6-1 Tg1357-ID-SO 0703-003 6. Data 6.1 Pattern Program 6.1.1 Placement Feeder Location Data It must be specified on which feeder No. (Fdr . No.) of the feeder base the flux dispensing unit should be installed. Rear Side of …

100%1 / 83
5-8
Tg1357-ID-SO
0703-003
[9] [Recog Dsp setup] Button
When this button is pressed, the following window opens, enabling the
operator to specify a graphic desplay mode for the recognized image,
depending on whether the results of a recognition operation are normal
or abnormal.
Fig.17 "Display Mode" Window
[Cross] :
When this is selected and the results of a
recognition operation are normal, a cross-
hair appears at the center of the recognized
object.
[Circle] :
When this is selected, a circle appears on
the recognized object.
[Outside] :
When selected, this displays the outline of
the recognized object.
[Noz Outside] :
When selected, this displays the vacuum
nozzle that was used to recognize a
component.
[Detect Pos] :
When selected, this displays the detection
position and area.
[Set Default] :
When pressed, this button sets the defaults.
When several display types (multiple selection possible) are selected
and the [OK] button is pressed, the specified types (modes) are saved.
When the [Cancel] button is pressed, the selection is canceled.
5.2 Component Recognition Test
6-1
Tg1357-ID-SO
0703-003
6. Data
6.1 Pattern Program
6.1.1 Placement Feeder Location Data
It must be specified on which feeder No. (Fdr. No.) of the feeder base the
flux dispensing unit should be installed.
Rear Side of Machine
Front Side of Machine
Feeder Base #3
Feeder Base #4
Feeder Base #2
Feeder Base #1
Unit #4
Unit #3
Unit #2
Unit #1
Fig. 18 Positional Relation between Feeder Bases and Flux Dispensing Units
Note
Up to 4 flux dispensing units can be installed on one feeder base.
6. Data
6-2
Tg1357-ID-SO
0703-003
Open the "Feeder Base #1" tab sheet in the "Placement Feeder Location" tab
sheet.
Press the icon ( ) and then icon ( ) to open the "Feeder Base" tab
sheet and edit the "Feeder Base" data.
Note
As for Feeder Bases #2 and #3, follow the same procedure to open the cor-
responding tab sheets.
[3]
[2]
[1]
Fig. 19 "Feeder Base #1" Tab Sheet
[1] Flux Unit Nos. 1 to 4
Reload Method
Select the flux reload method from "Manual" and "Automatic".
Note
In this unit, select "Manual".
Reload Time [sec]
Set the flux reload time period.
Memb. Thkns [mm]
Set the coating thickness.
Classification
Set the flux type used in the flux dispensing unit.
No. of Rot. [rot.]
Specify the rotational speed of the drum (rotational disk).
Data Input Range: 0.5 to 5 [Rotations]
Dispensing Position X,Y[mm]
Set the dispensing position offset values.
6.1 Pattern Program