPLACE S-Feeder Test Station
1.3
1.3 Accessories
Accessories
00196590-03
The following accessories are available as options:
Calibration standard, item no. 03073729-01
Set of 8 mm master tapes, item no. 03074715-01
Set of 12/16 mm master tapes, item no. 03074717-01
1.4
1.4 EU Declaration of Conformity
EU Declaration of Conformity
The checking device is in conformity with the regulations and standards specified in the EU Declaration
of Conformity
Manufacturer:
ASM Assembly Systems
Rupert-Mayer-Str. 44
D-81359 München
1.5
1.5 Use of Symbols
Use of Symbols
Conventions for the Use of Hazard Symbols
Model Checking and setting device
Type S-Feeder Checking Device
Item No. 03071323-01
This typeface Marks controls and interface elements in the software.
Marks tasks which are to be performed by the user
NOTICE
Notice
as used in this Operation Manual provides information on the product or indicates a part of the
Operation Manual that requires particular attention.
CAUTION
Caution
as used in this Operation Manual means that slight injury or damage to equipment may occur
if the caution instructions are not followed.
WARNING
Warning
as used in this Operation Manual means that death, severe injury or considerable damage to
equipment may occur if the warning instructions are not followed.