DeltaTherm IR Cure Module
Revision C / September 2022
Rename Recipe
115B114B114BUse the arrows on the screen or the “F1” and “ESC” button to scroll to the Setup-
Settings screen.
224B223B223B
20B20B20BFigure 21: Setup - Rename Profile
116B115B115BUse the + - Page icons or the F2 and F4 keys to scroll through the recipe names.
117B116B116BYou can have a maximum of 30 profiles.
118B117B117BSelect the name you want to change in the text box.
119B118B118BThe keyboard will be shown, type the new name and select enter. The new name will
be saved. Recipe names are limited to 15 characters.
DeltaTherm IR Cure Module
Revision C / September 2022
Global Settings
225B224B224B
21B21B21BFigure 22: Global Settings
1. 120B119B119BPress Unit Selection to toggle between Metric and Standard.
2. 121B120B120BPress Process Timeout to enable or disable board process timeout in Auto Cycle.
3. 122B121B121BPress Clear Board to enable or disable the clear board check when entering Auto
Cycle. If disabled, upon entering Auto Cycle, boards in the oven will not move
downstream until the oven is at temperature and ready to process boards.
4. 123B122B122BPress Auto Idle Timeout to enable or disable the idle timeout in Auto Cycle. When
enabled, if no boards are being processed in the specified timeout, a silent timeout
fault will occur and the oven will exit Auto Cycle, turning the heater panels off.
5. 124B123B123BPress Conveyor Width to enable/disable the conveyor width move to current recipe
position after homing and when entering Auto Cycle.
DeltaTherm IR Cure Module
Revision C / September 2022
Fault Recovery Procedure
226B225B225BSeveral errors can cause a fault condition. They are:
125B124B124BThe EMERGENCY STOP is engaged or there is an open door
126B125B125BThere is an exhaust or intake fan failure
127B126B126BThe parameters are out of range
128B127B127BThe module is over-temperature
129B128B128BThere is a solid-state relay failure
227B226B226BThe following sections show an example of a machine error. For a complete list of error
messages, refer to Section 11.
Recovery from Emergency Stop or Open Door Error
228B227B227BIf the Emergency Stop button is engaged or the machine has a system error, perform the
following procedure to return the machine to the cycle stop state.
285B284B284BWARNING: If the Emergency Stop was engaged because of system failure, do not
disengage the Emergency Stop. Shutdown the system and have qualified personnel
repair the machine.
1. 130B129B129BDisengage the Emergency Stop button or close all doors.
2. 131B130B130BSelect “Clear Fault”.
Recovery from an Exhaust or Intake Fan Failure
1. 132B131B131BSelect “Clear Fault” to stop the alarm or “Reset” to clear the fault.
2. 133B132B132BOperate the fan in Manual mode to make sure the components operate correctly.
Recovery from a Parameter Out of Range Error
1. 134B133B133BSelect “Silence Horn” to stop the alarm or “Clear Fault” to clear the fault.
2. 135B134B134BOperate the module in manual mode or restart the Auto Cycle. Look for the
parameter that causes the error.
3. 136B135B135BIf the error continues to repeat, refer to Section 12.