User Manual SIPLAC E CF 2 Operational safety Software Vers ion SR.408.xx 03/2006 US Ed ition 2.8 Energy state of the machine af ter switching off at t he main power sw itch 57 2.8 Ene rgy st ate of the mach ine af ter sw…

2 Operational safety User Manual SIPLACE CF
2.7 Disabling the compressed air supply and discharging the pressure Software Version SR.408.xx 03/2006 US Edition
56
The compressed air working pressure is set to 0.52 MPa (5.2 bar). It may fluctuate between
0.5 MPa (5.0 bar) and 0.53 MPa (5.3 bar). The position of the compressed air unit is indicated by
item 5 in Fig. 2.7 - 1
. The compressed air supply to the machine can be interrupted using the shut-
off valve (item 1 in Fig. 2.7 - 1
).
– You must remove the cover plate to use the shutoff valve.
– Turn the lever on the shutoff valve (item 1 in Fig. 2.7 - 1
) from the vertical to the horizontal po-
sition.
– Watch the working pressure gauge (item 2 in Fig. 2.7 - 1
) and the pressure gauge for the com-
pressed air supply to the stopper (item 4 in Fig. 2.7 - 1
). When the automatic placement system
is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.

User Manual SIPLACE CF 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.8 Energy state of the machine after switching off at the main power switch
57
2.8 Energy state of the machine after switching off at
the main power switch
WARNING 2
Automatic placement systems from the SIPLACE family are powered with 3 x 400 V or 3 x
208 VAC (U.S.A. version) ± 5 %, 50/60 Hz mains voltage. This means that parts of the system
carry potentially fatal voltages - even when switched off at the main switch. Death, serious injury
or considerable damage may result if these automatic placement systems are handled incor-
rectly. Always follow the applicable accident prevention and DIN regulations (particularly
EN 60204, part 1). The guards over the control and servo units must ONLY be opened by appro-
priately qualified and trained personnel. 2
Fig. 2.8 - 1 Position of the control unit, servo unit, main switch, service socket and compr. air unit in the
placement system
(1) Main power switch Q1 (5) Control unit
(2) Compressed air unit (6) Power supply in the control unit
(3) Service socket (7) Measuring unit, servo unit
(4) Servo unit
GND
007
001 002 003 004 005 006
008 009
100VDC/
0VDC
30VDC 24VDC 12VDC 5VDC
100VDC
155VDC/0VDC
30VDC
7
6
GND
+24V
-15V
+15V
-12V
+12V
+5V
Fail
15
4
2
3
unswitched switched

2 Operational safety User Manual SIPLACE CF
2.8 Energy state of the machine after switching off at the main power switch Software Version SR.408.xx 03/2006 US Edition
58
2.8.1 Placement system switched off at the main power switch, but still
connected ...
The following table specifies the voltages of modules when the automatic placement system is
switched off at the main switch, but still connected to the mains supply.
2
2.8.2 Placement system switched off at the main power switch and disconnected
...
The automatic placement system is unpowered, apart from slight residual voltages in the servo
unit.
2.8.3 Compressed air conditions in the machine after switching off at the main
power switch
When the system is switched off at the main power switch (item 1 in Fig. 2.8 - 1) or if the power
supply fails, the electrically-controlled main valve Y1 of the compressed air unit closes (Fig. 2.7 -
1, page 55 ). The pressure will drop to 0 MPa (0 bar) within 5 seconds.
Module Voltage
Main power filter Z1
Terminals L1, L2, L3
3 x 400 VAC (3 x 208 VAC)
Service socket 230 VAC(115 VAC)
Main switch Q1
Terminals L1, L2, L3
Terminals T1, T2,T3
3 x 400 VAC (3 x 208 VAC)
0 VAC
Servo unit (item 7 in Fig. 2.8 - 1
)
Test socket 001
Test socket002
Test socket003
Test socket 004
Test socket 005
Test socket 006
Test socket 008
Test socket 009
GND007
< 12 VDC
< 12 VDC
< 12 VDC
0 VDC
0 VDC
0 VDC
< 12 VDC
< 12 VDC
Control unit (item 6 in Fig. 2.8 - 1
)
Test socket5 V
Test socket+ 12 V
Test socket– 12 V
Test socket+ 15 V
Test socket– 15 V
Test socket+ 24 V
GND
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
Tab. 2.8 - 1 Voltages of assemblies when the automatic placement system is switched off at the main switch,
but still connected to the main power