OM-1352-003_w.pdf - 第73页
9-2 Tg1357-ID-SO 0703-003

9-1
Tg1357-ID-SO
0703-003
9. Troubleshooting
9.1 Starting Guidance
Table 8
Machine Information
Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
013901 Flux spread equipment un-carrying (rear).
Please set the flux spread equipment (rear) used by the pattern program.
013A01 Flux spread equipment un-carrying (front).
Please set the flux spread equipment (front) used by the pattern program.
9.2 Error IDs and Remedial Procedures
9.2.1 Others
Table 9
Error ID Error Name, Description, Cause, and Remedy
4b1001 Flux spread error
The flux spread was not completed within prescribed time.
Please remove and check flux spread equipment.
4b1002 Flux spread equipment error
Motor alarm was generated.
Please remove and check flux spread equipment.
9.2.2 Automatic Operation Error
Table 10
Error ID Error Name, Description, Cause, and Remedy
510c01 Auto Run Error
Comp. Missing (Recog.)
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
9. Troubleshooting

9-2
Tg1357-ID-SO
0703-003

10-1
Tg1357-ID-SO
0703-003 (M806WFX--0102)
10. Material
10. Material
10.1 Electrical Circuit Diagrams
Flux Dispensing Unit Circuit Diagram
Drawer Connector for Feeder
GXH Main Body Side
Connection Confirmation Signal [OUT]
Not Used
(Feeder Base)
Feeder Power
Distribution
Feeder Base I/O
Feeder Base Serial
Communications
Feeder Power
Distribution
Feeder Base I/O
Feeder Base Serial
Communications
(Feeder Base)
Drawer Connector for Feeder
Rotation Start
Alarm Reset
Driver Alarm
Communications
Ready
Feeder Connec-
tion Check
Not Used
Not Used
Rotation Detection
Remainder Detection
Feeder Connec-
tion Check
Rotation Detection Sensor
Flux Transfer Device
Servoamplifier
Lane 1 Feed Command [IN]
Lane 2 Feed Command [IN]
Ready Signal [OUT]
Connected Check Signal
(For Communications Confirmation) [OUT]