DeltaTherm IR Cure Module Revision C / Sept ember 2022 Page 16 of 41 Machine Safety Check 201B200B200B When the machi ne is started, it must initialize. After it has initializ ed successfu lly, the operator interf ace sh…

100%1 / 41
DeltaTherm IR Cure Module
Revision C / September 2022
5. 39B38B38BEnter your password as necessary, if in protected mode.
6. 40B39B39BOperate the system as necessary.
199B198B198B
6B6B6BFigure 7: Enter Password
Light Tower Operation
200B199B199BThree stacked indicator lights and a buzzer are used to show the machine status. The
lights are green, amber, and red. The buzzer is below the green light. The lights are visible
from all sides of the machine. The indicators operate as follows:
41B40B40BThe green light is on when the machine is in Auto Cycle and operates within
specified parameters. It is off at all other times.
42B41B41BThe amber light is on when the machine is in Auto Cycle but the specified
parameters have not been reached. It is off at all other times.
43B42B42BThe red light is on steady when the machine is not in Auto Cycle due to operator
intervention. It flashes when the machine is in cycle, but the cycle is stopped
because of a machine problem. It is off at all other times.
44B43B43BThe buzzer cycles when the red light flashes with machine errors. It also cycles
briefly when a board is at the end of the machine and must be unloaded (if the
offload alert option is selected in the Setup mode).
State
Red
Amber
Green
Buzzer
Cycle Stop
ON
OFF
OFF
OFF
Auto Cycle
OFF
ON
OFF
OFF
In Cycle
OFF
OFF
ON
OFF
Machine Error
FLASH
OFF
OFF
FLASH
7B7B7BFigure 8: Light Tower & Buzzer Status
DeltaTherm IR Cure Module
Revision C / September 2022
Machine Safety Check
201B200B200BWhen the machine is started, it must initialize. After it has initialized successfully, the
operator interface shows the following screen:
202B201B201B
8B8B8BFigure 9: PVA Screen
203B202B202BThe machine safety check ensures that the DeltaTherm IR Cure Module safety devices
(emergency stop, door interlocks, etc.) operate correctly. For the startup procedure, the
operator must start and complete the safety check successfully. After you start the safety
check, you must activate and deactivate the safety devices. Some safety checks are timed
and will cause a failure if the action is not done in the set time.
Shutdown Procedure
204B203B203BDo the following procedure to shut down the cure module.
1. 45B44B44BWait for all boards to clear the cure module.
2. 46B45B45BPress Auto Stop on the OIT. Wait for the PVA screen to appear.
3. 47B46B46BWait one minute for the module to cool. The exhaust fan will be on.
4. 48B47B47BTurn the main power switch to OFF.
5. 49B48B48BMake sure you remove all parts before you shut down the cure module.
273B272B272BCAUTION: If you plan to perform maintenance during the shutdown, be sure to lock
out and tag the machine.
DeltaTherm IR Cure Module
Revision C / September 2022
Cycle Stop
205B204B204B
9B9B9BFigure 10: Cycle Stop
206B205B205BOptions in Cycle Stop are: Auto Cycle, Manual, and Setup.
Select “F1or the auto cycle icon to operate the module in Auto Cycle.
Select “F3” or the manual icon to operate the module in Manual mode.
Select ESC or the settings icon to go to Setup mode and view or
change the operating parameters of the module.
Select the Home icon or “F3” from any mode to return to Cycle Stop.