00198171-02_Technical_Training_FSE_TX-Series_EN.pdf - 第145页
9 Station Software Overviews 9.7 Maintenance GUI Technical Training FSE SIPLACE TX-Series 01/2018 145 Check the anti glare shield by turning the DP and the component sensor. (C&P20 A/M Heads only). Report for the mai…

9 Station Software Overviews
9.7 Maintenance GUI
144 Technical Training FSE SIPLACE TX-Series 01/2018
Content Preventive Maintenance page
Status overview of Vacuum-, height- and scan values with the production nozzles shows the dis-
abled DP´s and EXIT Button back to Maintenance GUI.
Return nozzle in the nozzle changer., Gantry moves in the Setup position and remove all tables if
possible (SX). Machine is ON.
Two cuts for selected tape cutter to check the blades and cycle time.
Check and show the Fan monitoring. (SIPLACE TX).
Check the filter disk via the component sensor on C&P20 Heads.
Pick up production nozzles to verify this nozzles with the next steps.
Check the seat of the nozzles on the DP´s. (all CPx Heads).

9 Station Software Overviews
9.7 Maintenance GUI
Technical Training FSE SIPLACE TX-Series 01/2018 145
Check the anti glare shield by turning the DP and the component sensor. (C&P20 A/M Heads only).
Report for the maintenance staff. Shows the results of all tests which was carried out and the com-
ments.
Endurance run with all main axes and head axes and a complete reference run 3 cycles.
Return production nozzle (pick up calibration nozzle if available), Gantry in Setup position and re-
move all table if possible (SX). Machine shut down.
Return all nozzle in the nozzle changer to remove the hole magazine and clean the nozzle.
9.7.3 Predictive Maintenance
User Level "Service Customer"
1. Show the maintenance status of the sub-
systems
2. Head test bench, complete head test and
reporting

9 Station Software Overviews
9.7 Maintenance GUI
146 Technical Training FSE SIPLACE TX-Series 01/2018
Content Predictive Maintenance page
Hardware Maintenance Data status information.
Before upgrading to Station software 709.1.
●
The maintenance cycle to should be set to “time based condition”, and the maintenance
status be reset.
●
Full maintenance be conducted.
Open new Window for Head verification checks with reports. For use of this feature refer to the
User Manual for the Head Care Station.
9.7.4 Verification
User Level Advanced production
1. Machine verification with the service tool
ACT.
2. Verify heads, fast test less than 10min.
3. Verify camera with the Service tool FCCS.
4. Check the communication of all installed
cameras in the machine.
5. Check the parallelism of the conveyor rails.
6. Check all transport motors about the cur-
rent with limits.
7. Check all voltages which provide the
power supply.
8. Check the feeder pickup position without
any offsets.
9. Verify the CAN bus resistance.
Verification – Machine Verification
Machine verification is the function with the common ACT – tool with the reports to verify the accur-
acy of the machine.
Additional to the current function is that the placement program can be marked as "Permanent" in
SIPLACE Pro. If there are no changes on the hardware configuration the ACT programs are always
on available station. This permanent placement program can be deleted on the station.