00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第108页
Service Work PCB conveyor system 4.3.14 Replac ing the Proximity Switch for th e Adjustment Unit [03040795-xx] 108 Service Manual SIPLACE D1/D1i/D2/D2i The switching point is set at the actuator on the conveyor edge: ► P…

Service Work
4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to modular PCB conveyor only) PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 107
4.3.14
4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to modular PCB conveyor only)
Replacing the Proximity Switch for the Adjustment Unit [03040795-xx] (applicable to
modular PCB conveyor only)
Overview
The proximity switch serves as a signal for controlling the pneumatic valve of the adjustment unit. Once
the switching point has been reached, the conveyor edge is connected via the short-stroke cylinder.
Removal/Installation
Parts
▪ Proximity switch for adjustment unit 1 and 2
[03040795-xx]
Legend
1. Adjustment unit 1
2. Adjustment unit 2
3. Transport direction
► Move the PCB conveyor to the position which gives
you best access to the adjustment system.
► Move the Y gantries into the area outside the PCB
conveyor.
► Switch off the machine and secure it to prevent unau-
thorized reactivation.
► Switch off the compressed air supply.
► Loosen the grub screw on the clamping device (1)
and unthread the connection cable as far as the con-
version board of the assembly tub.
► Fit the new proximity switch and reconnect the sys-
tem to the electrical system.
► Fix the proximity switch with the grub screw.
► Tighten the grub screw to a torque of 20 Ncm
(+3 Ncm). The proximity switch must be level with the
adjustment unit housing (2).

Service Work
PCB conveyor system 4.3.14 Replacing the Proximity Switch for the Adjustment Unit [03040795-xx]
108 Service Manual SIPLACE D1/D1i/D2/D2i
The switching point is set at the actuator on the conveyor
edge:
► Position the adjustment unit, with the help of the width
adjustment belt, so that the proximity switch can be
easily accessed.
► Place a 4/10mm distance gauge on the adjustment
unit and press this distance gauge against the adjust-
ment unit.
► Push the proximity switch upwards, as far as the stop
and tighten the fastening screw.
NOTICE!
Perform a width adjustment function test at all conveyor
sides.
► Use the SITEST program to calibrate the conveyor
edges.

Service Work
4.3.15 Replacing the Light Barriers for Transmitter and Receiver Modules [03039283] PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 109
4.3.15
4.3.15 Replacing the Light Barriers for Transmitter and Receiver Modules [03039283]
Replacing the Light Barriers for Transmitter and Receiver Modules [03039283]
4.3.15.1
4.3.15.1 Replacing the Transmitter
Replacing the Transmitter
► Dismantle the holder and the transmitter.
► Unscrew the transmitter from the holder.
► Unthread the connection cable as far as the relevant plug in the conveyor edge.
► Unplug the connector plug.
► Rerun the connection cable accordingly and reconnect the plug on the conveyor edge to the electri-
cal system.
► Fix the new light barrier in the original position.
Parts
Please note the different item numbers for the individual
light barriers - these are for the different lengths of the
connection cable.
Legend
1. Transmitter at input conveyor [03039283-xx]
2. Receiver at input conveyor [03039269-xx]
3. Transmitter at placement area [03039284-xx]
4. Receiver at placement area [03039270-xx]
5. Transmitter at output conveyor [03039285-xx]
6. Receiver at output conveyor [03039271-xx]
▪ T = transport direction
NOTICE
Important instructions for replacing the light barrier
► When looking in the direction of transport, the transmitter is always on the left.
► Check whether it would be helpful to feed in the new cable with the aid of the old one, at
least in some areas.