26 6. TRO UBLE SHO OTING 1. The System cannot R eset af ter Booting. Emergency swit ch erro r ⚫ Check the Emer gency switch is not pressed, by mistak e. 2. Z axis or X and Y axis c annot be Positioned Accurately in Pr oc…

100%1 / 28
25
5.3 Syringe Mounting Bracket – Attachment
From the main screen, on the teaching pendant,
press 4. Use the jog keys to move the head into
a central position and lower head until there is
sufficient access to the rear of the bracket. Use
SHF button to change movement speed. Follow
instructions below.
1. Move and lower head using teaching
pendant.
2. Remove mounting plate.
4. Attach attach top bracket.
3. Secondary plate should be exposed
5. Attach bottom bracket from behind.
6. Install syringe and lightly tighten thumb
screws.
26
6. TROUBLE SHOOTING
1. The System cannot Reset after Booting.
Emergency switch error
Check the Emergency switch is not pressed, by mistake.
2. Z axis or X and Y axis cannot be Positioned Accurately in Processing
1) Loss of steps will cause inaccurate positioning phenomenon.
Overload, excessive speed or acceleration, insufficient power supply, or mismatched motor drive would lead to
the loss of steps. Please check the overload and the parameters settings. If the inaccurate positioning
phenomenon disappears or remits after reducing the speed or acceleration, we can make sure the phenomenon
is caused by the motor loss of steps. If inaccurate positioning phenomenon is very obvious for one axis, reduce
the acceleration of the axis.
2) Operation Error will cause inaccurate positioning phenomenon.
Do not reset when the work done
Make the system reset automatically after each accumulated processing error has been eliminated,)
7. WARRANTY
Manufacturer warrants this product to the original purchaser for a period of one (1) year from date of purchase to
be free from defects in material and workmanship, but not against damages by misuse, negligence, accident, faulty
installations and instructions. Manufacturer will repair or replace (at factory’s option), free of charge, any
component of the equipment thus found to be defective, on return of the component, “PREPAID” to the factory
during the warranty period. In no event shall any liability or obligation of the Manufacturer arising from this
warranty exceed the purchase price of the equipment. This warranty is only valid if the defective product is returned
as a complete assembly without physical damage. The Manufacturers liability, as stated herein, cannot be altered
or enlarged except by a written statement signed by an officer of the company. In no event shall the Manufacturer
be liable for consequential or incidental damages. A return authorization is required from Techcon Systems prior
to shipping a defective unit to the factory.
Manufacturer reserves the right to make engineering product modifications without notice.
All returns must be issued with a Returns Authorization number, prior to return. Send warranty returns to:
Techcon Systems Corporate Headquarters,
10800 Valley View Street, Cypress, 90630, USA.
Tel: 1-714-230-2398, Fax: 1-714-828-2001
E-mail: oemorders@okinternational.com
Techcon Systems European Corporate Office,
Eagle Close, Chandlers Ford Industrial Estate,
Eastleigh, Hampshire, SO53 4NF, UK.
Tel: +44 2380 489 100, Fax: +44 2380 489 109
E-mail: europe-orders@okinternational.com
Or visit www.techcon.com
27
8.
Manufacturer: Dover (Shenzhen) Industrial Equipment Manufacturing Co., Ltd
4
Floor West, 1 Building, Tingwei Industrial Park,
6 Liufang Road, Boa’an District,
Shenzhen, China
Manufacturer Contact: OK International Ltd.
Ian Jennings
Chandlers Ford, Hampshire Tel: +44 (0) 23 8048 9000
England SO53 4NF Fax: +44 (0) 23 8048 9109
Declares that the product(s): Industrial Robot/Bench-top Robot
Model Numbers: TSR2201, TSR2301, TSR2401
Option Kit Model Numbers:
TSR2200-SC
TSR2300-SC
TSR2400-SC
Is intended to be incorporated into machinery or to be assembled with other machinery to
constitute machinery covered by Directive 2006/42/EC.
And that the following harmonized standards and specifications have been used:
EN ISO 10218-1:2011
EN ISO 12100:2010
EN 60204-1/A1:2009
And furthermore declares that the product(s) covered by this Declaration must not be put into
service until the machinery into which it is to be incorporated or of which it is a component
has been found and declared to be in conformity with the provisions of directive 2006/42/EC.
Signature: Date: May 23
rd
, 2014
Jimmy Guo
Quality Engineer
Manufacturers Declaration of Incorporation
Directive: Machinery Directive 2006/42/EC