Galaxy EX Squeegee Module.pdf - 第7页

SQUEEG EE MODULE REPLACEMENT PRO CEDURES Ch apte r Issue 4, J un 18 Tech nical R efere nce Ma nual 10.7 REPLACEMENT PROCEDURES ProFlow to Squeegees CAUTION SOLDER P AS TE AND SOL V ENTS. W HEN USING OR HANDLING ANY SOLDE…

100%1 / 30
SQUEEGEE MODULE
ELECTRICAL SCHEMATIC
10.6 Technical Reference Manual Chapter Issue 4, Jun 18
ELECTRICAL SCHEMATIC
Squeegee
Front
Home
(9SE04)
Squeegee
Rear
Home
(9SE05)
Rear
Squeegee
Stepper
Motor
(9M4)
Motor 1 B-
Motor 1 B+
Motor 1A-
Motor 1A+
Motor 2 B-
Motor 2 B+
Motor 2A-
Motor 2A+
Print Carriage
9PL16
9PL08
9PL17
0V
+V
-IN
+IN
Strain Gauge Bridge
(9SE6)
Spring Beam
9SK11
9SK12
Print Carriage I/O
Node 3
N3PL16
M36PL35
N3SK2
N6PL3
CAN BUS
PC
Motherboard
M36PL35
USB
M36Pl28
NextMove ES
(I/O Node 1)
NextMove
Interface
Dual Stepper
Card X2
M36 Machine Control
Step 3
Step 4
Front
Squeegee
Stepper
Motor
(9M3)
M36PL21
M36PL12
M36PL21
CAN
In
Rising
Table
Node 6
N6SK2
SQUEEGEE MODULE
REPLACEMENT PROCEDURES
Chapter Issue 4, Jun 18 Technical Reference Manual 10.7
REPLACEMENT PROCEDURES
ProFlow to
Squeegees
CAUTION
SOLDER PASTE AND SOLVENTS. WHEN USING OR HANDLING ANY SOLDER
PASTE OR SOLVENT FORMULATION THE MANUFACTURERS’ SAFETY DATA
SHEETS MUST BE STRICTLY ADHERED TO.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
Instances may occur when the machine is required to print using the squeegee
module configuration. The following procedure details how to revert the
machine from ProFlow use to the squeegee configuration:
Removing ProFlow 1. Select Maintenance.
2. Select Diagnostics.
3. Use Next or Previous to highlight ProFlow.
4. Select Select Module.
5. Ensure Home ProFlow is highlighted.
6. Select Run Diagnost.
7. Select Exit.
8. Select Exit.
9. Select Back.
10. Select Open Cover Commands.
11. Select Carriage To Front.
12. Select Back.
13. Select Shut Down and switch the mains isolator to OFF.
SQUEEGEE MODULE
REPLACEMENT PROCEDURES
10.8 Technical Reference Manual Chapter Issue 4, Jun 18
14. Disconnect both curly air lines from the self-seal pneumatic connectors sit-
uated either side of the ProFlow printhead mechanism.
15. Disconnect the three ProFlow mechanism connectors from the print car-
riage, left hand side:
• ProFlow Motor
• Home Sensor
• ProFlow Paste Level Sensor
16. Manually raise the ProFlow pressure mechanism by pulling the latch on
the front of the unit and lifting the mechanism to the fixed raised position.
17. Open the locking clip, securing the transfer head to the pressure mecha-
nism and carefully slide the transfer head out and away from the pressure
mechanism as indicated in the graphic below.
Pneumatic Connectors
Latch
ProFlow Motor
(9SK17)
Home Sensor
(9SK08)
ProFlow Paste Level