4 Setting up and commissioning 4.2 Retrofitting in the SIPLACE TX-Series 56 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 Fig.97: Wiring the SIPLACE JTF-ML2 at SIPLACE TX series V2 – part 2

100%1 / 94
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 55
Fig.96: Wiring the SIPLACE JTF-ML2 at SIPLACE TX series V2 – part 1
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
56 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
Fig.97: Wiring the SIPLACE JTF-ML2 at SIPLACE TX series V2 – part 2
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 57
4.2.5.11 Preparing the component trolley
Fig.98: Preparing the component trolley
Fit the dummy feeder(1) into place on
track 29(2) of the SIPLACE JTF
component trolley.
Move the SIPLACE JTF component
trolley into the machine.
4.2.5.12 Completing the mechanical work
Check and correct the height of the NC holder (see 7.1.2.1 "Setting the nozzle changer
height" [}89]).
Check and correct the height of the nozzle changer (see 7.1.2.2 "Setting the Nozzle Station
Height" [}90]).
Check the setting of the jumper on the NC (if one is present).
It must be set to 2-3 (see also 7.1.2.3 "Jumpers on the Nozzle Changer" [}91]).
Fit the NC and the nozzle station.
Install the used tape chute in location 1.
Move the component trolley into the machine.
Switch on the machine.
Make the settings in the software
See:
4.3 "Configuration of JEDEC tray feeders in SIPLACE Pro" [}62]
4.2.5.13 "Logging the SIPACE JTF-ML2 in at the software" [}57]
4.2.5.14 "Teaching the transfer position" [}58]
4.2.5.15 "Teaching the refill position" [}60]
4.2.5.13 Logging the SIPACE JTF-ML2 in at the software
Fig.99: Configuring the SIPLACE JTF-ML2
Configuration and calibration are performed
in the user level Service.
On first reboot with the SIPLACE JTF-
ML2, this needs to be entered in the
machine configuration. Select
Service Machine Configuration.
Select the SIPLACE JTF-ML at loca-
tion 1.
Save the changes.
Reboot the machine.