Head Reconfiguration Kit 2 Assembly Instructions Head Reconfiguration Kit CPP fo r the SIPLACE X Ser ies Issue 03/2010 2.7 Installing the CPP Placement H ead 99 2.7.4.5 Connections at the Compressed Air Distributor 2 2 D…

2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series Head Reconfiguration Kit
2.7 Installing the CPP Placement Head Issue 03/2010
98
2.7.4.4 Settings of the Head Interface Board C500
X Check the jumper settings on the head interface board C500:
2
X In case of CAN bus problems, measure the resistance between pin 7 (CAN High) and pin 2
(CAN Low). It should be 60 Ohm.
2
Jumper Gantry 1 Gantry 2 Gantry 3 Gantry 4
1 0 1 0 1 Gantry ID0
2 0 0 1 1 Gantry ID1
3 1 1 1 1 120 Ohm CAN terminating resistor
4 0 0 0 0 Boot
5 0 0 0 0 Reset
6 0 0 0 0 CAN-ID0
7 0 0 0 0 CAN-ID1
8 0 0 0 0 Write protection released
Position of
the jumpers

Head Reconfiguration Kit 2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series
Issue 03/2010 2.7 Installing the CPP Placement Head
99
2.7.4.5 Connections at the Compressed Air Distributor
2
2
Designation Item no.
Plug QSC-6H 00337891-xx
Plug QSC-4H 00330249-xx
Plug QSC-8H 03010908-xx
Plug QSC-10H 00324874-xx
Plug QSC-12H 03015210-xx
Rear view of the pneumatic distribu
-
tor
Input:
7 fold flat tube (PK 6)
2 fo ld pn eumatic tu be ( vacuum
pump option PK10
not for CPP head and TwinHead)
Front view of the pneumatic distribu
-
tor
Output:
CPP head
Holding circuit 2
Pressure control valve / retract cylinder 2

2 Assembly Instructions Head Reconfiguration Kit CPP for the SIPLACE X Series Head Reconfiguration Kit
2.7 Installing the CPP Placement Head Issue 03/2010
100
X Connect all compressed air hoses
2.7.5 Replacing the Servo Cards
X Open the door of the servo unit with the machine key.
X Insert the servo cards according to your machine configuration. (See Section 2.9.1 "Configu-
ration Axis Unit A364" on page 124.)
Connecting the compressed air hoses
NOTE:
When switching between C&P20, CPP and DLM C&P6/C&P12, the servo amplifier
SDS120/2,5S1 [00353445-xx] can be kept. 2
When switching between C&P20 and CPP, the DC/DC converter [03002397-xx] can be
kept. 2
When switching between C&P20 and CPP, only the Z axis servo card must be replaced.2
C&P20A: SDS60/2.5Z1 1 [03002143-xx] 2
CPP: SDS120/1.5Z2 1 [03070900-xx] 2