DeltaTherm_IR_REV_C.pdf - 第23页
DeltaTherm IR Cure Module Revision C / Sept ember 2022 Page 23 of 41 Sensors 216B215B215B The PIP Sensors can be monitor ed in Manual mode for corr ect operation. 217B216B216B 15B15B15B Figure 16 : Sensors in Manual Mod …

DeltaTherm IR Cure Module
Revision C / September 2022
Page 22 of 41
214B213B213BThe Conveyor Width can be set in Manual mode.
1. 80B79B79BPress to manually enter the target conveyor width setpoint.
• 81B80B80BTouch the screen and a keypad will be shown.
• 82B81B81BEnter the necessary value.
• 83B82B82BPush ‘ENT’, and the zone screen will be shown again.
2. 84B83B83BPress to move the current target conveyor width setpoint.
276B275B275BNote: Prior to the move, the machine will check for any boards.
3. 85B84B84BPress to rehome the conveyor width.
277B276B276BNote: Prior to the move, the machine will check for any boards.
Conveyor Jog
215B214B214B
14B14B14BFigure 15: Conveyor Jog in Manual Mode
1. 86B85B85BThis screen displays the current conveyor width.
2. 87B86B86BPress to adjust the conveyor width. This will jog the conveyor width in a positive or
negative direction.
278B277B277BNote: The clearboard sequence will not run prior to the jog.

DeltaTherm IR Cure Module
Revision C / September 2022
Page 23 of 41
Sensors
216B215B215BThe PIP Sensors can be monitored in Manual mode for correct operation.
217B216B216B
15B15B15BFigure 16: Sensors in Manual Mode
279B278B278BNote: Process PIP will only show on 12 ft and 16 ft oven length systems.
SMEMA Control
1. 88B87B87BThe SMEMA inputs (Upstream Board Available and Downstream Ready) can be
monitored for correct operation through the SMEMA screen in Manual mode.
2. 89B88B88BSelect the necessary output (Machine Ready and Board Available) to toggle it on or
off.
218B217B217B
16B16B16BFigure 17: SMEMA in Manual Mode

DeltaTherm IR Cure Module
Revision C / September 2022
Page 24 of 41
Setup Mode
219B218B218BIn Setup mode, the operator can set basic functions of the machine and Auto Cycle
parameters. These parameters (depending on the machine) are the current recipe, IR panel
temperatures, allowable deviations, conveyor width, and conveyor speed. Parameters are
saved in the controller under the current recipe even when the module is shut down. Push
the Home button or the F3 button at any time to exit Setup mode and return to cycle stop.
IR Panels
220B219B219B
17B17B17BFigure 18: Setup Zone 1 Panels
1. 90B89B89BThe Heater Panel Recipe Switch can disable or enable the use of a zone’s upper or
lower heater panel in Autocycle. If enabled, the panel will display a green
checkmark . If disabled, the panel will display a red X .
280B279B279BNote: IR panels cannot activate unless the exhaust fan is on.
2. 91B90B90BThe Setpoint box is the target temperature (display temperature is filtered) for
each zone and the deviation box is the permitted deviation from the setpoint for
that zone.
• 92B91B91BTouch the Setpoint box and a keypad will be shown.
• 93B92B92BEnter the necessary value. The system minimum and maximum are shown
below the numeric field.
• 94B93B93BPress “ENT” to save the value and close the keypad.