00196478-08_MM_SX12DX12_en.pdf - 第49页
Major Maintenance 5.2.2 Performing Maintenance Ta sks Maintenance Tasks for Base Ma chine Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 49 5.2.2.5 5 . 2 . 2 . 5 C h e c k in g / C le a n in g / R e p la c in g t h e G a s P…

Major Maintenance
Maintenance Tasks for Base Machine 5.2.2 Performing Maintenance Tasks
48 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
5.2.2.4
5.2.2.4 Cleaning the Protective Covers
Cleaning the Protective Covers
CAUTION
ESD coating
► The choice of cleaning agent for the protective covers must be made with particular care so
as not to damage the ESD coating on the protective covers! Never use acid or strong alka-
line agents and avoid all ketones, esters, aromatics, halogenated hydrocarbons, etheric oils
or similar.
► Only apply light pressure as you clean the protective covers so as not to damage the ESD
coating!
► Check the protective covers for dirt.
► Clean them with a dry, lint-free cloth, if required.
► If they are very dirty, use a lint-free cloth and a small
amount of a neutral or slightly alkaline cleaning
agent.
► After cleaning, wipe over with fresh water.

Major Maintenance
5.2.2 Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 49
5.2.2.5
5.2.2.5 Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the Protective Covers
Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the Protective Covers
► Open the protective covers.
► Wipe the sliding surfaces of the gas pressure shock
absorbers clean with a lint-free cloth.
► Open and close the cover several times in succes-
sion.
► No oil should be visible on the piston. Otherwise, the
gas pressure shock absorbers must be replaced by
authorized personnel. For removal and installation
details, read the service manual for your machine.
► Open the protective cover.
► Pull the protective cover approx. 30 cm horizontally
towards you and then release it again.
If the cover does not open completely again, the gas
pressure shock absorbers must be replaced by au-
thorized personnel.
For removal and installation details, refer to the ser-
vice manual for your machine.
► Pull the protective cover vertically to a position be-
tween the top and bottom positions and then release
it again.
The cover must either stay in position without help or
open a bit further. If it closes on its own, the gas pres-
sure shock absorbers must be replaced by author-
ized personnel.
For removal and installation details, read the service
manual for your machine.
► Close the protective cover.
► Repeat these steps for all protective covers.

Major Maintenance
Maintenance Tasks for Base Machine 5.2.3 Final Work
50 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
5.2.2.6
5.2.2.6 Checking the Guide Rollers on the Protective Covers
Checking the Guide Rollers on the Protective Covers
5.2.2.7
5.2.2.7 Checking the Buffers on the Protective Covers
Checking the Buffers on the Protective Covers
5.2.3
5.2.3 Final Work
Final Work
► Reestablish the compressed air supply to the machine.
► Check the guide roller (1) for damage. If the guide
roller is damaged, it must be replaced by authorized
personnel. For adjusting the flap cover and for other
information, read the Service manual.
► Check the O-rings (2) on the guide roller. If the O-
rings are damaged or missing, they must be replaced
by authorized personnel. For removal and installation
details, read the Service manual.
► Repeat these steps for all guide rollers (two per cov-
er).
► Pull the protective cover completely downwards.
► Check if the roller (2) touches the lower buffer (1) in
the guidance.
► If the roller touches the buffer, the buffer has to be re-
placed by authorized personnel. For adjusting the
flap cover and for other information, read the Service
manual.
► Repeat these steps for all buffers (two buffers per
protective cover).