OM-1352-003_w.pdf - 第53页

6-4 Tg1357-ID-SO 0703-003 Component ID Component IDs can be specified in each text box. When one of the unit No. buttons ([Unit #1] through [Unit #4] buttons) is selected, the corresponding dispensing unit No. is displaye…

100%1 / 83
6-3
Tg1357-ID-SO
0703-003
[2] [Unit #1] through [Unit #4] Buttons
Select the flux dispensing unit to be used.
When a flux dispensing unit is selected, the ID is displayed in the text
box entitled "Component ID".
[3] List of Placement Feeder Location Data
Set the flux spreading unit to be installed on each feeder base.
Fdr No.
This indicates the feeder Nos. where flux dispensing units can be
arranged.
Note
Up to 5 feeder Nos. (Fdr Nos. equivalent to 5 lanes) can be used for
one feeder base.
x01
x49
2 1
25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
2 12 12 1
Connector on Feeder
Base Side
Connector on Flux Transfer
Device Side
Unit #4
<FLUX.UNIT #4>
Unit #3
<FLUX.UNIT #3>
Unit #2
<FLUX.UNIT #2>
Unit #1
<FLUX.UNIT #1>
Fig. 20 Example of One Feeder Base with Maximum Number of Flux Dispensing Units
2 1
4 3 2 1
x 49
25 24 23 22
2 1
For Blocks 1 and 4 For Blocks 2 and 3
Multi-Layer Tray Feeder
(JEDEC Size)
Multi-Layer Tray Feeder
(JEDEC Size)
Unit #1
Unit #1
x 01
Fig. 21 Multi-Layer Tray Feeder on Each Block
6.1 Pattern Program
6-4
Tg1357-ID-SO
0703-003
Component ID
Component IDs can be specified in each text box.
When one of the unit No. buttons ([Unit #1] through [Unit #4] buttons)
is selected, the corresponding dispensing unit No. is displayed like
"FLUX. UNIT #1" to "FLUX. UNIT #4".
C
Set a control command.
Notice
If a control command other than the following ones is used, the
step becomes invalid.
- (hyphen) :
This command handles the steps as those for the
placement feeder location data.
E : This command shows the end of the placement feeder
location data.
The step where "E" is set is valid.
S : This command invalidates the steps specified as
placement feeder location data.
X : This command invalidates the steps specified as
placement feeder location data and shows the end of
the data.
Comment
Set a comment for each Fdr No.
Up to 32 characters can be used.
Alphanumeric characters and symbols can be used.
Note
(a) The performance of the machine is not affected by these
commands. In other words, it has nothing to do with or without
these comments.
(b) It is recommended to set helpful information on components
related to the feeder Nos. (Fdr Nos.).
Feeder Fixed
Select "Enable" or "Disable" to determine whether or not the feeder
positions should be fixed in place.
When "Enable" is selected, the feeder Nos. (Fdr Nos.) and the
component IDs are not affected by any insert and delete operations of a
component.
Disable :
The feeder position is not fixed.
Enable : The feeder position is fixed.
6.1 Pattern Program
6-5
Tg1357-ID-SO
0703-003
Feeder Alternate
Select "Enable" or "Disable" to determine whether or not the feeder
alternate function should be used.
Disable :
The feeder alternate function is not used.
Enable :
The feeder alternate function is used.
Fdr No.
When "Enable" is selected for the feeder alternate function, set the
destination feeder No. (Fdr No.) of the feeder that will work in place of
the feeder where a component pickup error has occurred in succession.
Reference
Refer to "1.4 Placement Feeder Location Data" in "Chapter 3" of the
instruction manual (Vol. 3 for the main machine) for details.
Setting Procedure of Placement Feeder Location Data
Procedure
(1) Press the icon ( ) when the "Placement Feeder Location" tab sheet is
active. The "Feeder Base" subtab sheets become valid and can be used
to specify each flux dispensing unit.
(2) Select each unit No. button ([Unit #1] through [Unit #4] buttons) in the
required "Feeder Base #" subtab sheet.
(3) Specify parameters (number of rotations) in the "No. of Rot. [rot.]" text
boxes for the specified unit No.
6.1 Pattern Program