User Manual SIPLACE CF 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.7 Disabling the compressed air supply and discharging the pressure
55
2.7 Disabling the compressed air supply and discharg-
ing the pressure
2
Fig. 2.7 - 1 Compressed air unit on the placement system
(1) Shutoff valve lever in the CLOSED position
(2) Working pressure gauge
(3) Solenoid valve for venting the tape cutter during an EMERGENCY STOP
(4) Pressure gauge for the PCB stopper working pressure
(5) Compressed air supply, gantry 1
(6) Position of the compressed air unit
WARNING Never disconnect compressed air lines while they are pressurized. 2
CAUTION 2
When the machine is switched on, do not use the stop valve to interrupt the compressed air supply
for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to carry
out preventive maintenance or servicing work, you must switch the placement system off at the
main switch and disconnect it from the power supply. 2
2 Operational safety User Manual SIPLACE CF
2.7 Disabling the compressed air supply and discharging the pressure Software Version SR.408.xx 03/2006 US Edition
56
The compressed air working pressure is set to 0.52 MPa (5.2 bar). It may fluctuate between
0.5 MPa (5.0 bar) and 0.53 MPa (5.3 bar). The position of the compressed air unit is indicated by
item 5 in Fig. 2.7 - 1
. The compressed air supply to the machine can be interrupted using the shut-
off valve (item 1 in Fig. 2.7 - 1
).
You must remove the cover plate to use the shutoff valve.
Turn the lever on the shutoff valve (item 1 in Fig. 2.7 - 1
) from the vertical to the horizontal po-
sition.
Watch the working pressure gauge (item 2 in Fig. 2.7 - 1
) and the pressure gauge for the com-
pressed air supply to the stopper (item 4 in Fig. 2.7 - 1
). When the automatic placement system
is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
User Manual SIPLACE CF 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.8 Energy state of the machine after switching off at the main power switch
57
2.8 Energy state of the machine after switching off at
the main power switch
WARNING 2
Automatic placement systems from the SIPLACE family are powered with 3 x 400 V or 3 x
208 VAC (U.S.A. version) ± 5 %, 50/60 Hz mains voltage. This means that parts of the system
carry potentially fatal voltages - even when switched off at the main switch. Death, serious injury
or considerable damage may result if these automatic placement systems are handled incor-
rectly. Always follow the applicable accident prevention and DIN regulations (particularly
EN 60204, part 1). The guards over the control and servo units must ONLY be opened by appro-
priately qualified and trained personnel. 2
Fig. 2.8 - 1 Position of the control unit, servo unit, main switch, service socket and compr. air unit in the
placement system
(1) Main power switch Q1 (5) Control unit
(2) Compressed air unit (6) Power supply in the control unit
(3) Service socket (7) Measuring unit, servo unit
(4) Servo unit
GND
007
001 002 003 004 005 006
008 009
100VDC/
0VDC
30VDC 24VDC 12VDC 5VDC
100VDC
155VDC/0VDC
30VDC
7
6
GND
+24V
-15V
+15V
-12V
+12V
+5V
Fail
15
4
2
3
unswitched switched