00196478-08_MM_SX12DX12_en.pdf - 第30页

Minor Maintenance Maintenance Work on the Gantry 4.3.1 Tools, Consumables, Spare a nd Wear Parts 30 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 4.3 4 . 3 M a in t e n a n c e W o r k o n t h e G a n t r y Maintenance Work…

100%1 / 80
Minor Maintenance
4.2.2 Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 29
4.2.2.2
4.2.2.2 Checking the Fans on the GCUs
Checking the Fans on the GCUs
Open the protective cover.
Check the function of the fan (2) on the GCU (1) by
holding your hand in front of the fan. You should be
able to feel a noticeable flow of air.
If the fan does not work, it has to be replaced by au-
thorized personnel (Fan GCU [03060954-xx]). For
details about how to remove the GCU, read the ser-
vice manual for the respective machine.
Repeat this check for all GCUs.
Minor Maintenance
Maintenance Work on the Gantry 4.3.1 Tools, Consumables, Spare and Wear Parts
30 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
4.3
4.3 Maintenance Work on the Gantry
Maintenance Work on the Gantry
4.3.1
4.3.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
Lint-free cloths [03082092-xx]
SIPLACE cleaning tissue [00315253-xx]
Protective latex gloves [00372972-xx]
Cotton gloves [00359087-xx]
Set of Allen keys
ESD wristband [00320279-xx]
4.3.2
4.3.2 Performing Maintenance Tasks
Performing Maintenance Tasks
See also
1.1.6 Safety Instructions for the Gantry [ ➙ 9]
1.1.2 Safety Instructions for Working with Strong Magnetic Fields [ ➙ 8]
4.3.2.1
4.3.2.1 Checking and Cleaning the Magnetic Surfaces of the X and Y Axes
Checking and Cleaning the Magnetic Surfaces of the X and Y Axes
4.3.2.2
4.3.2.2 Cleaning the X Axis Loose Bearing and Contact Surface
Cleaning the X Axis Loose Bearing and Contact Surface
Clean the magnetic surfaces of the X (2) and Y (1)
axes thoroughly over their entire length. Use a lint-
free cloth to remove any dirt from the magnetic sur-
faces. Where necessary, remove components with a
non-magnetic tool.Where necessary, remove compo-
nents with a non-magnetic tool.
In the event of damage or other problems, please
contact your SIPLACE Service team in Munich.
CAUTION!
Do not use any chemical cleaning agents!
Use a SIPLACE cleaning tissue to wipe the loose
bearing (1) for the X axis and its contact surface (2) .
Repeat these steps for the loose bearing on the other
side of the head mount.
Repeat these steps for all gantries.
Minor Maintenance
4.3.2 Performing Maintenance Tasks Maintenance Work on the Gantry
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 31
4.3.2.3
4.3.2.3 Cleaning the Y Axis Loose Bearing and Contact Surface
Cleaning the Y Axis Loose Bearing and Contact Surface
CAUTION!
Do not use any chemical cleaning agents!
Use a dry, lint-free cloth to wipe the two Y axis loose
bearings at (1) and (2) and their contact surface (3).
Repeat these steps for all gantries.