00196478-08_MM_SX12DX12_en.pdf - 第30页
Minor Maintenance Maintenance Work on the Gantry 4.3.1 Tools, Consumables, Spare a nd Wear Parts 30 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 4.3 4 . 3 M a in t e n a n c e W o r k o n t h e G a n t r y Maintenance Work…

Minor Maintenance
4.2.2 Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 29
4.2.2.2
4.2.2.2 Checking the Fans on the GCUs
Checking the Fans on the GCUs
► Open the protective cover.
► Check the function of the fan (2) on the GCU (1) by
holding your hand in front of the fan. You should be
able to feel a noticeable flow of air.
► If the fan does not work, it has to be replaced by au-
thorized personnel (Fan GCU [03060954-xx]). For
details about how to remove the GCU, read the ser-
vice manual for the respective machine.
► Repeat this check for all GCUs.

Minor Maintenance
Maintenance Work on the Gantry 4.3.1 Tools, Consumables, Spare and Wear Parts
30 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
4.3
4.3 Maintenance Work on the Gantry
Maintenance Work on the Gantry
4.3.1
4.3.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
▪ Lint-free cloths [03082092-xx]
▪ SIPLACE cleaning tissue [00315253-xx]
▪ Protective latex gloves [00372972-xx]
▪ Cotton gloves [00359087-xx]
▪ Set of Allen keys
▪ ESD wristband [00320279-xx]
4.3.2
4.3.2 Performing Maintenance Tasks
Performing Maintenance Tasks
See also
1.1.6 Safety Instructions for the Gantry [ ➙ 9]
1.1.2 Safety Instructions for Working with Strong Magnetic Fields [ ➙ 8]
4.3.2.1
4.3.2.1 Checking and Cleaning the Magnetic Surfaces of the X and Y Axes
Checking and Cleaning the Magnetic Surfaces of the X and Y Axes
4.3.2.2
4.3.2.2 Cleaning the X Axis Loose Bearing and Contact Surface
Cleaning the X Axis Loose Bearing and Contact Surface
► Clean the magnetic surfaces of the X (2) and Y (1)
axes thoroughly over their entire length. Use a lint-
free cloth to remove any dirt from the magnetic sur-
faces. Where necessary, remove components with a
non-magnetic tool.Where necessary, remove compo-
nents with a non-magnetic tool.
► In the event of damage or other problems, please
contact your SIPLACE Service team in Munich.
CAUTION!
Do not use any chemical cleaning agents!
► Use a SIPLACE cleaning tissue to wipe the loose
bearing (1) for the X axis and its contact surface (2) .
► Repeat these steps for the loose bearing on the other
side of the head mount.
► Repeat these steps for all gantries.

Minor Maintenance
4.3.2 Performing Maintenance Tasks Maintenance Work on the Gantry
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 31
4.3.2.3
4.3.2.3 Cleaning the Y Axis Loose Bearing and Contact Surface
Cleaning the Y Axis Loose Bearing and Contact Surface
CAUTION!
Do not use any chemical cleaning agents!
► Use a dry, lint-free cloth to wipe the two Y axis loose
bearings at (1) and (2) and their contact surface (3).
► Repeat these steps for all gantries.