AN353423548483en-000201.pdf - 第5页

10 10.1 10.2 10.3 10.4 11 11.1 11.2 11.3 11.4 11.5 Network Design 34 Star Topology 34 Line Topology 34 Ring Topology 35 Combined Topologies 35 Specifications 37 Connections 37 Settings 37 Network 37 Power 37 Certificatio…

100%1 / 38
6
6.1
6.2
6.3
6.4
7
7.1
7.1.1
7.1.2
7.1.2.1
7.1.2.2
7.1.2.3
7.1.3
7.1.3.1
7.1.3.2
7.1.3.3
7.1.3.4
7.1.3.5
7.2
7.2.1
7.2.2
7.2.2.1
7.2.2.2
7.2.2.3
7.2.3
7.2.3.1
7.2.3.2
8
8.1
8.2
8.2.1
9
9.1
9.2
9.3
Operation 19
Requirements for Successful Operation 19
Device Classification 19
Ensuring Safe and Successful Control 19
Feedback LEDs 19
Messaging 20
Implicit Messaging (Cyclic Operation) 20
Assembly Objects 18
Control Commands (Assembly Instance 104d) 20
Bytes 0–1: Command 20
Bytes 2–3: Reserved 20
Command Examples 20
Status Information (Assembly Instance 154d) 21
Bytes 0–1: Starter State 21
Bytes 2–3: Reserved 22
Bytes 4–7: Motor Current 22
Bytes 8–9: Trip Code 22
Bytes 10–11: Reserved 22
Explicit Messaging (Acyclic Operation) 22
Identity Object (Class 0x01) 22
Vendor-specific Objects 22
Class 100 ~ 102 Objects (Read/Write) 22
Class 103 Objects (Read Only) 23
Class 104 Objects (Read Only) 24
Supported Services for Vendor-specific Objects 25
Service Codes for Acyclic Operation 25
Status Codes for Acyclic Services 25
Attributes 26
Trip Codes 26
Parameter Lists 27
Parameters, Class 100, Class 101, and Class 102 Objects (Read/Write) 28
Ground Fault Protection 33
Overview 33
Connect the CT to the Ground Fault Inputs 33
Configure Ground Fault Protection Settings 33
AN353423548483en-000201/130R09454 | Danfoss A/S © 2022.10
Contents
EtherNet/IP Card
Installation Guide
10
10.1
10.2
10.3
10.4
11
11.1
11.2
11.3
11.4
11.5
Network Design 34
Star Topology 34
Line Topology 34
Ring Topology 35
Combined Topologies 35
Specifications 37
Connections 37
Settings 37
Network 37
Power 37
Certification 37
AN353423548483en-000201/130R0945 | 5Danfoss A/S © 2022.10
Contents
EtherNet/IP Card
Installation Guide
-
-
-
1 Safety
1.1 Disclaimer
The examples and diagrams in this manual are included solely for illustrative purposes. The information contained in this manual is
subject to change at any time and without prior notice. Responsibility or liability is never accepted for direct, indirect, or consequen-
tial damage resulting from the use or application of this equipment.
1.2 Warnings
W A R N I N G
SHOCK HAZARD
Attaching or removing accessories while the soft starter is connected to mains voltage may cause personal injury.
Before attaching or removing accessories, isolate the soft starter from mains voltage.
W A R N I N G
RISK OF PERSONAL INJURY AND EQUIPMENT DAMAGE
Inserting foreign objects or touching the inside of the soft starter while the expansion port cover is open may endanger person-
nel and can damage the soft starter.
Do not insert foreign objects in the soft starter with the port cover open.
Do not touch the inside of the soft starter with the port cover open.
AN353423548483en-000201 / 130R09456 | Danfoss A/S © 2022.10
Safety
EtherNet/IP Card
Installation Guide