00198171-02_Technical_Training_FSE_TX-Series_EN.pdf - 第50页
5 Component Supply 5.1 Change Over Table (COT) 50 Technical Training FSE SIPLACE TX-Series 01/2018 5.1.3 COT Feeder Configuration Feeder capacity (Track width 8mm) Machine Locations With C&P20 P With CPP With Twin He…

5 Component Supply
5.1 Change Over Table (COT)
Technical Training FSE SIPLACE TX-Series 01/2018 49
5 Component Supply
5.1 Change Over Table (COT)
5.1.1 Location
T - Transport direction
1. Location 1 for Change Over Table (COT)
2. JTF-ML
3. Location 2 for Change Over Table (COT)
4. Button for docking/ undocking the Change
Over Table (COT)
5.1.2 Overview COT
1. Handle
2. Reel container/ Cartridge (option)
3. Guide roller
4. Waste bin
5. Actuator/ Safety switch
COT_TX: General
●
The TX COT are not interchangeable with other COT types or machines.
●
Two changeover tables with 40 tracks each can be used on TX1 and TX2 / TX2i machines,
thus a maximum of 80 tracks for 8 mm X feeders are available.
●
Machines with a JEDEC Tray feeder (JTF-ML) installed, only maximum 28 tracks of the COT
on the JTF-ML location can be used.
●
The table is pushed manually into the docking frame and then held in its position by means of
the claws of the docking unit.
COT_TX: Features
●
4 movable wheels for table exchange in narrow space.
●
Standard larger waste bin to reduce work for operator.
●
Optional 7" tape reel holder.
– each tape reel holder can accommodate 2 tape reels, so that up to ten 13" (optional 7")
tape reels can be positioned above the tape container.
Note: Optional 7" tape reel holder can not be used on TX micron.

5 Component Supply
5.1 Change Over Table (COT)
50 Technical Training FSE SIPLACE TX-Series 01/2018
5.1.3 COT Feeder Configuration
Feeder capacity
(Track width 8mm)
Machine Locations With
C&P20 P
With CPP With Twin Head
(only Location1)
TX2i Location 1 38 tracks 40 tracks Not Applicable
Location 2 38 tracks 40 tracks Not Applicable
TX1
TX2
Location 1 38 tracks 28 tracks
with JTF
28 tracks with JTF
40 tracks 40 tracks
Location 2 38 tracks 40 tracks 40 tracks
COT/Feeder inter-
faces to the
machine:
Automatic connection to machine during docking (no cables needed)
Feeder power supply
Feeder communication
Machine safety loop
Feeder compressed air connection
COT heights: 900 mm ± 15 mm
930 mm ± 15 mm (standard height)
950 mm ± 15 mm (SMEMA height)
The following SIPLACE Feeders can be used on the TX machine:
Name Type
X-Feeder Tape feeder types 4 mm X – 56 mm X
Linear feeders Linear feeder types _3x95Ax and _2x15Ax and_ 30Ax
Stick feeders Type smart stick_3x95X and _ 2x15X and _30X
Label feeder Tape feeder type label presenter Ax
LDU-X Processing feeder type Linear Dipping Unit X
GlueFeeder Processing feeder type GlueFeeder X
SIPLACE JTF-ML Tray feeder type JTF-ML_18X and JTF-ML_14X
Reject plate Reject plate TX
Restrictions LDU-X
●
There is a restricted pick-up area when using the LDU-X.
The LDU-X might not be place on the outer 6 tracks (left and right).
This results in restrictions in terms of component processing area.
●
The LDU-X can run together with CP20 P/M2, CPP and TH (only TX series). The LDU-X must
be manually placed in the set up.
●
Dipping area in Y-direction and access restriction on LDU for inner segment nozzle TH (only
TX-Series).
5.1.4 Height Adjustment
The COT height can be adjusted so that the transport heights of 900, 930 and 950 mm can be
reached.
The different default heights can be adjusted using the two cotter pins from the hollow shaft, placed
in three different positions.
●
A second person is needed for lifting the plate of changeover tables.
●
Raise the changeover table plate (3) slightly and knock the pins (2) out of the left and right
hollow shafts.
●
Move the table plate to the correct height.
●
Put back the 2 cotter pins (2) into the drilling hole (1) of the sleeve shaft.
●
Now the height had been adjusted.

5 Component Supply
5.2 Docking Station and COT Insert
Technical Training FSE SIPLACE TX-Series 01/2018 51
1. Drilling Hole
2. Cotter Pin
3. Table plate
CAUTION
The COT height should match the machine transport height as incorrect settings can lead
to damage when inserting or removing COT.
5.2 Docking Station and COT Insert
1. Docking claws (on the machine frame)
2. Safety switch
3. Empty tape duct
4. Nozzle station
5. Reject bin
6. FCU
7. Cylinder for claw
8. Feeder unlock device
9. Waste tape chute
●
The COT position is configured as "Speed application" for TX2i or "Flex application" for TX1
and TX2.
●
"Speed application" both location COT at inner position.
●
"Flex application" location 2 at inner position and location 1 at outer position.
●
Only location 1 is possible for the outer position.
1. Inner position
2. Outer position
3. Transport direction