3 Technical data User Manual SIP LACE CF 3.11 PCB conveyor Software Version S R.408.xx 03/2006 US Edition 104 3.1 1 PCB conveyor 3.1 1.1 Structure of the PCB conveyor The placem ent mach ine is su pplie d with a PC B con…

User Manual SIPLACE CF 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.10 Nozzle changer for the 6-segment Collect&Place head
103
Æ Push the spring hook (item 1) away from the magazine.
Æ Press the magazine so that it lies flat on the base, then release the spring hook. The spring
hook must latch into place.
3.10.7 Position detection
There is a position detection fiducial on every magazine.
Fig. 3.10 - 5 Position detection
3
(1) Positioning fiducial
(2) Position of the nozzles in the magazine with respect to the positioning fiducial

3 Technical data User Manual SIPLACE CF
3.11 PCB conveyor Software Version SR.408.xx 03/2006 US Edition
104
3.11 PCB conveyor
3.11.1 Structure of the PCB conveyor
The placement machine is supplied with a PCB conveyor. The left or the right side of the PCB
conveyor can be used as the stationary side, as required.
3
Fig. 3.11 - 1 PCB conveyor
3
(1) Input conveyor
(2) Center conveyor
(3) Output conveyor
(4) Lifting table
(5) Width adjustment
(T) Direction of PCB transport

User Manual SIPLACE CF 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.11 PCB conveyor
105
3.11.2 Technical data
3
PCB format
(length x width)
50 mm x 50 mm to 508 mm x 460 mm
(2" x 2" to 20" x 18")
Long board: length up to 610 mm (24") (available upon
request)
PCB thickness 0.5 mm to 4.5 mm
Max. PCB warpage Up: 4.5 mm - PCB thickness
Down: 0.5 mm + PCB thickness
Clearance on PCB underside 25 mm (standard), 40 mm (option)
PCB transport height 830 mm ± 15 mm (standard)
900 mm ± 15 mm (optional)
930 mm ± 15 mm (optional)
950 mm ± 15 mm (SMEMA: optional)
Fixed conveyor side Right (standard), left (optional)
Type of interface Siemens
SMEMA
Component-free PCB handling edge 3 mm
PCB changeover time 2.5 s
Bad fiducial detection Possible
Automatic width adjustment Possible