00198171-02_Technical_Training_FSE_TX-Series_EN.pdf - 第82页

6 Conveyor System 6.8 Excercise: Conveyor System 82 Technical Training FSE SIPLACE TX-Series 01/2018 Maintenance content Interval Requirement Clean the X-fiducial bar All workflows ● Cleaning wipe ● Protective gloves lat…

100%1 / 168
6 Conveyor System
6.6 Analysis - Common Error List
Technical Training FSE SIPLACE TX-Series 01/2018 81
Station Software Setting
1. Select fixed conveyor rail
2. Select single mode and fixed rail
3. Select fixed conveyor rail
4. Accept and adjust configuration
6.6 Analysis - Common Error List
Code Error description Possible cause Action
40005 PCB jamming
Incorrect Transport
width
Wrong PCB size
Remove PCB, check PCB
and feed it again
Check width of conveyor,
adjust width if necessary
Remove PCB by hand, PCB
status always show present
in conveyor GUI
Refresh PCB status in GUI
Reset / teach board sensor
in I/O of conveyor GUI
4004
4006
35200
During placement, fidu-
cial cannot be found
Teach fiducial by GUI
Check / adjust width of con-
veyor
Remove and check PCB,
feed PCB again
Check program from
SIPLACE Pro
40035 During reference run
conveyor edge not found
Width adjust manually
after machine switch off
Check and record conveyor
width from GUI
Adjust conveyor width manu-
ally to recorded width
Calibrate width
6.7 Maintenance
Maintenance item for Conveyor system. For detailed information refer to the maintenance Job card.
Maintenance content Interval Requirement
Vacuum complete conveyor area All Workflows Cleaning wipe/vacuum cleaner
Recirculating ball screws and round shaft Workflow 3 Cleaning wipe, KM-wipe
Preserve the linear guidances Workflow 3
SIPLACE cleaning-tissue
Protective gloves latex
Clean the guide shafts Workflow 3 Cleaning wipe, KM-wipe
6 Conveyor System
6.8 Excercise: Conveyor System
82 Technical Training FSE SIPLACE TX-Series 01/2018
Maintenance content Interval Requirement
Clean the X-fiducial bar All workflows
Cleaning wipe
Protective gloves latex
TX micron 15μm:
Clean the -fiducial bar
All workflows
Cleaning wipe
Protective gloves latex
Lifting table statilizer Workflow 4
Ben 32
6.8 Excercise: Conveyor System
1. Which of the following statements is incorrect?
A Dual conveyor with outer fixed rail is the standard configuration for TX.
B Single conveyor is option for TX1.
C The conveyor system is controlled by two TSP420 control boards.
D The fixed rail is fixed by two screws, and it is possible to reconfigure.
2. What action is necessary after exchanging the lifting motor for TX?
A Adjust the belt tension for conveyor transport tooth belt.
B No action required.
C Calibrate the ZPC for the lifting motor.
D Calibrate the ZPC for lifting motor and the current value for lifting motor.
3. What needs to be calibrated after exchange of the vacuum tooling?
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
6 Conveyor System
Room for Your Sketches and Notes
Technical Training FSE SIPLACE TX-Series 01/2018 83
Room for Your Sketches and Notes