Service Work C&P6/12 Head 4.4.24 R eplacing the Membrane (Vacuum Plate) on the Sleeve [03037984- xx] 158 Service Manual SIPLACE D1/D1i/D2/D2i 4.4.24 4 . 4 . 2 4 R e p la c in g t h e M e m b r a n e ( V a c u u m P l…

Service Work
4.4.22 Press Fit Connections with Fixture Clips on the Vision Board (D Series) C&P6/12 Head
Service Manual SIPLACE D1/D1i/D2/D2i 157
4.4.22
4.4.22 Press Fit Connections with Fixture Clips on the Vision Board (D Series)
Press Fit Connections with Fixture Clips on the Vision Board (D Series)
4.4.23
4.4.23 Replacing the Raceway (Circular Arc Guide)
Replacing the Raceway (Circular Arc Guide)
CAUTION
Do not damage the fixture clips!
To disconnect the component and PCB camera connections, you need to open the fixture clips
by applying pressure to the side of the connector.
The adjacent diagram shows the press-fit connections for
the component camera (1) and the PCB camera (2) on
the Vision board of the SIPLACE D1/D2. Each of the two
positions has two connectors of different sizes with fixture
clips.
➢ To release the press-fit connections, press the con-
nector sides together at the top, with your thumb and
index finger.
► The fixture clips will open and the connector can be
pulled up and off.
⇨ The adjacent diagram shows the two press-fit con-
nections arranged one above the other, for the
Vision
signals
(small connector) and
illumination control
(large connector) after disconnection of the connec-
tors.
NOTICE
SIPLACE Service
This service task may only be performed by specially trained SIPLACE service technicians. The
procedure is described in a separate manual.

Service Work
C&P6/12 Head 4.4.24 Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
158 Service Manual SIPLACE D1/D1i/D2/D2i
4.4.24
4.4.24 Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
The sealing membrane on the sleeves ensures sufficient vacuum by sealing the tip of the nozzle (serves
as the air inlet) in the sleeve.
Tools and equipment
▪ Standard tool
▪ Spare part: membrane (vacuum plate) [03037984-xx]
Removal
► Loosen the old membrane with an Allen key (1.5 mm) and remove the membrane.
Installation
► Fit the new membrane onto the sleeve and tighten the membrane with an Allen key.
4.4.25
4.4.25 Replacing the Vacuum Hoses on the C&P Head
Replacing the Vacuum Hoses on the C&P Head
The length of the vacuum hoses and the way in which they are fitted has been improved to ensure that,
when the hoses are replaced - especially in SX, DX, X, D3 and HF machines - these hoses can be run
in a manner which will not interrupt the vacuum supply.
Tools and equipment
▪ Standard tool
▪ Spare part: vacuum hoses and guidance [03064147-xx]
Contents:
– Hose for placement circuit query (new length: 180 mm, old length: 190 mm) [03002187-02]
– Hose for holding circuit query (new length: 225 mm, old length: 200 mm) [03002188-02]
– Hose for placement circuit / 3x6x145 (new length: 145 mm, old length: 125 mm) [03010444-02]
– Hose for hold circuit / 4x7x140 [03010445S01]
– Hose guide [03048807-01]
– Cylinder screw M3x6 DIN912-A2 [03045028-01]
Blue membrane for the sleeve with ball fixing C&P6/12
(old version [00354244-xx])
White membrane for the sleeve with ball fixing C&P6/12,
made of an alternative material
(new version [03037984-xx])
CAUTION
Do not use a ball Allen key!
► Make sure that you do not use a ball Allen key.

Service Work
4.4.25 Replacing the Vacuum Hoses on the C&P Head C&P6/12 Head
Service Manual SIPLACE D1/D1i/D2/D2i 159
Removal/installation
► Mark the connection points and the route of the individual hoses, so that these can be rerun correctly
later on.
► Disconnect the hoses from the vacuum generator and the vacuum measuring board.
► Fit the additional hose guide (M3 screw) on the top measuring hose duct.
► Fit the new hose as shown in the diagrams.