00198365-03_UM_JTF-ML2_TX12_V1-V2_EN.pdf - 第79页

5 Tasks on the machine 5.3 Operating the JEDEC tray feeder in the station software User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 79 (1) Operating functions of the trays Button Refill position - …

100%1 / 94
5 Tasks on the machine
5.3 Operating the JEDEC tray feeder in the station software
78 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
5.3.5 JEDEC Tray Feeder Settings
Fig.144: Track 11 highlighted (example of SIPLACETX2)
Select the JEDEC tray feeder for the
relevant track (1).
ð The feeder is highlighted in blue
color and the Settings menu (2) is
enabled for this feeder.
Fig.145: JEDEC tray feeder settings
(example of SIPLACETX2)
This view is displayed by selecting the Set-
tings button in the Single Feeder menu:
1. The selected tray is framed and dis-
played as Level 5.
2. Tray occupancy of the JEDEC tray
feeder
If the component is set up, the tray will
be displayed in green.
3. Selection buttons for trays (selection
via cursor is possible as well)
4. Position 1 for orientation
5. Picture of the selected tray (tray 5)
visualizing the current occupancy.
In this example, this first row has
already been picked up. (Gray = occu-
pied, white = empty)
6. Information on the component that is
currently in the feeding position.
7. Feeder on location (arrow keys for se-
lecting the feeder)
5.3.6 JEDEC Tray Feeder Settings – Functions
Fig.146: JEDEC tray feeder settings - functions
(example of SIPLACETX2)
The Settings menu provides a rough dis-
tinction of the functions:
1. Operating functions of the trays (see
below)
2. Cassette overview
3.
Filling level functions for selected tray
(see below)
4. Change button to switch to the level
view of the JEDEC tray feeder
5.
Position correction... for trays
5 Tasks on the machine
5.3 Operating the JEDEC tray feeder in the station software
User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 79
(1) Operating functions of the trays
Button
Refill position -
Move to refill posi-
tion, cassette1/2
The JEDEC tray feeder switches into the refill state.
If the active tray is part of the cassette to be changed, this tray is
moved back into the cassette.
If necessary, the "Stop production" function must be performed.
The cassette is moved into the refill position.
The door is unlocked.
The cassette can be removed from the JEDEC tray feeder.
Refill position -
Quit refill position
The door is locked.
The JEDEC tray feeder switches into the ready for operation state.
Provide Level
Selection of the level / tray in the cassette overview (directly by using
the cursor or the arrow keys).
The tray is then displayed in a frame.
The tray is moved into the pickup / transfer position (tray at position1).
If you select a different tray in the cassette overview, this tray is auto-
matically moved into the pickup/transfer position (tray at position1).
Confirm exchange
of cassette
All trays in the cassette are set to full and the exchange is confirmed.
Confirm exchange
of tray carrier
Only the selected tray in the cassette overview is set to full and the
exchange is confirmed.
(3) Filling Level Functions for Selected Tray (see below)
Button
Activate
Currently without information or function.
Set full
Sets the selected tray to full (every component in the tray is displayed
in gray color).
Set empty
Sets the selected tray to empty (every component in the tray is dis-
played in white color)
Change filling
level...
Opens a virtual tray. You can directly select the last occupied pocket
of the tray that contains a component.
An arrow represents the numbering direction that also corresponds to
the pickup direction.
The transfer position is always at the top.
In the following example, pocket 134 is selected as the pocket that
contains the last component. Pockets 135 to 160 shall be empty.
Please note that the selected pocket is difficult to recognize.
Fig.147: Change Filling Level - Pocket 26
Fig.148: Filling Level (Example of SIPLACETX2)
The current filling level displays pockets 1 to 26 as occupied. Pockets 27 to 40 are displayed as empty.
5 Tasks on the machine
5.3 Operating the JEDEC tray feeder in the station software
80 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
5.3.6.1 Position Correction
If necessary, perform a pickup position correction for the selected tray.
Teaching the pickup position for eccentric pickup.
Teaching the component center
5.3.6.2 Switching to Level View
Fig.149: Level View
Press the change button to display the
level view of the JEDEC tray feeder.
1. Position of the tray (14 or 18 levels)
2.
State indicates that a tray is present on
this level which is not used for this
setup. The filling level is not queried.
3.
Filling level: Actual - target
4.
Component: Component description
5.
Component shape: Component shape
name
Single Tray Selection
Fig.150: Single Selected Tray
The line for a single selected tray is high-
lighted in blue color.
Use the cursor to activate/select the tray.
You can now make settings for the tray and
assign different states.
Please note that the trays have been
selected in advance in the example in the
screenshot.
1.
Set empty: Sets the tray to "Out of
components". Use the Set full button
to set it back to full.
2.
Deactivate: Deactivates the complete
tray which is then marked as "Deactiv-
ated by operator". Use the Activate
button to set it back to active.