PROFLOW MODULE CALIBRATIONS Chapter Issue 16, Nov 18 T echnical Reference Manual 11.17 ‘ProFlow T ransfer Material Level set to Full: 100% ’ 42. Select Exit . 43. Select Exit . 44. Select Exit . 45. Select Back .

PROFLOW MODULE
CALIBRATIONS
11.16 Technical Reference Manual Chapter Issue 16, Nov 18
11. Select Classic Calibrations.
12. Select ProFlow.
13. Select Transfer Material.
14. Select Set Empty.
15. The following message is displayed:
‘Confirm: Transfer head is fitted and empty?’
16. Select Confirm.
17. If prompted confirm that the correct stencil is fitted.
18. If prompted confirm that the correct ProFlow head size is fitted.
19. The following message is displayed:
‘The ProFlow unit will be placed at the rear of the image’
20. Select Confirm.
21. If prompted confirm that the ProFlow cover plate is removed.
22. The following messages are displayed:
‘Reading ProFlow Transfer Material Level...’
‘ProFlow Transfer Material Level set to Empty: 0%’
23. Select Change ProFlow.
24. ProFlow rises to the Home position.
25. If prompted confirm that the ProFlow base cover is fitted.
26. The print carriage moves to the front of the machine.
27. Open the printhead cover.
28. Remove the empty transfer head from the ProFlow pressure mechanism.
29. Fit a full transfer head to the ProFlow pressure mechanism.
30. Remove the cover.
31. Close the printhead cover.
32. Press the System button.
33. Select Continue.
34. If prompted confirm correct stencil is fitted.
35. If prompted confirm correct ProFlow head size is fitted.
36. The following message is displayed:
‘The ProFlow unit will be placed at the rear of the image’
37. Select Confirm.
38. Confirm ProFlow cover removed.
39. Select Set Full.
The message ‘Confirm: Transfer head is fitted and full?’ is displayed.
40. Select Confirm.
41. The following messages are displayed:
‘Reading ProFlow Transfer Material Level...’

PROFLOW MODULE
CALIBRATIONS
Chapter Issue 16, Nov 18 Technical Reference Manual 11.17
‘ProFlow Transfer Material Level set to Full: 100%’
42. Select Exit.
43. Select Exit.
44. Select Exit.
45. Select Back.

PROFLOW MODULE
CALIBRATIONS
11.18 Technical Reference Manual Chapter Issue 16, Nov 18